Important Model Verification
GoodWe's official ES Uniq product page and current manufacturer datasheet list the 8kW model as GW8000-ES-C10. The name GW8000M-ES-C10 appears on some Pakistan-based seller listings, but the āMā suffix was Not Verified in GoodWe's official model list. This report and the product artwork therefore use the manufacturer-verified model number GW8000-ES-C10.
Product Identification
| Field | Value | Verification |
|---|---|---|
| Brand | GoodWe | Official manufacturer source |
| Product series | ES Uniq | Official manufacturer source |
| Official model | GW8000-ES-C10 | Official manufacturer datasheet |
| Seller alias | GW8000M-ES-C10 | Seller supplied; manufacturer Not Verified |
| Product type | Low-voltage hybrid solar inverter | Official manufacturer source |
| Phase | Single phase | Official manufacturer source |
| Nominal output | 8.0kW | Official manufacturer datasheet |
Shopify Product Title
GoodWe GW8000-ES-C10 8kW Hybrid Solar Inverter
Short Description
The GoodWe GW8000-ES-C10 is an 8kW single-phase low-voltage hybrid inverter from the ES Uniq series. It supports up to 16kW PV input, a 48V battery system, two MPPT trackers, generator integration, backup operation and WLAN/app connectivity. Its IP66 enclosure supports demanding installation environments. Battery compatibility and site suitability must be confirmed by a qualified installer.
Full Product Description
The GoodWe ES Uniq GW8000-ES-C10 combines solar generation, battery storage, grid interaction and backup power control in one single-phase hybrid inverter. Its 8kW nominal AC output is paired with up to 16kW maximum PV input. Two MPPT trackers use a 2/1 string arrangement, with manufacturer-specified input-current limits of 32A and 16A respectively.
The inverter uses a 48V low-voltage battery architecture and supports lithium-ion and lead-acid battery categories within the stated 40ā60V range. Maximum continuous charge and discharge current is 160A, with up to 8kW charging power and 8.8kW discharging power. Battery model, BMS communication and operating settings must be verified before commissioning.
For backup applications, the ES Uniq series provides a transfer time of less than 4ms. The GW8000-ES-C10 delivers 8kVA nominal backup power and up to 8.8kVA without the grid, with a stated 16kVA capability for 10 seconds. A 3-in-1 port supports generator, smart-load and on-grid inverter functions, subject to correct system design and configuration.
Professional design and installation are mandatory. PV string voltage, battery capacity, earthing, protection equipment, cable sizing, generator settings, grid approval and backup loads must be checked for the actual site.
Key Features
- 8.0kW nominal single-phase AC output
- Up to 16.0kW maximum PV input
- Two MPPT trackers
- 2/1 PV string arrangement
- 48V nominal low-voltage battery system
- 40ā60V battery operating range
- Up to 160A continuous battery charge/discharge current
- Up to 8.8kW maximum AC active power
- Maximum efficiency up to 97.6%
- Less than 4ms backup transfer time
- Generator and smart-load support through the 3-in-1 port
- IP66 enclosure rating
- WLAN and GoodWe app connectivity
- Supports compatible on-grid and off-grid parallel operation
Technical Specifications
PV Input
| Specification | GW8000-ES-C10 |
|---|---|
| Maximum PV input power | 16,000W |
| Maximum PV input voltage | 600V DC |
| MPPT operating voltage range | 60ā550V DC |
| Start-up voltage | 58V DC |
| Nominal PV input voltage | 360V DC |
| Number of MPPT trackers | 2 |
| PV strings per MPPT | 2 / 1 |
| Maximum input current per MPPT | 32A / 16A |
| Maximum short-circuit current per MPPT | 48A / 24A |
| Maximum current per individual string | 16A |
Battery
| Specification | GW8000-ES-C10 |
|---|---|
| Supported battery categories | Lithium-ion / lead-acid |
| Nominal battery voltage | 48V DC |
| Battery voltage range | 40ā60V DC |
| Battery start-up voltage | 44.2V DC |
| Number of battery inputs | 1 |
| Maximum continuous charge current | 160A |
| Maximum continuous discharge current | 160A |
| Maximum charging power | 8.0kW |
| Maximum discharging power | 8.8kW |
| BMS communication | CAN |
Grid Output and Input
| Specification | GW8000-ES-C10 |
|---|---|
| Nominal AC output power | 8.0kW |
| Nominal apparent output power | 8.0kVA |
| Maximum AC active power | 8.8kW |
| Maximum apparent output to grid | 8.8kVA |
| Maximum apparent power from grid | 16.5kVA |
| Nominal grid voltage | 220 / 230 / 240V AC |
| Grid voltage range | 170ā280V AC |
| Nominal grid frequency | 50 / 60Hz |
| Maximum AC output current | 40A |
| Maximum AC input current from grid | 75A |
| Power factor | Approximately 1; adjustable 0.8 leading to 0.8 lagging |
| Maximum current THD | Less than 3% |
| Phase | Single phase |
Backup Output
| Specification | GW8000-ES-C10 |
|---|---|
| Nominal backup apparent power | 8.0kVA |
| Maximum backup power without grid | 8.8kVA continuous; 16.0kVA for 10 seconds |
| Maximum backup power with grid | 16.5kVA |
| Maximum backup current without grid | 40A |
| Maximum backup current with grid | 75A |
| Nominal backup voltage | 220 / 230 / 240V AC |
| Nominal backup frequency | 50 / 60Hz |
| Backup output THDv at linear load | Less than 3% |
| Backup switching time | Less than 4ms |
Generator Input
| Specification | GW8000-ES-C10 |
|---|---|
| Nominal generator apparent power | 8.0kVA |
| Maximum generator apparent power | 8.8kVA |
| Nominal generator input voltage | 220 / 230 / 240V AC |
| Generator input voltage range | 170ā280V AC |
| Nominal generator frequency | 50 / 60Hz |
| Maximum AC current from generator | 50A |
Efficiency, Construction and Connectivity
| Specification | GW8000-ES-C10 |
|---|---|
| Maximum efficiency | 97.6% |
| European efficiency | 96.2% |
| Maximum battery-to-AC efficiency | 95.5% |
| MPPT efficiency | 99.9% |
| Enclosure protection | IP66 |
| Operating temperature | -35°C to +60°C |
| Relative humidity | 0ā95% |
| Maximum operating altitude | 3,000m |
| Cooling method | Smart fan cooling |
| Dimensions (W Ć H Ć D) | 560 Ć 444.5 Ć 226mm |
| Weight | 27kg |
| Mounting | Wall mounted |
| Display and local interface | LCD, WLAN + app |
| Communications | RS485, WiFi, LAN and Bluetooth |
| Communication protocols | Modbus RTU and Modbus TCP |
| Topology | Non-isolated |
| AFCI | Optional |
| Rapid shutdown | Optional |
| Remote shutdown | Integrated |
Integrated Protection Functions
- PV string current monitoring
- PV insulation resistance detection
- Residual current monitoring
- PV reverse-polarity protection
- Anti-islanding protection
- AC overcurrent protection
- AC short-circuit protection
- AC overvoltage protection
- Integrated DC switch
- Type III DC surge protection
- Type III AC surge protection
Box Contents
Exact distributor package contents are Not Verified. The inverter, mounting plate, communication module, meter/CT, cables, documentation and accessories can vary by market or seller bundle. Confirm all supplied items before publishing or dispatch.
Installation and Compatibility Notes
- Installation must be performed by a qualified solar/electrical professional.
- Confirm the selected battery model on the current GoodWe compatibility list.
- Verify battery BMS communication, voltage, current and capacity requirements.
- Observe the unequal 32A/16A MPPT current limits and 2/1 string arrangement.
- Verify PV open-circuit voltage at the site's minimum expected temperature.
- Confirm local grid-code settings, utility approval and required protection equipment.
- Confirm cable sizing, breakers, isolators, surge protection and earthing.
- Connect backup output only to a correctly designed essential-load circuit.
- Generator compatibility, neutral arrangement and control settings require installer verification.
Warranty
Local warranty period and terms are Not Verified for this seller listing. Coverage may depend on country, distributor, registration, commissioning and installation conditions. Obtain written local warranty terms before purchase.
Technical Specifications
Specifications can vary by model or selected variant. Confirm final details before ordering.
Reliable Product Protection
Warranty availability can depend on the product, manufacturer and purchase conditions. Keep your invoice and product documentation.
Original products supplied through trusted distribution channels.
Our team can guide you regarding available product support.
Products are prepared carefully for safer transportation.
Professional Installation Guide
Inspect the Site
Confirm compatibility, location requirements and installation conditions.
Secure Installation
Mount the product securely according to manufacturer guidance.
Complete Connections
Connect the required solar, battery and electrical wiring safely.
Test the System
Verify configuration, protection and system performance before use.
Electrical and solar equipment should be installed by a qualified technician according to manufacturer instructions and local safety requirements.
Recommended Applications
Add the Applications metafield for product-specific use cases.
What You Receive
Add the Package Includes metafield for product-specific box contents.