{"product_id":"goodwe-gw10k-es-c10-10kw-hybrid-inverter","title":"GoodWe ES Uniq GW10K-ES-C10 10kW Single-Phase Hybrid Solar Inverter","description":"\u003cp\u003eThe GoodWe ES Uniq GW10K-ES-C10 is a 10kW single-phase low-voltage hybrid inverter designed for residential solar and energy-storage systems. It supports up to 20kW PV input, 48V lithium-ion or lead-acid batteries, 200A continuous charging\/discharging, dual MPPTs, IP66 protection and seamless backup switching in less than 4ms.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10kW nominal single-phase AC output\u003c\/li\u003e\n\u003cli\u003eUp to 20kW maximum PV input\u003c\/li\u003e\n\u003cli\u003e200% PV oversizing capability\u003c\/li\u003e\n\u003cli\u003eTwo independent MPPT trackers with two strings per MPPT\u003c\/li\u003e\n\u003cli\u003e600V maximum PV input voltage\u003c\/li\u003e\n\u003cli\u003e48V nominal low-voltage battery system\u003c\/li\u003e\n\u003cli\u003eCompatible with supported lithium-ion and lead-acid batteries\u003c\/li\u003e\n\u003cli\u003e200A maximum continuous battery charge\/discharge current\u003c\/li\u003e\n\u003cli\u003e10kW maximum battery charging power\u003c\/li\u003e\n\u003cli\u003e11kW maximum battery discharging power\u003c\/li\u003e\n\u003cli\u003e10kVA nominal backup output\u003c\/li\u003e\n\u003cli\u003eUp to 20kVA backup surge output for 10 seconds\u003c\/li\u003e\n\u003cli\u003eBackup switching in less than 4ms\u003c\/li\u003e\n\u003cli\u003eParallel operation of up to 6 inverters\u003c\/li\u003e\n\u003cli\u003eGenerator, smart-load and on-grid-inverter integration through a 3-in-1 port\u003c\/li\u003e\n\u003cli\u003eMicro-grid operation support\u003c\/li\u003e\n\u003cli\u003eMaximum efficiency up to 97.6%\u003c\/li\u003e\n\u003cli\u003eLCD plus WLAN\/app monitoring\u003c\/li\u003e\n\u003cli\u003eWi-Fi, LAN and Bluetooth communication support\u003c\/li\u003e\n\u003cli\u003eIP66 ingress protection\u003c\/li\u003e\n\u003cli\u003eOptional AI-driven AFCI and rapid shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eBattery Input\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW10K-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eLithium-ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal battery voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd\u003e40–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery start-up voltage\u003c\/td\u003e\n\u003ctd\u003e44.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of battery inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charge current\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous discharge current\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum charging power\u003c\/td\u003e\n\u003ctd\u003e10.0kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum discharging power\u003c\/td\u003e\n\u003ctd\u003e11.0kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS communication\u003c\/td\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePV Input\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW10K-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV input power\u003c\/td\u003e\n\u003ctd\u003e20,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV input voltage\u003c\/td\u003e\n\u003ctd\u003e600V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT operating voltage range\u003c\/td\u003e\n\u003ctd\u003e60–550V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT range at nominal power\u003c\/td\u003e\n\u003ctd\u003e170–500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up voltage\u003c\/td\u003e\n\u003ctd\u003e58V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV input voltage\u003c\/td\u003e\n\u003ctd\u003e360V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT trackers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV strings per MPPT\u003c\/td\u003e\n\u003ctd\u003e2 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current per MPPT\u003c\/td\u003e\n\u003ctd\u003e32A \/ 32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current per string\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum short-circuit current per MPPT\u003c\/td\u003e\n\u003ctd\u003e48A \/ 48A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAC Output — On-Grid\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW10K-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC output power\u003c\/td\u003e\n\u003ctd\u003e10.0kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal apparent power\u003c\/td\u003e\n\u003ctd\u003e10.0kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC active power\u003c\/td\u003e\n\u003ctd\u003e11.0kW, subject to regional grid requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum apparent power to grid\u003c\/td\u003e\n\u003ctd\u003e11.0kVA, subject to regional grid requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum apparent power from grid\u003c\/td\u003e\n\u003ctd\u003e16.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e220V \/ 230V \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage range\u003c\/td\u003e\n\u003ctd\u003e170–280V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal grid frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid frequency range\u003c\/td\u003e\n\u003ctd\u003e45–55Hz \/ 55–65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC output current\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC current from grid\u003c\/td\u003e\n\u003ctd\u003e75A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor\u003c\/td\u003e\n\u003ctd\u003eApproximately 1; adjustable 0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd\u003eBelow 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAC Output — Backup\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW10K-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal backup apparent power\u003c\/td\u003e\n\u003ctd\u003e10.0kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum backup power without grid\u003c\/td\u003e\n\u003ctd\u003e11.0kVA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup surge power\u003c\/td\u003e\n\u003ctd\u003e20.0kVA for 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum backup power with grid\u003c\/td\u003e\n\u003ctd\u003e16.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output current without grid\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output current with grid\u003c\/td\u003e\n\u003ctd\u003e75A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e220V \/ 230V \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput THDv at linear load\u003c\/td\u003e\n\u003ctd\u003eBelow 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup transfer time\u003c\/td\u003e\n\u003ctd\u003eLess than 4ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGenerator Input\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eGW10K-ES-C10\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal generator apparent power\u003c\/td\u003e\n\u003ctd\u003e10.0kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum generator apparent power\u003c\/td\u003e\n\u003ctd\u003e11.0kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal generator voltage\u003c\/td\u003e\n\u003ctd\u003e220V \/ 230V \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator input voltage range\u003c\/td\u003e\n\u003ctd\u003e170–280V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum generator input current\u003c\/td\u003e\n\u003ctd\u003e54.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean efficiency\u003c\/td\u003e\n\u003ctd\u003e96.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum battery-to-AC efficiency\u003c\/td\u003e\n\u003ctd\u003e95.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT efficiency\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConstruction and Operating Data\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e560 × 444.5 × 226mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e29.0kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSmart fan cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-35°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eLCD, WLAN and app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS communication\u003c\/td\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, Wi-Fi, LAN and Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication protocols\u003c\/td\u003e\n\u003ctd\u003eModbus-RTU and Modbus-TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eIntegrated Protection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePV string current monitoring\u003c\/li\u003e\n\u003cli\u003ePV insulation-resistance detection\u003c\/li\u003e\n\u003cli\u003eResidual-current monitoring\u003c\/li\u003e\n\u003cli\u003ePV reverse-polarity protection\u003c\/li\u003e\n\u003cli\u003eAnti-islanding protection\u003c\/li\u003e\n\u003cli\u003eAC overcurrent protection\u003c\/li\u003e\n\u003cli\u003eAC short-circuit protection\u003c\/li\u003e\n\u003cli\u003eAC overvoltage protection\u003c\/li\u003e\n\u003cli\u003eIntegrated DC switch\u003c\/li\u003e\n\u003cli\u003eType III DC surge protection\u003c\/li\u003e\n\u003cli\u003eType III AC surge protection\u003c\/li\u003e\n\u003cli\u003eIntegrated remote shutdown\u003c\/li\u003e\n\u003cli\u003eOptional AFCI\u003c\/li\u003e\n\u003cli\u003eOptional rapid shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetailed Product Description\u003c\/h2\u003e\n\u003cp\u003eThe GoodWe ES Uniq GW10K-ES-C10 combines solar generation, low-voltage battery storage, grid power, backup loads and generator integration in one residential energy platform. Its 10kW nominal single-phase output is suitable for larger homes and other compatible installations where reliable backup and high PV utilization are required.\u003c\/p\u003e\n\u003cp\u003eThe inverter accepts up to 20kW of PV input, providing 200% PV oversizing relative to its nominal AC rating. Two MPPT trackers and four total string inputs help system designers divide arrays across different roof orientations or operating conditions while staying within the published voltage and current limits.\u003c\/p\u003e\n\u003cp\u003eOn the battery side, the GW10K-ES-C10 operates with a 48V nominal battery system and supports up to 200A continuous charging and discharging. It provides up to 10kW charging power and 11kW discharging power when operating conditions and the selected compatible battery allow.\u003c\/p\u003e\n\u003cp\u003eDuring an outage, the inverter can switch to backup in less than 4ms. Its backup output is rated at 10kVA nominal, can supply up to 11kVA continuously without the grid and can deliver up to 20kVA for 10 seconds to assist with short startup surges. Actual load performance depends on battery capability, temperature, configuration and system design.\u003c\/p\u003e\n\u003cp\u003eThe ES Uniq platform also supports generator input, smart-load control, micro-grid operation and parallel expansion of up to six compatible units. IP66 protection, integrated electrical safeguards and remote monitoring make it suitable for professionally designed indoor or outdoor residential installations.\u003c\/p\u003e\n\u003ch2\u003eBattery Compatibility\u003c\/h2\u003e\n\u003cp\u003eUse only batteries listed in the latest GoodWe compatibility documentation or batteries approved by GoodWe for the applicable market and firmware. The inverter supports compatible lithium-ion and lead-acid batteries within its published 40–60V operating range.\u003c\/p\u003e\n\u003cp\u003eGoodWe's current solution documentation includes compatible configurations using selected Lynx A, Lynx U and GoodWe low-voltage battery models. Battery quantity, maximum parallel clusters, BMS protocol and cable requirements vary by model.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAlways confirm the exact battery model, BMS compatibility, firmware and recommended configuration before sale or installation.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × GoodWe GW10K-ES-C10 hybrid inverter\u003c\/li\u003e\n\u003cli\u003eWall-mounting bracket and standard mounting hardware, as supplied\u003c\/li\u003e\n\u003cli\u003eCommunication\/monitoring accessory supplied with the selected package\u003c\/li\u003e\n\u003cli\u003eConnection accessories supplied by the distributor\u003c\/li\u003e\n\u003cli\u003eUser documentation \/ quick installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003eExact smart meter, CT, Wi-Fi\/LAN module, connectors and accessories may vary by market and distributor. Confirm box contents before publishing.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003eInstallation and Safety Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation and commissioning must be completed by a qualified solar\/electrical technician.\u003c\/li\u003e\n\u003cli\u003eConfirm PV string voltage and current remain within all inverter limits under expected weather conditions.\u003c\/li\u003e\n\u003cli\u003eUse correctly rated PV, battery, AC, generator and backup protection, cabling, earthing and isolation equipment.\u003c\/li\u003e\n\u003cli\u003eFollow the latest GoodWe manual, approved battery list and local grid-code requirements.\u003c\/li\u003e\n\u003cli\u003eOptional AFCI, rapid shutdown and communication functions depend on the ordered configuration and accessories.\u003c\/li\u003e\n\u003cli\u003eOutput limits and grid settings may vary by country or applicable grid code.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GoodWe","offers":[{"title":"Default Title","offer_id":53122034073880,"sku":null,"price":373000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/81063b33-bc0f-413b-8141-e6aab06e3bfe.png?v=1793610949","url":"https:\/\/exsolar.pk\/products\/goodwe-gw10k-es-c10-10kw-hybrid-inverter","provider":"EXSOLAR.PK","version":"1.0","type":"link"}