{"product_id":"goodwe-gw6000-es-c10-6kw-hybrid-inverter","title":"GoodWe ES Uniq GW6000-ES-C10 6kW Single-Phase Hybrid Solar Inverter","description":"\u003cp\u003eThe GoodWe ES Uniq GW6000-ES-C10 is a 6kW single-phase low-voltage hybrid solar inverter designed for residential on-grid, battery-backup and off-grid applications. It supports up to 12kW PV input, 48V lithium-ion or lead-acid batteries, 140A continuous charging\/discharging, two MPPT trackers, IP66 protection and backup switching in less than 4ms.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6kW nominal single-phase AC output\u003c\/li\u003e\n\u003cli\u003eUp to 12kW recommended PV input power\u003c\/li\u003e\n\u003cli\u003e200% PV oversizing capability\u003c\/li\u003e\n\u003cli\u003eTwo independent MPPT trackers\u003c\/li\u003e\n\u003cli\u003e600V maximum PV input voltage\u003c\/li\u003e\n\u003cli\u003e48V nominal low-voltage battery system\u003c\/li\u003e\n\u003cli\u003eSupports lithium-ion and lead-acid batteries\u003c\/li\u003e\n\u003cli\u003e140A maximum continuous battery charge\/discharge current\u003c\/li\u003e\n\u003cli\u003e6kW maximum battery charging power\u003c\/li\u003e\n\u003cli\u003e6.6kW maximum battery discharging power\u003c\/li\u003e\n\u003cli\u003e6kVA nominal backup output\u003c\/li\u003e\n\u003cli\u003eUp to 12kVA backup surge power for 10 seconds\u003c\/li\u003e\n\u003cli\u003eSeamless backup switching in less than 4ms\u003c\/li\u003e\n\u003cli\u003eParallel operation of up to 6 inverters\u003c\/li\u003e\n\u003cli\u003eOn-grid and off-grid parallel support\u003c\/li\u003e\n\u003cli\u003eGenerator, smart-load and on-grid-inverter integration through multifunction port\u003c\/li\u003e\n\u003cli\u003eMicro-grid operation support\u003c\/li\u003e\n\u003cli\u003eMaximum efficiency up to 97.6%\u003c\/li\u003e\n\u003cli\u003eLCD interface plus WLAN\/app monitoring\u003c\/li\u003e\n\u003cli\u003eIP66 ingress protection\u003c\/li\u003e\n\u003cli\u003eOptional AI-driven AFCI, configuration-dependent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eBattery Input\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW6000-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eLithium-ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal battery voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd\u003e40–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery start-up voltage\u003c\/td\u003e\n\u003ctd\u003e44.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of battery inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charge current\u003c\/td\u003e\n\u003ctd\u003e140A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous discharge current\u003c\/td\u003e\n\u003ctd\u003e140A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum charging power\u003c\/td\u003e\n\u003ctd\u003e6.0kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum discharging power\u003c\/td\u003e\n\u003ctd\u003e6.6kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS communication\u003c\/td\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePV Input\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW6000-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum recommended PV input power\u003c\/td\u003e\n\u003ctd\u003e12,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV input voltage\u003c\/td\u003e\n\u003ctd\u003e600V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT operating voltage range\u003c\/td\u003e\n\u003ctd\u003e60–550V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up voltage\u003c\/td\u003e\n\u003ctd\u003e58V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV input voltage\u003c\/td\u003e\n\u003ctd\u003e360V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT trackers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV strings per MPPT\u003c\/td\u003e\n\u003ctd\u003e1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current per MPPT\u003c\/td\u003e\n\u003ctd\u003e20A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum short-circuit current per MPPT\u003c\/td\u003e\n\u003ctd\u003e26A \/ 26A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGrid Output \/ Input\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW6000-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC output power\u003c\/td\u003e\n\u003ctd\u003e6,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC active power\u003c\/td\u003e\n\u003ctd\u003e6,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum apparent power to grid\u003c\/td\u003e\n\u003ctd\u003e6,600VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e220 \/ 230 \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal grid frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC output current\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC input current from grid\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBackup Output\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW6000-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal backup apparent power\u003c\/td\u003e\n\u003ctd\u003e6.0kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum backup power without grid\u003c\/td\u003e\n\u003ctd\u003e6.6kVA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak backup power without grid\u003c\/td\u003e\n\u003ctd\u003e12.0kVA for 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum backup power with grid\u003c\/td\u003e\n\u003ctd\u003e8.8kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum backup current without grid\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum backup current with grid\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup switching time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eEfficiency, Construction \u0026amp; Communications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW6000-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean efficiency\u003c\/td\u003e\n\u003ctd\u003e96.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum battery-to-AC efficiency\u003c\/td\u003e\n\u003ctd\u003e95.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT efficiency\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-35°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eNatural convection \/ smart fan cooling, operating-condition dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e560 × 415 × 204mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 15.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eLCD, WLAN + app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eRS485, Wi-Fi, LAN, Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU \/ Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel operation\u003c\/td\u003e\n\u003ctd\u003eUp to 6 inverter units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFCI\u003c\/td\u003e\n\u003ctd\u003eOptional \/ configuration-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid shutdown\u003c\/td\u003e\n\u003ctd\u003eOptional \/ configuration-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eLong Product Description\u003c\/h2\u003e\n\u003cp\u003eThe GoodWe ES Uniq GW6000-ES-C10 is a 6kW single-phase hybrid inverter engineered for residential solar self-consumption, battery storage and reliable backup power. Its low-voltage 40–60V battery interface works with compatible 48V lithium-ion and lead-acid battery systems, while the 140A continuous charge\/discharge capability supports fast energy transfer.\u003c\/p\u003e\n\u003cp\u003eThe inverter accepts up to 12kW of PV input, allowing 200% PV oversizing relative to its 6kW nominal AC output. Two independent MPPT trackers, a 60–550V MPPT range and 20A input current per MPPT provide flexible rooftop-array design for modern high-current solar modules.\u003c\/p\u003e\n\u003cp\u003eFor backup applications, the inverter supplies 6kVA nominal backup power, up to 6.6kVA continuously without grid power and up to 12kVA for 10 seconds. Switching to backup occurs in less than 4ms, helping keep supported household loads operating during grid outages.\u003c\/p\u003e\n\u003cp\u003eThe ES Uniq platform supports on-grid and off-grid parallel operation of up to six inverters, micro-grid operation and flexible generator\/smart-load integration. An IP66 enclosure, LCD interface and app connectivity through Wi-Fi\/LAN\/Bluetooth support indoor or suitable outdoor wall-mounted installations and convenient system monitoring.\u003c\/p\u003e\n\u003ch2\u003eBattery Compatibility Note\u003c\/h2\u003e\n\u003cp\u003eThe inverter uses a 48V nominal, 40–60V battery platform and CAN BMS communication. Do not assume compatibility based only on voltage. Before purchase or installation, confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBattery model appears on the current GoodWe compatibility list\u003c\/li\u003e\n\u003cli\u003eBattery firmware and inverter firmware are supported\u003c\/li\u003e\n\u003cli\u003eCorrect CAN communication cable and pinout are used\u003c\/li\u003e\n\u003cli\u003eBattery current limits match the system design\u003c\/li\u003e\n\u003cli\u003eLead-acid charging parameters are configured by a qualified installer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOperating Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential solar self-consumption\u003c\/li\u003e\n\u003cli\u003eGrid-connected solar with battery storage\u003c\/li\u003e\n\u003cli\u003eWhole-home or selected-load backup\u003c\/li\u003e\n\u003cli\u003eOff-grid residential systems\u003c\/li\u003e\n\u003cli\u003eGenerator-assisted hybrid systems\u003c\/li\u003e\n\u003cli\u003eSmart-load control\u003c\/li\u003e\n\u003cli\u003eExpandable parallel inverter installations\u003c\/li\u003e\n\u003cli\u003eMicro-grid operation with supported PV inverters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × GoodWe GW6000-ES-C10 hybrid inverter\u003c\/li\u003e\n\u003cli\u003eWall-mounting bracket and standard mounting hardware, as supplied\u003c\/li\u003e\n\u003cli\u003eCommunication\/monitoring accessory supplied with the selected package\u003c\/li\u003e\n\u003cli\u003eConnection accessories supplied by the distributor\u003c\/li\u003e\n\u003cli\u003eUser documentation \/ quick installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003eExact meter, CT, communication module, connectors and accessories may vary by market or package. Confirm the box contents before publishing.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003eInstallation \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation and commissioning must be completed by a qualified solar\/electrical technician.\u003c\/li\u003e\n\u003cli\u003eConfirm PV string voltage and current remain within the inverter limits under all expected weather conditions.\u003c\/li\u003e\n\u003cli\u003eUse correctly rated DC and AC protection, cables, earthing and isolation equipment.\u003c\/li\u003e\n\u003cli\u003eFollow the current GoodWe installation manual, grid-code settings and battery compatibility list.\u003c\/li\u003e\n\u003cli\u003eOptional AFCI and rapid-shutdown functions depend on the ordered configuration and accessories.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GoodWe","offers":[{"title":"Default Title","offer_id":53121695416600,"sku":null,"price":198000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/75f2f485-8e82-4fbc-b074-b9eef7aa1baf.png?v=1793607781","url":"https:\/\/exsolar.pk\/products\/goodwe-gw6000-es-c10-6kw-hybrid-inverter","provider":"EXSOLAR.PK","version":"1.0","type":"link"}