{"title":"Solar Accessories","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eComplete your solar installation with premium \u003cstrong\u003eSolar Accessories\u003c\/strong\u003e from ExSolar.pk. Explore a wide range of genuine solar components including MC4 connectors, DC \u0026amp; AC cables, cable lugs, cable glands, combiner boxes, junction boxes, mounting clamps, aluminum rails, earthing materials, cable ties, insulation tapes, bolts, nuts, and other essential installation accessories. Our products are sourced from trusted manufacturers to ensure maximum safety, durability, and long-term performance for residential, commercial, and industrial solar systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"cnc-2-pole-32a-dc-breaker","title":"CNC YCB8-63PV 2-Pole 32A 500V DC Solar MCB Breaker","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Identification\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eField\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eVerified Result\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCNC Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB8-63PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e2P, 32A, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eDC Protection Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSolar Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eYCB8-63PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003ePolarity-sensitive\/heteropolarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eProduct Title\u003c\/h2\u003e\n\u003cp class=\"\"\u003eCNC YCB8-63PV 2-Pole 32A 500V DC Solar MCB Breaker\u003c\/p\u003e\n\u003ch2\u003eShort Description\u003c\/h2\u003e\n\u003cp\u003eThe CNC YCB8-63PV is a two-pole, 32A photovoltaic DC miniature circuit breaker rated for 500VDC. It provides overload, short-circuit and isolation protection with 6kA breaking capacity, thermomagnetic tripping and DIN-rail installation.\u003c\/p\u003e\n\u003ch2\u003eLong Description\u003c\/h2\u003e\n\u003cp\u003eProtect compatible photovoltaic and DC circuits with the CNC YCB8-63PV 2P 32A miniature circuit breaker. Its two-pole configuration is rated for 500VDC and combines overload, short-circuit and isolation functions.\u003c\/p\u003e\n\u003cp\u003eThe pictured breaker carries a K-characteristic\/10×In marking and features a linked two-pole handle, green status windows, polarity markings and standard DIN35 mounting. Installation must follow the official wiring diagram, marked polarity, conductor requirements and applicable electrical regulations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExact 2-pole, 32A configuration\u003c\/li\u003e\n\u003cli\u003e500VDC rated working voltage\u003c\/li\u003e\n\u003cli\u003e6kA ultimate breaking capacity\u003c\/li\u003e\n\u003cli\u003eIcs equal to 100% of Icu\u003c\/li\u003e\n\u003cli\u003eThermomagnetic operation\u003c\/li\u003e\n\u003cli\u003eK characteristic\/10×In product marking\u003c\/li\u003e\n\u003cli\u003eOverload protection\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli\u003eDC circuit isolation\u003c\/li\u003e\n\u003cli\u003e1200VDC insulation voltage\u003c\/li\u003e\n\u003cli\u003e4kV impulse withstand voltage\u003c\/li\u003e\n\u003cli\u003eDIN35 rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOfficial Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Working Voltage\u003c\/td\u003e\n\u003ctd\u003e500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Type\u003c\/td\u003e\n\u003ctd\u003eThermomagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePictured Trip Characteristic\u003c\/td\u003e\n\u003ctd\u003eK, Ii = 10×In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Curve Options\u003c\/td\u003e\n\u003ctd\u003eB, C and K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage Ui\u003c\/td\u003e\n\u003ctd\u003e1200VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Voltage Uimp\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Breaking Capacity Icu\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Breaking Capacity Ics\u003c\/td\u003e\n\u003ctd\u003e100% of Icu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e1,500 operations in technical documentation*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN35\/TH35-7.5 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5–25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed Conductor for 32A\u003c\/td\u003e\n\u003ctd\u003e6mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Torque\u003c\/td\u003e\n\u003ctd\u003e3.5N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 2,000m; derating above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eII\/III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.6 × 78.8 × 85.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot Verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eNot Verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e*An official marketing statement mentions 10,000 electrical operations, while the technical table and manual specify 1,500. Confirm the documentation revision supplied with the unit.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolar PV protection boards\u003c\/li\u003e\n\u003cli\u003ePV combiner and distribution boxes\u003c\/li\u003e\n\u003cli\u003eInverter-side DC protection\u003c\/li\u003e\n\u003cli\u003eResidential and commercial solar systems\u003c\/li\u003e\n\u003cli\u003eIndustrial DC distribution\u003c\/li\u003e\n\u003cli\u003eCommunication DC systems\u003c\/li\u003e\n\u003cli\u003eDC circuit isolation within verified ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBox Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCNC YCB8-63PV 2P 32A breaker ×1\u003c\/li\u003e\n\u003cli\u003ePrinted instructions\/accessories: Not Verified\u003c\/li\u003e\n\u003cli\u003eRetail packaging contents: Not Verified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProtection Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOverload protection\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli\u003eDC isolation\u003c\/li\u003e\n\u003cli\u003eThermomagnetic tripping\u003c\/li\u003e\n\u003cli\u003eLinked two-pole switching\u003c\/li\u003e\n\u003cli\u003e6kA fault-current interruption\u003c\/li\u003e\n\u003cli\u003eStatus indication windows\u003c\/li\u003e\n\u003cli\u003ePolarity markings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications and Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIEC\/EN 60947-2\u003c\/li\u003e\n\u003cli\u003eEU RoHS environmental requirements\u003c\/li\u003e\n\u003cli\u003eCE marking visible on the product; exact certificate URL Not Verified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified using the \u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.cncele.com\/dc-mcb-for-solar-ycb8-63pv-product\/?utm_source=chatgpt.com\"\u003eofficial CNC product page\u003c\/a\u003e, \u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.cncele.com\/uploads\/DC-MCB-Solar-Miniature-Circuit-Breaker-polarity-YCB8-63PV-Catalogue-23.12.3.pdf?utm_source=chatgpt.com\"\u003eofficial catalogue\u003c\/a\u003e and \u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.cncele.com\/uploads\/DC-MCB-Solar-Miniature-Circuit-Breaker-polarity-YCB8-63PV-Instructions-23.9.8.pdf?utm_source=chatgpt.com\"\u003eofficial operation manual\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNot Verified.\u003c\/strong\u003e The reviewed official documents do not state a commercial warranty period for the exact 2P 32A configuration.\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52479735726360,"sku":null,"price":1750.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/ChatGPTImageAug5_2026_02_13_27PM_1.png?v=1785921224"},{"product_id":"sunwoda-5kw-51-v-100ah-lithium-battery","title":"Sunwoda Energy Atrix-SE 5kWh 51.2V 100Ah Lithium Battery Module","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified product data\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSunwoda Energy Lithium Battery Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact model on supplied label\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB051100P02-SE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem model on supplied label\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix-SE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSunwoda Energy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLocal co-brand shown on carton\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLuminey\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-voltage lithium battery \/ residential energy storage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51.2V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLabel-derived nominal energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.12kWh (51.2V × 100Ah)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePublic Sunwoda family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix \/ Atrix-5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eSunwoda Energy Atrix-SE 5kWh 51.2V 100Ah Lithium Battery Module\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied battery is identified by its carton label as Sunwoda Energy model B051100P02-SE, system Atrix-SE, rated 51.2V and 100Ah. It is a low-voltage lithium battery module for solar energy-storage and backup applications. Sunwoda's current public Atrix-5 documentation lists a 5kWh-class LFP platform with CAN 2.0\/RS485 communication, 100% DOD capability, IP20 indoor protection and natural-convection cooling.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe Sunwoda Energy Atrix platform is designed for modular residential energy storage, allowing solar energy to be stored for self-consumption, peak-time use and backup applications. The supplied unit label confirms model B051100P02-SE, system Atrix-SE, with 51.2V nominal voltage and 100Ah capacity. Multiplying the nameplate voltage and capacity gives 5.12kWh of nominal electrical capacity; Sunwoda markets the corresponding Atrix-5 family as a 5kWh nominal\/usable-energy module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe current Sunwoda Atrix-5 platform uses lithium iron phosphate chemistry, CAN 2.0\/RS485 communication, indoor IP20 protection and natural-convection cooling. The official Atrix product page lists 100% depth of discharge under its stated test conditions and supports modular expansion with an optional Data Box.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause Sunwoda's public documents currently identify the base Atrix-5\/B051100P02 family rather than the exact B051100P02-SE suffix, family specifications are distinguished below from facts directly confirmed on the supplied product label.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact supplied model: B051100P02-SE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem model: Atrix-SE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e51.2V nominal voltage and 100Ah nameplate capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e5.12kWh calculated nominal electrical capacity from nameplate values\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSunwoda Atrix 5kWh-class residential energy-storage platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLFP chemistry on the officially documented Atrix\/B051100P02 platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAN 2.0 and RS485 communication on current Atrix-5 platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e100% DOD listed for current Atrix-5 under Sunwoda test conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 indoor enclosure rating on current Atrix-5 platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNatural-convection cooling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular rack\/cabinet installation concept\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated BMS-based monitoring and protection on the Atrix platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue \/ verification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB051100P02-SE — supplied carton label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix-SE — supplied carton label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1412021100271 — supplied carton label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51.2V — supplied carton label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100Ah — supplied carton label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalculated nominal energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.12kWh — derived from 51.2V × 100Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSunwoda marketed nominal energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5kWh — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUsable energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5kWh at 100% DOD — current official Atrix-5 documentation; exact -SE suffix not separately published\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery chemistry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium-ion on supplied carton; LFP on official Atrix\/B051100P02 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCell connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P16S — official B051100P02 manual; exact -SE suffix not separately published\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking \/ cut-off voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e44.8–55.2V — official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated charge \/ discharge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50A \/ 80A — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum charge \/ discharge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100A \/ 100A — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN 2.0 \/ RS485 — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOptional monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBattery APP \/ remote monitoring on Atrix family\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScalability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 240 modules in parallel with optional Data Box — current Atrix family documentation; exact Atrix-SE limit Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndoor — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure protection rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural convection — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDischarge temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−20°C to +50°C — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharge temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−10°C to +50°C — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–95%, non-condensing — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;4,000m — current official Atrix-5 documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e440 × 135 × 410mm per pack — current Atrix-5 documentation; exact B051100P02-SE dimensions Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45kg — current Atrix-5 documentation; exact B051100P02-SE weight Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCycle life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for exact B051100P02-SE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRound-trip efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for exact B051100P02-SE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent official Atrix-5 documentation states 10 years; applicability to exact Atrix-SE Pakistan variant Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar energy storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHome backup during grid outages\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar self-consumption optimization\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePeak shaving \/ time-of-use energy management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-voltage hybrid inverter battery systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRack or cabinet-based modular battery banks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential and light-commercial backup systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery module ×1 — confirmed by supplied carton label (\u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003eQuantity: 1PCS\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower \/ communication wiring set: Not Verified for this exact carton\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting hardware \/ rack components: Not Verified for this exact carton\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData Box \/ display: Not Verified; public Atrix documentation describes it as optional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual: Not Verified for this exact carton\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe official Atrix\/B051100P02 manual lists the following BMS protection functions for the base platform; the exact \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003e-SE\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e suffix is not separately documented publicly:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCharging over-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDischarging under-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-temperature protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery status monitoring through the BMS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eSunwoda's current Atrix-5 product documentation lists the following for the Atrix family:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62619\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCEI 0-21\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL 1973\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFCC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUN38.3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied shipping carton is also marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUN3480\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for lithium-ion battery transport. Certification documents explicitly naming the \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003eB051100P02-SE\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e suffix: Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eSunwoda's current official Atrix-5 page and 2025 Atrix datasheet state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e warranty for Atrix-5, subject to Sunwoda warranty terms. Whether that same term applies unchanged to the exact Luminey\/Atrix-SE B051100P02-SE unit sold in Pakistan is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and should be confirmed with the authorized local seller\/distributor.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunwooda","offers":[{"title":"Default Title","offer_id":52482798977304,"sku":null,"price":240000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-square_1.png?v=1786002394"},{"product_id":"lvtopsun-12v-100ah-lithium-battery","title":"LVTOPSUN 12V 100Ah LiFePO4 Lithium Battery – 1.2kWh Class","description":"\u003ch1\u003e\u003cspan\u003eLVTOPSUN 12V 100Ah LiFePO4 Battery — Shopify Product Data\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LVTOPSUN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Low-voltage LiFePO4 lithium battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSupplied-unit label:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12V 100Ah LiFePO4 Battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEnergy from supplied label:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e approximately 1.20kWh (12V × 100Ah; calculated, not a separate manufacturer rating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eClosest current official LVTOPSUN model:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LVTS-128100-E — 12.8V, 100Ah, 1.28kWh\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eExact model number of supplied unit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCategory:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Battery \/ Low Voltage Energy Storage \/ Backup Battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eVerification note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The supplied battery label states 12V, 100Ah, LiFePO4 and IP65. LVTOPSUN's current public LVTS-128100-E documentation states 12.8V, 100Ah, 1.28kWh and IP54. Because the supplied unit does not display a model number and its IP marking differs, the supplied unit is not represented here as definitively being LVTS-128100-E. Model-specific specifications below are clearly separated from label-verified data.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eLVTOPSUN 12V 100Ah LiFePO4 Lithium Battery – 1.2kWh Class\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCompact LVTOPSUN low-voltage LiFePO4 battery for solar storage, backup and off-grid applications. The supplied unit is labeled 12V 100Ah with IP65, CE and UN38.3 markings, giving approximately 1.20kWh of nominal energy by calculation. LVTOPSUN's closest current public model is the 12.8V 100Ah LVTS-128100-E, but exact model correspondence is not verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe LVTOPSUN 12V 100Ah LiFePO4 battery is a compact low-voltage energy-storage solution suited to small solar, backup and off-grid installations. The supplied product label confirms a 12V, 100Ah LiFePO4 configuration and carries IP65, CE and UN38.3 markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor manufacturer reference, LVTOPSUN currently publishes the LVTS-128100-E in its low-voltage ESS range. That official model is rated at 12.8V, 100Ah and 1.28kWh and is designed for residential backup, small photovoltaic systems, telecom power supplies and other off-grid applications. LVTOPSUN also specifies LiFePO4 chemistry, cobalt-free cells and series\/parallel expansion for that model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the supplied battery's label does not show a model number and its IP65 marking differs from the IP54 rating published for LVTS-128100-E, ExSolar.pk should not present model-specific LVTS-128100-E specifications as guaranteed for this exact unit unless the manufacturer or supplier confirms the model identity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e12V nominal class shown on supplied battery label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e100Ah capacity shown on supplied battery label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApproximately 1.20kWh nominal energy from 12V × 100Ah calculation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLithium Iron Phosphate (LiFePO4) chemistry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-voltage battery for energy-storage and backup applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP65 marking on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE marking on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUN38.3 marking on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRobust enclosed battery form factor with top terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClosest official LVTOPSUN 12.8V 100Ah product: LVTS-128100-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial LVTS-128100-E supports residential backup, small PV, telecom and off-grid use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial LVTS-128100-E is specified as cobalt-free LiFePO4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSupplied Unit \/ Verification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLVTOPSUN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiFePO4 \/ Lithium Iron Phosphate — verified from supplied label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLabel Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12V — verified from supplied label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100Ah — verified from supplied label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalculated Energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.20kWh (12V × 100Ah) — calculated from supplied label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Model Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eClosest Official Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLVTS-128100-E — closest public LVTOPSUN 100Ah\/12.8V product; exact mapping \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial-model Nominal Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.8V, 100Ah, 1.28kWh — applies to LVTS-128100-E only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBulk Charge Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e14V — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFloat Charge Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e13.8V — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCutoff Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e11.6V — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharge Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e50A — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDischarge Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e100A — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-Circuit Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eApprox. 1000A — LVTS-128100-E datasheet value; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W×D×H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e260 × 168 × 210mm — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e9.85kg — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e-20°C to 60°C — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e≤95% RH — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Operating Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e≤2000m — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIP65 on supplied label; official LVTS-128100-E datasheet states IP54 — exact model correspondence \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCycle Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e6000 cycles @ 80% DOD \/ 25°C \/ 0.5C, 60% EOL — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScalability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eMax 4 in series and max 4 in parallel — LVTS-128100-E only; supplied unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e5 years in LVTS-128100-E datasheet; warranty for supplied unit\/Pakistan \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential backup power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall-scale photovoltaic \/ solar storage systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff-grid energy systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTelecom power supplies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall office and shop backup systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-voltage renewable-energy storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe first four applications are specifically described by LVTOPSUN for the LVTS-128100-E product class; suitability of any load or inverter must be checked against the exact battery\/inverter requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery module: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified as packaged box content\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (product is shown in supplied photos)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser manual: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting\/installation accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarranty card: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOvercharge prevention — described by LVTOPSUN for LVTS-128100-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDeep-discharge prevention — described by LVTOPSUN for LVTS-128100-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-current protection — \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified for supplied unit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection — \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified for supplied unit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-temperature protection — \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified for supplied unit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery-management-system details for supplied unit — \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications \/ Markings\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE — shown on supplied label and listed for LVTS-128100-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUN38.3 — shown on supplied label and listed for LVTS-128100-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMSDS — marking shown on supplied label; supporting document \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP65 — ingress-protection marking shown on supplied unit; conflicts with the IP54 rating of the current LVTS-128100-E datasheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe official LVTS-128100-E product parameter sheet states a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5-year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for that model. Warranty coverage for the supplied 12V\/IP65 unit and Pakistan market is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"LV TopSun","offers":[{"title":"Default Title","offer_id":52482822144280,"sku":null,"price":55000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-square_2.png?v=1786004018"},{"product_id":"tomzn-ac-breaker-32a-2-pole","title":"TOMZN TOB1L-63H C32 32A 2-Pole 30mA AC RCBO","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1L-63H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32, 32A, 2P, 30mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC circuit protection \/ RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResidual Current Circuit Breaker with Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent system\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-phase 230V AC, L+N disconnection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolar classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC-side protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNot suitable as\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC\/PV string breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant: the attached product is an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRCBO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not an ordinary MCB. It combines residual-current (earth-leakage), overload and short-circuit protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB1L-63H C32 is a 32A, 2-pole AC RCBO designed to disconnect both line and neutral while providing 30mA earth-leakage, overload and short-circuit protection. The supplied unit is marked for 230V AC, 50\/60Hz operation, a 6kA breaking capacity and IEC 61009-1 compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eProtect residential AC circuits with one compact device. The TOMZN TOB1L-63H C32 combines overcurrent and residual-current protection, helping guard wiring against overloads and short circuits while responding to sinusoidal alternating earth-fault currents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis 32A variant is rated for 230V AC at 50\/60Hz and disconnects both L and N. Its 30mA residual-current sensitivity, yellow test button, linked blue operating toggle and visible status window make routine operation and functional testing straightforward. The product label identifies a 6kA breaking capacity, Type AC residual-current marking and IEC 61009-1 standard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe unit is intended for correctly designed residential distribution circuits. Selection, wiring and installation must be completed by a qualified electrician in accordance with local electrical regulations and the official wiring information for the product.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRCBO combining earth-leakage, overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A rated current with C tripping-curve marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole configuration that disconnects both line and neutral\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e30mA rated residual operating current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType AC residual-current marking for sinusoidal alternating earth-fault currents\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e230V AC rated voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz rated frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit breaking capacity marked on the unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual operating time marked as no more than 0.1 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eYellow test button with “test monthly” instruction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGreen mechanical\/status indication window\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61009-1 marking on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1L-63H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P; disconnects L and N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC (C32 marking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated residual operating current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-current type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType AC marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual operating time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated short-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000A \/ 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable product standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61009-1 marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLeakage-protection control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer states it can be manually enabled or disabled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine and neutral disconnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes; manufacturer states both L and N are cut off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest facility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYellow T test button; “test monthly” marked on unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreen indicator window\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFour screw terminals visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal conductor capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical\/electrical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial model-specific warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSingle-phase 230V AC branch-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCircuits requiring combined leakage and overcurrent protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional protection against direct contact and protection against indirect contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection against fire risk associated with insulation faults\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in a suitably engineered power or solar installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eFinal circuit suitability and breaker coordination must be confirmed by a qualified electrician. This is not a DC\/PV breaker.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × TOMZN TOB1L-63H C32 RCBO unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual, wiring sheet, packaging and any additional accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSinusoidal alternating earth-fault current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection against indirect contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional protection against direct contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection against fire hazards caused by insulation faults\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous L and N disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarking \/ certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61009-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on the supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE mark visible on the supplied product; model-specific certificate not located\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB \/ TÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e TOMZN states that warranty periods vary by product category, but no model-specific warranty term for the TOB1L-63H C32 was located on the official product page. Confirm the applicable ExSolar.pk or manufacturer warranty before publishing a duration.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52501767094552,"sku":null,"price":1650.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner.png?v=1786263299"},{"product_id":"mora-ac-breaker-32a-2-pole","title":"MORA AES C32 32A 2-Pole 400V AC 6kA MCB","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ model marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32, 32A, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC circuit protection \/ Miniature Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical system\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolar classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC-side protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNot suitable as\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRCBO\/RCCB or DC\/PV string breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThis product is an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMCB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not an RCBO. The supplied unit has no residual-current test button or 30mA leakage marking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES C32 is a 32A, two-pole AC miniature circuit breaker designed for overload and short-circuit protection. The supplied unit is marked for 400V AC, 50\/60Hz operation, 6kA breaking capacity and IEC 60898-1, with a linked orange operating handle and dual status windows.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES C32 provides compact two-pole overcurrent protection for appropriately designed AC distribution circuits. Its C32 marking identifies a C tripping curve and 32A rated current, while the linked operating handle switches both poles together.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied breaker is marked for 400V AC at 50\/60Hz, a 6000A short-circuit breaking capacity and IEC 60898-1. Two green status windows support quick visual inspection, while the orange linked handle provides clear manual ON\/OFF operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis MCB is intended for correctly engineered AC circuits requiring overload and short-circuit protection. It does not provide residual-current or earth-leakage protection. Product selection, protective coordination, wiring and installation must be completed by a qualified electrician in accordance with local electrical regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole AC miniature circuit breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A rated current identified by the C32 marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC tripping curve\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked operation of both poles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC rated voltage marked on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz rated frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6000A \/ 6kA short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60898-1 standard marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo green status windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-visibility orange linked operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ model marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated short-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000A \/ 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable product standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60898-1 marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating handle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOrange linked two-pole handle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo green indicator windows\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of visible terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-current \/ leakage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo such function verified; product is an MCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal conductor capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating-temperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical\/electrical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial model-specific warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection for suitably rated AC branch circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection for suitably rated AC branch circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole switching in compatible AC distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential or commercial AC distribution where the electrical design and local code permit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in a suitably engineered power or solar installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eCircuit compatibility, cable size, prospective fault current and protective coordination must be confirmed by a qualified electrician. This is not a DC\/PV breaker and does not replace an RCCB or RCBO where leakage protection is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × MORA AES C32 32A 2P MCB unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging, printed manual and additional accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous linked operation of two poles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included or not verified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e earth-leakage protection, residual-current protection, surge protection, over\/under-voltage protection and arc-fault protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarking \/ certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on the supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE mark visible on the supplied product; model-specific certificate not located\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB \/ TÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The official MORA Pakistan website mentions warranty and after-sales support but does not publish a model-specific warranty duration for this AES C32 breaker. Its published 7-day return policy is not presented as the product warranty. Confirm the applicable ExSolar.pk or manufacturer warranty before listing a duration.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52501775384856,"sku":null,"price":1599.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_1.png?v=1786265104"},{"product_id":"chint-ac-breaker-32a-2-pole","title":"CHINT NXB-63 C32 32A 2-Pole 400V AC 6kA MCB","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNXB-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32, 32A, 2P, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFinal power distribution \/ AC circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal-magnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolar classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC-side protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNot suitable as\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRCBO\/RCCB or DC\/PV string breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThis product is an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMCB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not an RCBO. It provides overload, short-circuit and isolation functions but does not provide residual-current or earth-leakage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NXB-63 C32 is a 32A, two-pole thermal-magnetic AC miniature circuit breaker for overload, short-circuit and positive-isolation protection. This variant is marked for 400V AC, 50Hz operation and 6kA breaking capacity, with a C tripping curve, linked blue handle and clear contact-status indicators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for dependable final power distribution, the CHINT NXB-63 C32 combines compact modular construction with precise thermal-magnetic protection. Its C32 rating is suited to compatible mixed and moderately inductive circuits where normal inrush current requires a C-curve response.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe two-pole mechanism switches both poles together and the front indicator windows provide a clear operating-state reference: CHINT identifies red as ON and green as OFF. This supplied variant carries 400V AC, 50Hz, 6000A, IEC 60898-1 and GB\/T 10963.1 markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCHINT’s official NXB-63 documentation specifies TH35-7.5 DIN-rail mounting, top or bottom cable entry, 2.0N·m terminal torque, a 500V insulation rating, 4kV impulse withstand voltage and long mechanical and electrical operating life. Installation and protective coordination must be completed by a qualified electrician in accordance with local regulations and the official manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A two-pole AC miniature circuit breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC tripping curve with 5–10 × In instantaneous operating range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal-magnetic overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePositive-isolation function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC rating marked on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6000A \/ 6kA short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked two-pole blue operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed\/green contact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTH35-7.5 DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTop or bottom cable entry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20,000-operation mechanical life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60898-1 compliant NXB-63 series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNXB-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal-magnetic Miniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-curve instantaneous range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage on supplied unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial 2P series voltage options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220\/230\/240V AC and 380\/400\/415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency on supplied unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated short-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000A \/ 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated service short-circuit capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated impulse withstand voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric test voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000V, power-frequency test for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTH35-7.5 \/ 35mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable entry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop or bottom\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–25mm² copper conductor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended copper conductor for 25–32A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–6mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire stripping length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating-temperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage-temperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−35°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum installation altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection degree, direct mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection degree, inside distribution box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePosition indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed = ON; Green = OFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, short circuit, positive isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional marking on supplied unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 10963.1; CCC mark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-pole modular width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComplete overall dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to official 2P drawing; not reproduced without the dimensional diagram\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial model-specific warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential final distribution circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial electrical distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight-industrial final power distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLighting and socket branch circuits where a C32 rating is correctly coordinated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible appliance and moderately inductive circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in a suitably engineered power or solar installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual circuit isolation during maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThe official manual states that the product is not suitable for directly starting high-inductive or high-capacity loads such as fans, motors, electric-heating equipment and capacitor cabinets. Circuit suitability, cable sizing and fault-level coordination must be confirmed by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × CHINT NXB-63 C32 32A 2P MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging and printed documentation: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePositive isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous linked operation of two poles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClear red\/green contact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot provided by this MCB:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current\/earth-leakage protection, surge protection, over\/under-voltage protection or arc-fault protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NXB-63 compliant standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 10963.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on the supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark visible on the supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NXB-63 certificate published by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE RoHS Declaration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NXB-63 declaration published by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NXB-63 certificate published by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKC, 2P C32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExact configuration certificate listed by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSNI, NOM, EAC, SII\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT for the NXB-63 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT for the NXB-63 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCarbon Footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT for the NXB-63 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSAA, SIRIM, TÜV, UKCA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertificates listed on CHINT’s official product page; regional applicability must be checked\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The official NXB-63 product page, catalog and user manual reviewed for this listing do not state a model-specific warranty duration. Confirm the applicable ExSolar.pk or authorized CHINT distributor warranty before publishing a term.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":52501783183640,"sku":null,"price":1999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_2.png?v=1786267063"},{"product_id":"projoy-32a-2-pole-ac-breaker","title":"PROJOY PEM1LE-63 C32 32A 1P+N Type A AC RCBO","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROJOY Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePEM1LE-63 C32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Power Distribution \/ Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic RCBO — residual-current circuit breaker with overcurrent protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P+N (commonly marketed as a two-pole or L+N breaker)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePEM Series; PEM1LE-63 electronic Type A RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShopify classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC Protection Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe PROJOY PEM1LE-63 C32 is a 32A, 1P+N electronic Type A RCBO for AC 230V circuits. It combines residual-current, overload and short-circuit protection in one compact TH35-7.5 DIN-rail device, with a C tripping curve, 6kA breaking capacity and flexible top or bottom incoming wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eProtect single-phase AC circuits with one compact device. The PROJOY PEM1LE-63 C32 combines the functions of an MCB and residual-current protective device, helping protect connected circuits against overloads, short circuits and residual-current faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis C32 variant is rated at 32A and uses a C tripping curve for circuits with moderate inrush current. Its 1P+N construction switches the line and neutral in a compact DIN-rail format, while the dedicated test button supports routine functional checking. PROJOY specifies AC 230V operation, 6kA breaking capacity, Type A residual-current detection, IP20 protection and support for incoming wiring from either the top or bottom.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe PEM1LE-63 series is intended for residential, commercial and industrial low-voltage distribution systems, including distribution boards and control panels associated with solar and backup installations. Installation and device selection must be completed by a qualified electrician. The exact residual-current sensitivity of the supplied unit must be confirmed from its legible nameplate or packaging before installation because the official series is offered in 30mA, 50mA and 100mA variants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A C-curve RCBO configuration identified by the C32 model marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombines residual-current, overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectronic Type A residual-current detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1P+N arrangement for single-phase line and neutral circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated for AC 230V operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum breaking time of 0.1 seconds at rated residual operating current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact IP20 enclosure for distribution-board installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTH35-7.5 DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports top or bottom incoming wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDedicated test button for routine functional checks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial series electrical life of 6,000 cycles and mechanical life of 10,000 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ verified value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROJOY Electric Co., Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePEM1LE-63 C32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 230V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P+N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-current type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve, 5In–10In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact rated residual operating current of attached unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series residual-current options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30mA \/ 50mA \/ 100mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum breaking time at IΔn\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTH35-7.5 DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncoming wiring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop or bottom\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial offices, shops and hospitality circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial low-voltage branch circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLighting, socket and appliance circuits selected within the device rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC distribution boxes and control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side circuit protection in solar PV installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackup and hybrid-system AC distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer does not publish exact retail package contents for this model on the official product page.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePROJOY PEM1LE-63 C32 RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct identified; package quantity Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation guide \/ certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current \/ earth-leakage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType A detection for sinusoidal AC and pulsating DC residual-current components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLine and neutral circuit switching through the 1P+N arrangement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual test function through the front test button\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 61009-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified by the official PROJOY RCBO guide\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial RCBO CE document is listed on the manufacturer product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUKCA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty period for the PROJOY PEM1LE-63 C32: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROJOY","offers":[{"title":"Default Title","offer_id":52501797994776,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_3.png?v=1786269563"},{"product_id":"tomzn-40a-2-pole-ac-breaker","title":"TOMZN TOB1-63H C40 40A 2-Pole AC Miniature Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H C40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Power Distribution \/ Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Miniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H \/ TOB1-63 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShopify classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC Protection Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB1-63H C40 is a 40A, two-pole AC miniature circuit breaker with a C tripping curve. The attached unit is marked for 400V AC operation and 6kA breaking capacity, providing overload and short-circuit protection for suitable low-voltage distribution circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eProtect AC distribution circuits with the compact TOMZN TOB1-63H C40 miniature circuit breaker. This two-pole C-curve model is rated at 40A and uses a mechanically linked handle so both poles operate together.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN positions the TOB1-63 series for lighting and motor distribution systems requiring overload and short-circuit protection. The manufacturer states that multipole variants are intended for AC 50\/60Hz circuits up to 415V and that the enclosure components use high fire-resistant, shock-resistant plastic. The supplied product label identifies this exact C40 unit as 400V AC with a 6000A breaking capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker can also be used for infrequent switching of electrical equipment and lighting circuits within its rated conditions. Selection, coordination and installation must be completed by a qualified electrician according to the applicable wiring rules and the requirements of the connected circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact TOB1-63H C40 model marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e40A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole construction with linked operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC tripping characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC marking on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA \/ 6000A breaking-capacity marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo front status windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour screw terminals for the two switched poles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh fire-resistant and shock-resistant plastic construction stated by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable series design for 50Hz\/60Hz AC distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ verified value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H C40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Miniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage marking on attached unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P: 240V AC; 2P\/3P\/4P: up to 415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz \/ 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaking capacity marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000A \/ 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload and short circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitching\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuitable for infrequent switching under normal conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh fire-resistant and shock-resistant plastic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo front mechanical status windows\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal arrangement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFour screw terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpulse withstand voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential AC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial low-voltage distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLighting distribution circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMotor distribution circuits selected within the breaker rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl panels and branch-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in compatible solar, backup and hybrid-system distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInfrequent circuit switching under normal operating conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe exact retail package contents are not published on the official product page.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN TOB1-63H C40 2P MCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct identified; package quantity Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation instructions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous operation of both poles through the linked handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual ON\/OFF isolation function within the manufacturer's stated operating conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis model does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provide verified residual-current, earth-leakage, surge, overvoltage or undervoltage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified from the attached manufacturer label; official page states IEC 60898 compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStated on the official TOMZN product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 10963.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified from the attached manufacturer label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on the attached product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN makes a general website claim for its circuit breakers; exact model certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB \/ TÜV \/ UKCA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty period for the TOMZN TOB1-63H C40: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52501833646360,"sku":null,"price":1699.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_4.png?v=1786271779"},{"product_id":"cnc-40a-2-pole-ac-breaker","title":"CNC YCBZ-40 40A 2-Pole Manual Changeover Switch","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCBZ-40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A, 2-pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual changeover switch \/ switch-disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Voltage \u0026gt; Final Distribution \u0026gt; Change-Over Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC source-selection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact Form\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II \/ 1–0–2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCBZ-40 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The attached product is not a conventional MCB. It is a manually operated changeover switch for selecting between two AC sources. No automatic transfer, overload, short-circuit, earth-leakage or surge-protection function is claimed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC YCBZ-40 is a 40A, 2-pole manual changeover switch for controlled I–0–II selection between two AC power sources. Designed for 35 mm DIN-rail mounting, it supports 240\/415V AC systems, AC-22A utilization and IEC 60947-3 switch-disconnector applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBuilt for compact low-voltage distribution boards, the CNC YCBZ-40 provides deliberate manual transfer between two AC supplies through a mechanically linked 2-pole operating handle. Its three-position 1–0–2 contact form gives users a defined centre-off position between Source I and Source II, making it suitable for professionally designed grid\/generator, grid\/inverter and other backup-source selection panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 40A version is rated by CNC for 240\/415V AC at 50\/60Hz, with AC-22A utilization, IP20 protection and 35 mm DIN-rail installation. CNC lists 1,500 electrical operating cycles and 8,500 mechanical cycles for the YCBZ-40 series. Correct cable sizing, upstream circuit protection and installation by a qualified electrician are required for a complete safe system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e40A rated-current variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2-pole mechanically linked switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual I–0–II \/ 1–0–2 source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre-off position between the two supply positions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e240\/415V AC official series rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz rated frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-22A utilization category\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60947-3 switch-disconnector standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e10 mm² terminal\/cable capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e35 mm DIN-rail mounting with fast-clip mechanism\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1,500 electrical and 8,500 mechanical operating cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ Verified Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCBZ-40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P, 40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual changeover switch \/ switch-disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240\/415V~ (official product page, catalogue and manual)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarking Visible on Supplied Product Image\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\/400V~\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact Form\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–0–2 \/ I–0–II\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUtilization Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC-22A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-3; supplied unit is marked IEC\/EN 60947-3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,500 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Operating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5°C to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2,000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal \/ Cable Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Conductor Cross-Section for 40A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Terminal Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 N·m for 20A–63A ratings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail, EN 60715, fast-clip device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified — official sources show conflicting dimensional presentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Overload Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified \/ not claimed for this switch-disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Short-Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified \/ not claimed for this switch-disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Earth-Leakage Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified \/ not claimed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Transfer Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo — manual operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential backup-power distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial low-voltage source-selection panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual grid-to-generator selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual grid-to-inverter selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackup supply isolation and transfer arrangements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSingle-phase systems requiring 2-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar and hybrid installations on the AC distribution side\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall industrial and agricultural control panels within the verified electrical ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × CNC YCBZ-40 40A 2-pole manual changeover switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted instruction sheet\/manual: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail or enclosure hardware: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables, lugs and upstream protection devices: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 finger-protection degree for the device enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked 2-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre-off I–0–II contact arrangement for deliberate manual source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitch-disconnector function under normal circuit conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot integrated or not verified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e overload protection, short-circuit protection, residual-current\/earth-leakage protection, surge protection and automatic source transfer. Appropriate upstream protective devices must be selected separately by a qualified system designer or electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official product page, catalogue and manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark visible on the supplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry-specific conformity approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC's official warranty policy states \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24 months from the date of manufacture for other low-voltage apparatus\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The period may be changed by the signed customer contract. Local seller\/distributor warranty, claim process and exclusions should be confirmed before purchase.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52501877555480,"sku":null,"price":1950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_5.png?v=1786273741"},{"product_id":"chint-40a-2-pole-ac-breaker","title":"CHINT NXB-63 C40 40A 2-Pole 6kA AC Miniature Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNXB-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P, C40, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Order Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e814096\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Voltage \u0026gt; IEC \u0026gt; Final Power Distribution \u0026gt; MCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC circuit-protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNXB-63 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThis is a thermal-magnetic MCB for overload and short-circuit protection. It is not an RCCB or RCBO and does not provide residual-current\/earth-leakage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NXB-63 C40 is a 40A, 2-pole, C-curve AC miniature circuit breaker with 6kA breaking capacity. Designed for IEC final-distribution systems, it provides overload, short-circuit and positive-isolation functions with 35 mm DIN-rail mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NXB-63 C40 2P MCB provides dependable thermal-magnetic protection for low-voltage AC final-distribution circuits. Its mechanically linked two-pole design disconnects both poles together, while the C tripping characteristic is intended for mixed and moderately inductive loads where normal inrush current is higher than purely resistive circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCHINT officially lists this exact 2P C40 variant for AC 380\/400\/415V operation with 6kA breaking capacity and IEC\/EN 60898-1 compliance. The compact two-module device mounts on a TH35-7.5 DIN rail, supports top or bottom cable entry and includes front status windows for clear ON\/OFF indication. Installation and circuit selection must be completed by a qualified electrician according to the actual load, prospective fault current and local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e40A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve thermal-magnetic tripping characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePositive isolation function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC 380\/400\/415V exact-variant rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60898-1 compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGreen\/red ON\/OFF contact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTH35-7.5 DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20,000 mechanical and 10,000 electrical operating cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ Verified Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNXB-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Description\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNXB-63 2P C40 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Order Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e814096\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous Magnetic Trip Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 380\/400\/415V for exact 2P C40 variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarking Visible on Supplied Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V~, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Short-Circuit Breaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Service Short-Circuit Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, short circuit, positive isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional Marking Visible\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 10963.1; CCC mark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5W per pole at 40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 direct mounting; IP40 inside distribution box\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Ambient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eII\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eII and III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–25mm² copper conductor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Copper Cable for 40A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Withstand Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Entry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop or bottom\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTH35-7.5 DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e81mm high × 36mm wide × 76.8mm deep\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.09kg per pole; approximately 0.18kg for 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified; no active cooling specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-Current Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential final-distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial electrical panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight-industrial distribution circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLighting and socket circuits within the verified rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMixed and moderately inductive AC loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBranch-circuit overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole AC circuit isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar and hybrid installations on the protected AC distribution side\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplication restriction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CHINT's manual states that the product is not suitable for direct starting of high-inductive or high-capacity loads such as large fans, motors, electric-heating equipment and capacitor cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × CHINT NXB-63 C40 40A 2P MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual or certificate: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables, lugs and enclosure: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA fault-current breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePositive isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked two-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eON\/OFF contact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 direct-mounted enclosure protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot provided:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current\/earth-leakage protection, surge protection, arc-fault protection, automatic transfer or over\/under-voltage protection unless separate compatible accessories\/devices are installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSNI\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNOM\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSII\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCarbon Footprint Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified for NXB-63 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark visible on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty duration for this exact NXB-63 variant: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Confirm the applicable Pakistan distributor or seller warranty before publishing a fixed warranty period.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":52501980053784,"sku":null,"price":1999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_6.png?v=1786275182"},{"product_id":"mora-63a-2-pole-ac-breaker","title":"MORA AES-60H C63 63A 2-Pole 400V AC Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIdentification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC circuit breaker \/ MCB-form device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-voltage AC circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC circuit-protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGeneration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eIdentification is based on the supplied product image. The front label clearly shows MORA Electric, AES-60H, C63, 400V~, IEC 60947-2 and Icu=10kA. An official model-specific product page, datasheet or manual was not publicly verifiable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-60H C63 is a 63A, 2-pole AC circuit breaker marked for 400V AC operation, IEC 60947-2 and a 10kA ultimate short-circuit breaking capacity. Its compact two-module design features a mechanically linked orange operating handle and screw-terminal connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA Electric AES-60H C63 is a compact two-pole circuit breaker intended for installation in compatible low-voltage AC distribution equipment. The supplied unit is marked C63 and 400V~, with IEC 60947-2 and Icu=10kA printed on its front label.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts mechanically linked double handle allows both poles to be operated together, while the four screw-terminal positions support a conventional two-pole wiring arrangement. The breaker should be selected and installed by a qualified electrician after confirming the system voltage, prospective fault current, conductor size, enclosure, installation conditions and applicable local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis product must not be described or used as an earth-leakage breaker, surge protector or DC breaker unless separate official documentation confirms those functions. It is intended for AC-side applications only based on the supplied 400V~ marking.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A current marking (C63)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked double operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC front-label marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIcu 10kA front-label marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60947-2 standard marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAES-60H model identification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact two-module form factor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour screw-terminal positions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClear ON\/OFF operating symbols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhite molded housing with high-visibility orange handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for compatible AC distribution-panel applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC circuit breaker \/ MCB-form device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A, based on C63 marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC marking visible; official curve range Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Short-Circuit Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10kA marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService Short-Circuit Breaking Capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2 marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail-style mounting area visible; exact rail specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew terminals visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive \/ no active cooling visible; official specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable \/ none visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-Current Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified; no test button or residual-current marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential AC distribution boards, subject to professional system design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial AC distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight-industrial AC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole AC circuit switching and isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side distribution in solar or hybrid installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenerator and backup-system AC distribution, subject to correct coordination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Do not install this unit in a DC circuit. Application suitability, cable size, fault level and protective coordination must be confirmed by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × MORA Electric AES-60H C63 63A 2P AC circuit breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail, cables, lugs and enclosure: Not Verified \/ not shown\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Feature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10kA ultimate short-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIcu=10kA marking visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified from an official model-specific document\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit tripping mechanism\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified beyond the Icu marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-pole linked operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisually Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-current \/ earth-leakage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified; do not advertise as RCCB or RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArc-fault protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver\/under-voltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThird-party test certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty duration and Pakistan claim procedure: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52502191178008,"sku":null,"price":1699.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_7.png?v=1786276215"},{"product_id":"tomzn-63a-2-pole-ac-breaker","title":"TOMZN TOB1-63H C63 63A 2-Pole 400V 6kA AC Miniature Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-voltage AC circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC circuit-protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied image matches TOMZN's official TOB1-63H C-curve AC MCB series. Its front label shows C63, 2P, 400V~, 6000A, IEC\/EN 60898-1, GB\/T 10963.1, CE and CCC markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB1-63H C63 is a 63A, 2-pole, C-curve AC miniature circuit breaker with a 6kA breaking-capacity marking. Designed for compatible low-voltage AC distribution systems, it provides overload and short-circuit protection with a mechanically linked double-pole operating handle.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB1-63H C63 2P MCB is designed for overload and short-circuit protection in compatible AC lighting and motor-distribution systems. TOMZN officially specifies the TOB1-63H C-curve series for AC 50\/60Hz service, with single-pole versions for 240V circuits and two-, three- and four-pole versions for circuits up to 415V.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis supplied two-pole unit is marked C63, 400V~ and 6000A. Its mechanically linked blue handle operates both poles together, while the compact two-module enclosure supports installation in a compatible distribution board. TOMZN describes the series housing and components as using high fire-resistant and shockproof plastic.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker may also be used for infrequent switching of electrical equipment and lighting circuits under normal conditions. Final selection and installation must be completed by a qualified electrician after checking the system voltage, prospective fault current, conductor size, enclosure and local electrical regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated-current variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve tripping characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA breaking-capacity marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC marking on supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC 50\/60Hz series operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60898 and IEC 60947 series compliance stated by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60898-1 marking on supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-resistant and shockproof plastic construction stated by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for compatible lighting and motor-distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ Verified Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC marking on supplied unit; official series supports 2P up to 415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Breaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA \/ 6000A marking on supplied unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Service Short-Circuit Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload and short circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially Stated Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60898 and IEC 60947\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Markings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1; GB\/T 10963.1; CE; CCC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh fire-resistant and shockproof plastic stated by TOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNormal Switching Use\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfrequent switching of electrical equipment and lighting circuits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail-style mounting visible; exact rail specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew terminals visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive \/ no active cooling specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-Current Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified; this product is an MCB, not identified as an RCCB or RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential AC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial AC distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLighting-distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible motor-distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBranch-circuit overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInfrequent switching of electrical equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in solar and hybrid installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This is an AC MCB. Do not install it in a DC circuit. Installation, conductor selection and protective coordination must be handled by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × TOMZN TOB1-63H C63 63A 2P AC MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables, lugs and enclosure: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA breaking-capacity marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked two-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eON\/OFF position marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-resistant and shockproof plastic construction stated by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot specified for this MCB:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current\/earth-leakage protection, surge protection, arc-fault protection, automatic transfer or over\/under-voltage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60898\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStated on official TOMZN product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStated on official TOMZN product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 10963.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible; model-specific certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible; model-specific certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty duration and Pakistan claim procedure for this exact variant: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52502232105240,"sku":null,"price":1750.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_8.png?v=1786277187"},{"product_id":"cnc-63a-2-pole-ac-breaker","title":"CNC YCB7-63 C63 63A 2-Pole 230\/400V 6kA AC Miniature Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB7-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-voltage AC circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC circuit-protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB7-63 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied image matches CNC Electric's official YCB7-63 MCB series. Its front label shows C63, 2P, 230\/400V~, 6000A, GB\/T 10963.1, IEC 60898-1 and CCC markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC YCB7-63 C63 is a 63A, 2-pole, C-curve AC miniature circuit breaker with 6kA rated short-circuit capacity. It provides overload and short-circuit protection in compatible 230\/400V AC distribution systems and features a linked double-pole handle, contact-status windows and 35mm DIN-rail mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YCB7-63 C63 2P MCB delivers compact protection for compatible low-voltage AC circuits. CNC officially rates the YCB7-63 series for 230\/400V AC, 50\/60Hz operation with rated currents up to 63A and B, C or D instantaneous-release characteristics. This exact supplied unit is marked C63 and 6000A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe two-pole design uses a mechanically linked red operating handle so both poles operate together. Front indication windows provide visible contact status, while CNC's terminal double-protection design, all-copper current carrier, magnetic-blow arc-extinguishing device and side ventilation grooves support reliable installation and operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker mounts on a 35mm DIN rail using a fast-clip device and accepts top or bottom connections. Final selection and installation must be completed by a qualified electrician after checking the system voltage, prospective fault current, conductor size, enclosure and local electrical regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve instantaneous release, 5–10 × In\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e230\/400V AC, 50\/60Hz operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60898-1 compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-status indication windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTerminal double-protection design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic-blow arc-extinguishing device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e35mm DIN-rail mounting with top or bottom connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ Verified Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB7-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous Magnetic Trip Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\/400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Short-Circuit Capacity (Icn)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Service Short-Circuit Capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Test Voltage, 1 Minute\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload and short circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReference Temperature for Thermal Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Ambient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5°C to +40°C, daily average ≤35°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable \/ pin-type busbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Terminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 25mm², AWG 18–3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBusbar Terminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 25mm², AWG 18–3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2N·m \/ 18in-lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 60715 35mm DIN rail, fast-clip device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop or bottom\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e78mm high × 36mm wide × 72mm deep for 2P, based on official drawing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAll-copper current carrier stated by CNC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive; side ventilation-groove design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-Current Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo residual-current function specified; not identified as RCCB or RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential AC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and non-residential buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial distribution circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnergy-industry and infrastructure installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBranch-circuit overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole AC circuit control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in solar and hybrid installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This is an AC MCB. Do not install it in a DC circuit. Installation, conductor sizing and protective coordination must be completed by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × CNC Electric YCB7-63 C63 63A 2P AC MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual or certificate: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables, lugs and enclosure: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA Icn and Ics short-circuit capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked two-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-status indication windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTerminal double protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh flame-retardant, temperature-resistant and impact-resistant enclosure design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic-blow arc-extinguishing device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot specified for this MCB:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current\/earth-leakage protection, surge protection, arc-fault protection, automatic transfer or over\/under-voltage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official product data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified on official CNC product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product; certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 10963.1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty duration and Pakistan claim procedure for this exact YCB7-63 variant: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52502266872088,"sku":null,"price":1999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_9.png?v=1786278408"},{"product_id":"chint-63a-2-pole-ac-breaker","title":"CHINT NB1-63 C63 63A 2-Pole 400V 6kA AC Miniature Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-voltage AC circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ AC circuit-protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied image matches CHINT's official NB1-63 series. Its front marking identifies the exact C63, 2-pole, 400V AC, 6000A variant manufactured to IEC\/EN 60898-1.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NB1-63 C63 is a 63A, 2-pole, C-curve miniature circuit breaker for compatible 400V AC distribution systems. It provides overload and short-circuit protection, offers 6kA rated breaking capacity, includes visible contact-position indicators and mounts on a standard 35mm DIN rail.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NB1-63 C63 2P MCB provides dependable protection and switching for compatible low-voltage AC distribution circuits. This exact supplied variant is marked C63, 2P, 400V AC and 6000A, while CHINT officially specifies 50\/60Hz operation and compliance with IEC\/EN 60898-1.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts C-curve thermal-magnetic release is intended for resistive and inductive loads with low inrush current. The two poles operate through a mechanically linked blue handle, while front contact-position windows support quick visual status checks. The device provides overload and short-circuit protection and can also be used for circuit isolation and infrequent switching under normal conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker is designed for standard 35mm DIN-rail installation, accepts top or bottom feed and supports cable or compatible busbar connections. Final product selection, conductor sizing, fault-level coordination and installation must be completed by a qualified electrician in accordance with local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve thermal-magnetic release, 5–10 × In\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC, 50\/60Hz operation for this 2P variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-position indication windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitch and isolation functionality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnergy-limiting class 3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e35mm DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTop or bottom feed connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial \/ Verified Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63, 2P, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous Magnetic Trip Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC for supplied unit; official 2P rating 400\/415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Short-Circuit Breaking Capacity (Icn)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA under IEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnergy-Limiting Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Test Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2kV for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass II and III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload and short circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitching \/ Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 operations for AC IEC\/EN application\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact-Position Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReference Temperature for Thermal Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Ambient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C, daily average ≤35°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable \/ U-type busbar \/ pin-type busbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Terminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–25mm²; AWG 18–4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBusbar Terminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 10mm²; AWG 18–8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0N·m \/ 22in-lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTH35-7.5 \/ EN 60715 35mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop or bottom feed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e82mm high × 36mm wide × 75.5mm deep for 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11kg per pole; approximately 0.22kg for 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive \/ natural convection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-Current Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot included; this product is an MCB, not an RCCB or RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight-industrial distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBranch-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResistive and low-inrush inductive loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole AC isolation and switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in compatible solar and hybrid installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This product is identified as an AC MCB. Do not use it as a substitute for a DC breaker, residual-current device or surge-protection device. Installation must be completed by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × CHINT NB1-63 C63 63A 2P AC MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual or certificate inside retail packaging: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables, busbars and enclosure: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePositive isolation \/ isolation function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnergy-limiting class 3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included or not specified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current\/earth-leakage protection, surge protection, arc-fault protection, automatic transfer, remote monitoring and over\/under-voltage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified for this supplied variant and official series documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NB1-63 series certificate\/declaration available from CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NB1-63 series certificate available from CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV \/ VDE \/ SEMKO\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NB1-63 series certificates available from CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NB1-63 series declaration available from CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial NB1-63 series declaration available from CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry-specific approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple series certificates are listed by CHINT; applicability to the supplied Pakistan-market unit is Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty duration and Pakistan claim procedure for this exact NB1-63 C63 2P unit: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":52502305440024,"sku":null,"price":1999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_10.png?v=1786279810"},{"product_id":"cnc-20a-2-pole-dc-breaker","title":"MORA AES-60H-DC C20 20A 2-Pole DC Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIdentification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequested Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20, 20A, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC miniature circuit breaker \/ DC circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExSolar Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ DC protection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve indicated by requested C20 marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant verification note: the supplied physical-product reference is marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC63\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The product visuals in this package were changed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e at the customer's instruction because the 20A version reportedly uses the same enclosure design. An official MORA datasheet or model-specific page confirming the exact AES-60H-DC C20 2P variant was not found.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-60H-DC C20 is presented as a 20A, two-pole DC circuit breaker for compatible solar and DC distribution applications. It features linked double-pole operation, polarity-marked terminals, a compact modular enclosure and DIN-rail-style installation. Exact electrical ratings for the C20 variant must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-60H-DC C20 2P DC breaker is designed in a compact two-module format for compatible direct-current circuits. Its mechanically linked orange handle operates both poles together, while numbered and polarity-marked terminals help installers follow the required DC wiring direction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied reference shows the AES-60H-DC enclosure, MORA Electric branding, a side specification label and IEC 60947-2 marking. For this Shopify listing, the original C63 front marking has been changed to C20 according to the customer's product information. Because an official MORA specification sheet for the exact C20 2P version could not be located, voltage, breaking capacity, endurance, environmental ratings and terminal limits must be confirmed from the actual unit, packaging or authorized MORA documentation before sale or installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis product should only be selected and installed by a qualified technician after confirming system voltage, prospective short-circuit current, polarity, conductor size, enclosure conditions and local electrical requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20A requested current rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole DC breaker configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC20 front marking requested for this variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked double-pole handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClearly numbered terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity-marked DC connection points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOrange operating handle for high visibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSide specification-label area\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail-style installation format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for professionally designed DC protection assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMORA Electric AES-60H-DC series styling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status \/ Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric — visible on supplied reference\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC — visible on supplied reference\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequested Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20, 20A, 2P — supplied by customer; official variant page Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC circuit breaker \/ DC MCB — supplied by customer and consistent with device markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A — customer-provided; official C20 datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P — visually verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve indicated by C20 marking; official trip-range data Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V DC is printed on the supplied C63 reference; applicability to the requested C20 variant Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Breaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIcu 10kA is printed on the supplied C63 reference; applicability to the requested C20 variant Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2 marking visible; certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable for DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity-sensitive terminal markings visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Numbering\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1, 2, 3 and 4 visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e“Cu only” marking visible on reference\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntended overload and short-circuit protection; official C20 performance data Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation \/ Switching\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual linked two-pole operation visible; official isolation rating Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail-style form factor; exact rail standard Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMust follow printed polarity and terminal markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for exact C20 variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for exact C20 variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive \/ natural convection by product design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Applicable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResidual-Current Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified; do not treat as RCCB or RCBO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot included \/ Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar PV DC protection assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery and energy-storage DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC combiner and protection boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEquipment-level DC isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRenewable-energy installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial DC control circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSelection warning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Do not use the breaker until the exact unit's voltage rating, breaking capacity, polarity diagram and conductor requirements have been checked against the intended system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × MORA AES-60H-DC C20 20A 2P DC breaker — requested product configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual or certificate: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCables, lugs, busbars and enclosure: Not Included \/ Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended overload-current protection — exact C20 trip data Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended short-circuit-current protection — exact C20 breaking data Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked two-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity-marked terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual ON\/OFF operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarning label on enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included or not specified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e residual-current protection, surge protection, arc-fault protection, remote monitoring, automatic transfer and over\/under-voltage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied enclosure; official certificate for C20 variant Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty duration and Pakistan claim procedure for the exact AES-60H-DC C20 2P variant: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52503318331672,"sku":null,"price":1650.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_5f5569d3-88fa-4a85-8ee5-9f5eed7d77bd.png?v=1786340500"},{"product_id":"solis-8kw-hybrid-inverter","title":"Solis S6-EH1P8K-L-PLUS 8kW Hybrid Inverter","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolis (Ginlong Technologies)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS6-EH1P8K-L-PLUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-phase low-voltage hybrid inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHybrid \u0026amp; Off-grid Inverter \/ Residential Energy Storage Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolis S6, L-PLUS series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating role\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-grid, hybrid and backup\/off-grid operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSolis S6-EH1P8K-L-PLUS 8kW Single-Phase Hybrid Inverter IP66\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Solis S6-EH1P8K-L-PLUS is an 8kW single-phase, low-voltage hybrid inverter designed for residential solar-plus-storage systems. It supports 40–60V lithium-ion or lead-acid batteries, two MPPTs with four PV string inputs, an 8kW backup output, generator and AC-coupling functions, IP66 protection, and local control through a 7-inch colour display and Bluetooth app connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBuilt for flexible residential energy storage, the Solis S6-EH1P8K-L-PLUS combines an 8kW grid output with an 8kW battery charge\/discharge stage and a dedicated backup output. Its two MPPT trackers accept up to four PV strings, while a maximum usable PV input power of 12.8kW allows a 1.6 DC-to-AC ratio for stronger solar harvesting across changing conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe inverter works with compatible 40–60V lithium-ion and lead-acid batteries and supports up to 190A charge\/discharge current. A dedicated smart port can be configured for a generator, smart load or AC-coupled grid-tied inverter. Backup transfer is rated below 4ms, and the backup output can supply twice rated power for 10 seconds to accommodate demanding starting loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor system management, the S6 platform provides a 7-inch colour LCD, built-in Bluetooth, RS485 and CAN communication, with optional Wi-Fi, GPRS or LAN monitoring through SolisCloud. Its IP66 enclosure, intelligent cooling and comprehensive electrical protections make it suitable for indoor or outdoor installation when installed in accordance with the official manual and local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8kW rated single-phase grid and backup output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-voltage 40–60V battery platform for lithium-ion or lead-acid batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8kW maximum battery charge\/discharge power and up to 190A current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo MPPT trackers with four PV string inputs on the 8kW model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e12.8kW maximum usable PV input power, equal to a 1.6 DC\/AC ratio\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLess than 4ms backup transfer time for critical loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e200% backup overload capability for 10 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenerator, smart-load and AC-coupling functions through the configurable smart port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to six compatible units can operate in parallel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e7-inch colour LCD plus built-in Bluetooth local commissioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS485 and CAN communication; optional Wi-Fi, GPRS and LAN monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP66 enclosure with intelligent cooling for indoor or outdoor installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS6-EH1P8K-L-PLUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum apparent grid output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle phase, 1\/N\/PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220V \/ 230V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz \/ 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated grid output current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.4A at 220V \/ 34.8A at 230V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrid voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e187–253V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrid frequency range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–55Hz \/ 55–65Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;0.99; adjustable 0.8 leading to 0.8 lagging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrid output THDi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum usable PV input power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12,800W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum PV input voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated PV voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePV start-up voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90–435V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFull-load MPPT voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–435V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMPPTs \/ maximum PV strings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 \/ 4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum PV input current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A \/ 32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum PV short-circuit current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A \/ 40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40–60V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported battery type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium-ion \/ lead-acid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum battery charge\/discharge power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum battery charge\/discharge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery communication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN \/ RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated backup output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum backup output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup transfer time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;4ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup overload capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2× rated power for 10 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum AC pass-through current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e96.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEU efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e96.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery charged by PV \/ AC maximum efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95.3% \/ 93.9%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery discharged to AC maximum efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e93.8%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay and local control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-inch colour LCD, status indicators, Bluetooth + app\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485, CAN; optional Wi-Fi, GPRS, LAN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntelligent cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–95%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndoor and outdoor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e335 × 560 × 253mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.5kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePV connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMC4 plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery \/ AC connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 years; official extension available up to 20 years, subject to Solis terms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar self-consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHome battery storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCritical-load backup power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHybrid on-grid solar systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff-grid and weak-grid residential systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenerator-assisted backup systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmart-load control and load shedding\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC coupling for an existing grid-tied PV installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMulti-inverter parallel systems, subject to official design requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe official V1.3 manual lists:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolis S6 hybrid inverter ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBack plate ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFastening screws ×2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eParallel communication cable ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRJ45 connectors ×4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCT ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWLAN stick ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC connectors for the 8kW model ×4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExpansion bolts ×4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuick Installation Manual ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSDM120M meter ×1 — optional, not standard in every package\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ePackage contents can vary by market or distributor; verify the shipped carton before listing the optional meter as included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGround-fault monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC reverse-polarity protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated DC disconnect switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurge protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput over-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInsulation-resistance monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAnti-islanding protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery overvoltage and undervoltage protection functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC and AC over-current fault monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-temperature and low-temperature protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated AFCI arc-fault protection — listed as optional in the specification table; confirm the supplied SKU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection class \/ overvoltage category: Class I; Category II for PV and battery; Category III for mains, backup and generator ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial Solis documents for this series list or provide certification for the following standards. Grid-code applicability depends on the destination market and firmware configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 62109-1 and IEC\/EN 62109-2 — inverter safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 61000-6-2 and EN 61000-6-3 — EMC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62116 — anti-islanding\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61727 — utility interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60068 — environmental testing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61683 — efficiency measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50530 — overall efficiency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE Declaration of Conformity for S6-EH1P(3-8)K-L-PLUS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional regional grid standards listed by Solis include NRS 097-2-1, G98, MEA, PEA, NBR 16149 and NBR 16150\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial standard warranty: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The official manual states that warranty extension is available up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20 years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to Solis registration, purchase, country availability and warranty terms. Confirm Pakistan-specific extension pricing and eligibility with Solis or an authorized distributor before promising an extended term to the customer.\u003c\/span\u003e\u003c\/p\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":52508283273496,"sku":null,"price":334999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_1_c1c69975-ba61-4f7b-a74f-ef3bc59e59c7.png?v=1786455135"},{"product_id":"solis-12kw-single-phase-hybrid-inverter-ip66","title":"Solis S6-EH1P12K03-NV-YD-L 12kW Single-Phase Hybrid Inverter IP66","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSOLIS \/ Ginlong Technologies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS6-EH1P12K03-NV-YD-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS6-EH1P(9.9–18)K03-NV-YD-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnergy Storage Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-phase low-voltage hybrid inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-grid and off-grid \/ backup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType 4X \/ IP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSolis S6-EH1P12K03-NV-YD-L 12kW Single-Phase Hybrid Inverter IP66\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Solis S6-EH1P12K03-NV-YD-L is a 12kW single-phase, low-voltage hybrid inverter for residential and light-commercial energy-storage systems. It supports 40–60V lithium-ion or lead-acid batteries, 3 MPPTs with 6 PV strings, generator and smart-load integration, less than 10ms backup switching and an IP66 outdoor-rated enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBuilt for high-capacity single-phase solar and storage installations, the Solis S6-EH1P12K03-NV-YD-L combines 12kW grid output with flexible low-voltage battery support and advanced energy-management functions. Its three independent MPPT trackers accept up to six PV strings, helping installers manage multiple roof orientations and modern high-current PV modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe inverter supports both grid-connected and backup operation, with a backup transfer time below 10ms. Generator input, smart-load control, AC coupling and parallel operation provide added flexibility for homes and businesses requiring dependable energy management. A 7-inch industrial LCD, built-in Bluetooth and SolisCloud-compatible communications simplify local setup and remote monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor demanding installations, the unit provides a Type 4X \/ IP66 enclosure, smart-fan cooling, integrated AFCI, DC and AC surge protection, ground-fault detection and residual-current monitoring. The official 12kW model is rated for up to 19.2kW of usable PV input and 250A maximum battery charge\/discharge current.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e12kW rated single-phase hybrid inverter output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e40–60V low-voltage battery operating range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with lithium-ion and lead-acid batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e3 independent MPPTs supporting up to 6 PV strings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 19.2kW usable PV input power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum 250A battery charge\/discharge current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLess than 10ms backup switching time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports grid, backup, generator, smart-load and AC-coupling functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 6 inverters may be operated in parallel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e200% backup overload capability for 10 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType 4X \/ IP66 enclosure with smart-fan cooling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e7-inch industrial LCD, Bluetooth and SolisCloud monitoring support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS6-EH1P12K03-NV-YD-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInverter type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-phase low-voltage hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated AC output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 \/ N \/ PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220V \/ 230V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz \/ 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrid voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e187–253V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrid frequency range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–55Hz \/ 55–65Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated grid output current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e54.5A at 220V \/ 52.2A at 230V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrid current THDi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;3%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;0.99; adjustable 0.8 leading to 0.8 lagging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum usable PV input power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum PV input voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e550V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated PV voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80–520V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFull-load MPPT voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e166–450V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMPPTs \/ maximum PV strings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 \/ 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum PV input current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A \/ 40A \/ 40A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum short-circuit current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50A \/ 50A \/ 50A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum input power per MPPT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium-ion \/ lead-acid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40–60V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum charge\/discharge power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum charge\/discharge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery communication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN \/ RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup rated output power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup rated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eL \/ N \/ PE, 220V \/ 230V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup rated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz \/ 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup switching time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;10ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup overload\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 × rated power for 10 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum parallel units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e97.6%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEU efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e97.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay \/ local setup\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-inch LCD; LED + Bluetooth + app\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485, CAN; optional cellular, Wi-Fi and LAN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePV \/ battery connections\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMC4 plug \/ terminal block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSmart-fan cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTopology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransformerless\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType 4X \/ IP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e459 × 845 × 313mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55.5kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 years; extendable to 20 years\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge residential solar and battery systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVillas, farmhouses and multi-storey homes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight-commercial premises and offices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShops, clinics and small facilities requiring backup power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrid-connected solar self-consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhole-home or essential-load backup systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenerator-assisted hybrid systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmart-load and AC-coupled solar applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems requiring multiple roof orientations or six PV strings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe official user-manual packing list shows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolis hybrid inverter × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBack plate × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFastening screws × 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExpansion bolts × 4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eParallel communication cable × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRJ45 connectors × 4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCT, 200A \/ 50mA × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWL stick × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC connectors × 6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBluetooth antenna × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuick Installation Manual × 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeter SDM120M × 1 — optional, not confirmed as standard box content\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFinal contents can vary by regional package; verify the shipment before publishing a bundle claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC reverse-polarity protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC Type II surge protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC Type III surge protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGround-fault detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current monitoring unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated AFCI 2.0 DC arc-fault protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput over-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV-only operation support where specified by Solis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection Class I\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOvervoltage Category II for PV and battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOvervoltage Category III for mains, backup and generator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE conformity documentation available for the S6-EH1P(9.9–16)K03-NV-YD-L family\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC \/ EN 62109-1 and IEC \/ EN 62109-2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 61000-6-2 and EN 61000-6-3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62116\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61727\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60068\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61683\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50530\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50549-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNRS 097-2-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 63027 documentation available for integrated AFCI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial manual warranty: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 years standard, extendable to 20 years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Extension availability, registration requirements, labour coverage and local Pakistan terms must be confirmed with the authorised Solis distributor.\u003c\/span\u003e\u003c\/p\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":52509918331160,"sku":null,"price":534999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_2_8c386c77-e251-4420-8e2f-8fe61e46eab8.png?v=1786519535"},{"product_id":"sunwoda-16kwh-lithium-battery","title":"Sunwoda Atrix Max+ 16kWh 51.2V LFP Battery — Atrix Max-16L-PK","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSunwoda Energy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Pakistan model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix Max-16L-PK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix Max+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium battery \/ residential energy storage system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery chemistry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLFP \/ LiFePO4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16kWh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51.2V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndoor, floor-mounted; optional wall mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e this is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e16kWh\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e energy-storage battery, not a 16kW battery. The supplied image visually matches the Atrix Max+ cabinet, but its product nameplate is not visible.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSunwoda Atrix Max+ 16kWh 51.2V LFP Battery — Atrix Max-16L-PK\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Sunwoda Atrix Max-16L-PK is a 16kWh low-voltage LFP battery developed for residential, agricultural, backup and small-commercial energy-storage systems. It provides 100% usable depth of discharge, 51.2V nominal voltage, up to 220A charge\/discharge current, integrated Wi-Fi, CAN\/RS485 communication and expansion to 512kWh with up to 32 batteries in parallel.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for high-capacity energy storage and long-term reliability, the Sunwoda Atrix Max+ combines a 16kWh LFP battery with intelligent monitoring and flexible system expansion. Its 51.2V architecture is intended for compatible low-voltage hybrid inverters, while CAN 2.0 and RS485 interfaces support coordinated battery-to-inverter communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Pakistan-specific Atrix Max-16L-PK model offers 16kWh nominal and usable energy at 100% DOD. It is rated for 157A continuous charge and discharge, with a maximum charge\/discharge current of 220A and a 300A peak output for five minutes. Up to 32 units can be connected in parallel, expanding total storage capacity to 512kWh.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated casters simplify movement during installation, and optional wall mounting is supported. The enclosure is intended for indoor installation and uses natural-convection cooling for quiet operation. Integrated Wi-Fi enables monitoring, while the official Atrix Max+ platform supports real-time status visibility, remote maintenance and upgrades.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e16kWh nominal energy and 16kWh usable energy at 100% DOD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafe lithium iron phosphate battery chemistry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e314Ah LFP cells\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e51.2V nominal low-voltage architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e157A rated charge and discharge current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e220A maximum charge and discharge current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e300A peak output current for five minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAN 2.0 and RS485 communication interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated Wi-Fi monitoring module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 32 batteries in parallel for a maximum 512kWh system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated casters with optional wall-mount installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial Atrix Max+ platform rating of 10,000 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix Max-16L-PK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAtrix Max+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium iron phosphate \/ LFP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCell capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e314Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16kWh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUsable energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16kWh at 100% DOD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51.2V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharge\/discharge cut-off voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e44.8–57.6V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated charge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e157A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated discharge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e157A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum charge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum discharge current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeak output current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300A for 5 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN 2.0 \/ RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWi-Fi module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eParallel expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum 32 units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum expanded energy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512kWh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndoor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFloor-mounted; wall-mounted optional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCasters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDischarge temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharge temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–95%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural convection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBelow 4,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 × 970 × 265mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCycle rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 years; subject to official warranty terms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar energy storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHome backup-power systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-voltage hybrid inverter systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFarmhouses and agricultural facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShops, offices and small-commercial properties\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePeak-load shifting and self-consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff-grid and weak-grid energy systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExpandable multi-battery storage installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility with a specific inverter brand or model must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial packing-list information for the Atrix Max-16L-PK was not published in the manufacturer sources reviewed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBox contents: Not Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore publishing a bundle claim, confirm whether the shipment includes battery cables, communication cables, mounting hardware, manuals or any separate accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafe LFP cell chemistry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC switch for safer installation and operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection for indoor installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery-management functions beyond the published information: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection details: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-current protection thresholds: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-temperature protection thresholds: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAerosol fire extinguisher on the Pakistan model: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62619\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUN 38.3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL 1973: Not Verified for Atrix Max-16L-PK\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial Pakistan brochure warranty: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6 years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to Sunwoda warranty terms. Local registration, labour coverage, transport costs and Pakistan distributor claim procedures were not verified.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunwooda","offers":[{"title":"Default Title","offer_id":52510000447768,"sku":null,"price":740000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_3_9dc977ef-f6a3-45c1-bc01-fb1517167c3a.png?v=1786521883"},{"product_id":"tomzn-dc-breaker-20a-2p-1000v","title":"TOMZN TOB7Z-63 20A 2P 1000V DC Solar MCB","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC miniature circuit breaker (DC MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A, 2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories \/ DC Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGeneration \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eIdentification is based on the supplied product image and TOMZN's official product listing. Electrical installation and breaker selection must be performed by a qualified professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB7Z-63 20A 2P 1000V DC Solar MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB7Z-63 is a 20A, 2-pole DC miniature circuit breaker designed for solar PV and other compatible DC circuits. The supplied unit is marked for 1000V DC, 6kA ultimate short-circuit breaking capacity, and IEC\/EN 60947-2, with linked double-pole operation and clear polarity markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eProtect and isolate compatible DC circuits with the TOMZN TOB7Z-63 20A 2P DC MCB. Its linked two-pole handle disconnects both poles together, while the printed polarity diagram supports correct DC wiring. The compact modular body, screw terminals and visual status windows make it suitable for professional solar distribution and control panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe photographed 20A variant is marked for a maximum rated voltage of 1000V DC and an ultimate short-circuit breaking capacity of 6kA. It is intended for correctly engineered PV and DC installations in which the system voltage, prospective fault current, cable size, polarity and coordination have been verified by a qualified installer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20A rated-current variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole linked switching and isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1000V DC marking on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate short-circuit breaking capacity marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for solar PV and compatible DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClear positive and negative polarity diagram\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo visual status indicator windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour screw-type connection terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular panel-breaker design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eON\/OFF position markings on the front\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 standard marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE marking visible on the supplied product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC miniature circuit breaker (DC MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Short-Circuit Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConformity Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Handle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanically linked double-pole handle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo front indicator windows\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes; printed on front\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail-compatible modular form visible; official mounting specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar PV array and string protection panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC combiner and distribution boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible inverter DC input circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral low-voltage DC distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery and energy-storage DC circuits only where the breaker rating, polarity, selectivity and fault-current capability have been professionally verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTelecommunications and control DC circuits within the published electrical ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial package contents: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOvercurrent \/ overload circuit interruption as a DC MCB function; exact trip curve is Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit interruption with 6kA Icu marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous two-pole disconnection through the linked handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity guidance printed on the device for correct DC installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual ON\/OFF circuit isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis product is not a surge-protection device, residual-current device or arc-fault device unless separately documented; no such functions were verified for this model.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial manufacturer warranty for this exact product: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52523421171992,"sku":null,"price":1699.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_4_876cd723-a515-4976-af64-add0f5889a69.png?v=1786862303"},{"product_id":"cnc-20a-2p-ac-breaker","title":"CNC YCB7-63N C20 20A 2P 6kA AC Miniature Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eImportant Product Classification\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot a DC breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its front label shows \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003e400V~\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003eC20\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e\u003cspan\u003eIEC 60898-1\u003c\/span\u003e\u003c\/code\u003e\u003cspan\u003e. CNC Electric's official product page and instruction manual identify the YCB7-63N series as an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAC miniature circuit breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for 230\/400V AC, 50\/60Hz circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt must not be advertised or installed as a DC breaker. A separately rated CNC DC MCB is required for DC\/PV-side circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB7-63N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20, 20A, 2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Circuit Protection \/ Final Distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB7-63N Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB7-63N C20 20A 2P 6kA AC Miniature Circuit Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YCB7-63N C20 is a 20A, two-pole AC miniature circuit breaker with C-curve thermal-magnetic tripping and a rated breaking capacity of 6kA. Designed for 50\/60Hz AC final-distribution circuits, it provides overload, short-circuit and isolation functions in residential, commercial and industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC YCB7-63N C20 2P MCB combines dependable AC circuit protection with a compact DIN-rail design. Its linked two-pole handle operates both poles together, while the front contact-status windows provide quick visual indication. The C-curve thermal-magnetic release is intended for compatible AC loads with moderate inrush current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccording to CNC Electric's official documentation, the YCB7-63N series is rated for 230\/400V AC, 50\/60Hz applications and offers overload, short-circuit and isolation functions. The supplied C20 unit is marked 400V AC and 6000A breaking capacity. Installation, cable selection and protection coordination must be completed by a qualified electrician in accordance with the official instruction manual and local electrical regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole linked operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve thermal-magnetic trip characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e230\/400V AC series rating; supplied unit marked 400V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz rated frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload, short-circuit and isolation functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFront contact-status indicator windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCable or pin-type busbar terminal compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e35mm DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60898-1 compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB7-63N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaker Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC miniature circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\/400V AC series rating; supplied unit marked 400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Breaking Capacity (Icn)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000A \/ 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelease Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal-magnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, short circuit and isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eII, III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable \/ pin-type busbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Conductor Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25mm²; AWG 18–3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN rail, EN 60715\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFollow the official instruction manual; source-side terminal orientation must be observed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot exceeding 2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for the exact C20 variant because official page and manual ranges differ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified because official page and manual values differ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential AC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial electrical panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial AC control and distribution circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-rise building final distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLighting circuits within the coordinated rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSocket and general-purpose AC circuits where C-curve protection is appropriate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-side protection in solar installations when selected by a qualified system designer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis breaker is not verified for PV-string, battery or other DC-side circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial manufacturer package contents for this exact sales unit: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied marketplace image depicts a breaker, a short DIN-rail section and two screws, but CNC Electric's official packaging documentation does not confirm that these accessories are included with every unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual circuit isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-position indication windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current, surge-protection, arc-fault and DC interruption functions are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this model.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on supplied product; official CE certification download listed by CNC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certification download listed by CNC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eINMETRO\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certification download listed by CNC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC Electric's official warranty policy states \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24 months from the date of manufacture for other low-voltage apparatus\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The warranty period may be changed by the signed customer contract. Warranty claims are handled through CNC customer service, authorized service centres or local dealers and remain subject to the official policy and exclusions.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52523433623832,"sku":null,"price":1099.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_5_2740cbd0-f2c0-4863-9d7e-09be2d7c9932.png?v=1786864713"},{"product_id":"cnc-20a-2p-600v-dc-breaker","title":"CNC YCB8s-63PVn C20 20A 2P 600V DC Solar MCB","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8s-63PVn\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20, 20A, 2P, DC600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar DC Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker (Accessory)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8s-63PVn\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-polarity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB8s-63PVn C20 20A 2P 600V DC Solar MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC YCB8s-63PVn C20 is a 20A, two-pole photovoltaic DC miniature circuit breaker designed for overload and short-circuit protection in solar DC distribution systems. This non-polar model is rated for DC600V operation and offers a standard 6kA ultimate short-circuit breaking capacity in a compact DIN-rail format.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eProtect critical solar DC circuits with the CNC YCB8s-63PVn C20 photovoltaic miniature circuit breaker. Engineered specifically for DC applications, this 20A two-pole breaker simultaneously disconnects both conductors and supports non-polar wiring, allowing supply connection from either the upper or lower terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker combines overload and short-circuit protection with manual circuit isolation. Its C-curve tripping characteristic suits correctly engineered DC circuits where controlled tolerance of normal transient current is required. The verified 2P configuration operates at up to DC600V, carries an IP20 protection rating and conforms to IEC 60947-2.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor safe selection, the breaker rating must be coordinated with the PV string, cable size, system voltage, prospective fault current and equipment manufacturer requirements. Installation should be completed by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20A rated current in the C20 configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole switching for simultaneous DC conductor isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC600V rated operating voltage for the verified 2P version\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-polarity design for flexible DC wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard 6kA ultimate short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve instantaneous tripping characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual isolation for maintenance and emergency disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60947-2 compliant photovoltaic DC breaker design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 25mm² conductor wiring capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated mechanical life of 20,000 operating cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8s-63PVn\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotovoltaic DC miniature circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Short-Circuit Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA standard; 10kA only for H version\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-polarity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUse Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Ambient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Installation Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncoming Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUpper or lower incoming lines acceptable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTH35-7.5 \/ DIN 35 rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar photovoltaic string circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV combiner and DC distribution boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC-side protection upstream of compatible solar inverters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and residential photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral DC distribution within the verified voltage and fault-current limits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery-energy-storage DC circuits only where the complete system design and protection coordination permit this breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified. The official product page and catalogue do not confirm retail package contents for this exact variant.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual DC isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous two-pole disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard 6kA ultimate short-circuit interruption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection against accidental contact with internal live parts under the applicable test conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Compliance\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEU RoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified for CNC's official DC MCB category\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact variant through a separate official certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ TÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC's official warranty policy lists a 24-month warranty period from the date of manufacture for low-voltage apparatus. Contract-specific terms may supersede the general policy. Local Pakistan reseller warranty and claim procedure: Not Verified.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52523885723928,"sku":null,"price":1950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_6_24acf23f-d46e-4207-a851-05fa8570c677.png?v=1786868386"},{"product_id":"chint-20a-2p-500v-dc-breaker","title":"CHINT NB1-63DC C20A 20A 2P 500V DC Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC20A, 20A, 2P, DC500V, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Circuit Breaker \/ Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring Polarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity-sensitive; follow the marked wiring diagram\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCHINT NB1-63DC C20A 20A 2P 500V DC Circuit Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NB1-63DC C20A is a two-pole, 20A DC circuit breaker designed to protect photovoltaic, energy-storage, telecom and other DC distribution circuits against overload and short-circuit faults. The verified 2P version is rated at DC500V with a 6kA ultimate short-circuit breaking capacity and a Type C tripping characteristic.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eProtect critical DC circuits with the CHINT NB1-63DC C20A two-pole circuit breaker. Designed for demanding direct-current applications, this compact protective device combines thermal-magnetic overload and short-circuit protection with reliable switching in a DIN-rail format.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe exact C20A configuration carries 20A rated current, uses two poles and is rated for DC500V operation. Its C-curve characteristic operates at 7–10 times rated current for instantaneous magnetic tripping, while the 6kA breaking capacity supports dependable interruption of fault current within the stated system limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe NB1-63DC series supports cable or busbar connection, contact-position indication and DIN-rail installation. Because the device is polarity-sensitive, the positive and negative conductors must be connected exactly according to the markings and official wiring diagram. Final breaker selection must be coordinated with system voltage, cable capacity, equipment requirements and prospective short-circuit current by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e20A rated current in the verified C20A configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole DC circuit interruption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC500V rated operating voltage for the 2P version\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType C instantaneous tripping characteristic, 7–10 × In\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact ON\/OFF position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCable and busbar dual-connection capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 25mm² conductor capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e35mm DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 and RoHS compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified Value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Ordering Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC 2P C20A DC500V 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT Product Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e182721\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType C, 7–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Short-Circuit Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤95%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIII\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Installation Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2,000m; derating applies above 2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 25mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLead wire and busbar compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.24kg for 2P, calculated from official 0.12kg per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar photovoltaic DC arrays and distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV combiner boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC-side inverter protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery-energy-storage DC distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEV charging DC auxiliary circuits within verified ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTelecom DC power networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and industrial DC distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified. CHINT's official product page and catalogue do not specify the retail package contents for this exact ordering variant.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA fault-current interruption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact ON\/OFF indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity markings for correct DC connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection under applicable test conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified through official CHINT declaration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified for this exact NB1-63DC C20A retail variant. Confirm the applicable warranty period and Pakistan claim procedure with the authorized supplier before publishing a warranty promise.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":52523939627288,"sku":null,"price":1850.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_7_6ff3a872-a035-4454-bacd-6fda3abf1b54.png?v=1786872239"},{"product_id":"mora-32a-2p-1000v-dc-breaker","title":"MORA AES-60H-DC C32 32A 2P 1000V DC Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIdentification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32 \/ 32A \/ 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Circuit Breaker \/ Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSource Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel and ratings observed on supplied product label; exact official datasheet not found\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMORA AES-60H-DC C32 32A 2P 1000V DC Circuit Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-60H-DC C32 is a compact two-pole DC circuit breaker marked for 32A operation, 1000V DC and 10kA ultimate breaking capacity. Its linked orange handle simultaneously operates both poles, while the printed polarity diagram supports correct DC installation. Exact technical specifications could not be confirmed through a publicly available official datasheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-60H-DC C32 provides compact two-pole switching for compatible DC distribution and solar applications. The supplied product carries visible markings for C32, 1000V DC, Icu 10kA and IEC 60947-2, with polarity indicators positioned beside the upper and lower terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts mechanically linked orange operating handle allows both poles to be switched together. The modular body is designed for installation inside an appropriate electrical enclosure by a qualified professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause MORA's exact official datasheet and installation manual for this variant could not be located, system designers must confirm operating voltage, trip curve, breaking capacity, wiring polarity, conductor size, terminal torque and environmental limits directly with MORA or an authorized distributor before installation. The breaker must never be used beyond verified system and fault-current limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC32 \/ 32A marking on the supplied product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1000V DC marking on the product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIcu 10kA marking on the product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60947-2 marking on the product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDedicated positive and negative terminal markings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted two-pole DC wiring diagram\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBright orange linked operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular enclosure format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended for compatible solar and DC distribution circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue \/ Verification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer \/ Brand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A — observed on product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P — verified from supplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V DC — observed on product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10kA — observed on product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2 — observed on product label; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC marking observed; detailed characteristic Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity-sensitive terminal markings shown on product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail-style housing visible; exact rail specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar photovoltaic DC distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV combiner and protection boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC-side protection for compatible inverters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery and energy-storage DC distribution where the complete design permits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral DC control and distribution circuits within verified ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAll applications require confirmation of voltage, current, polarity and prospective short-circuit current by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified. Official retail package contents for this exact variant could not be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMarked polarity guidance for DC wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCircuit-breaker function for compatible DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDetailed overload and short-circuit trip performance: Not Verified through an official datasheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarked on product; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified. Confirm the warranty period, authorized distributor status and Pakistan claim procedure before publishing a warranty promise.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52523954372888,"sku":null,"price":1650.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_9_f6cf6a22-366f-442d-b621-0fa3547f527a.png?v=1786873394"},{"product_id":"tomzn-32a-2p-1000v-dc-breaker","title":"TOMZN TOB7Z-63 32A 2P 1000V DC Solar MCB","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A, 2 Pole, DC 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar DC Miniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ DC Protection Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotovoltaic (PV) DC system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGeneration \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB7Z-63 32A 2P 1000V DC Solar MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB7Z-63 is a 32A, two-pole DC miniature circuit breaker intended for compatible photovoltaic DC circuits. The official TOMZN product page confirms the TOB7Z-63 series, 2P configuration, 1000V DC rating and availability of the 32A variant. Product-label markings show a 6kA breaking-capacity claim and IEC\/EN 60947-2 reference; an official downloadable datasheet or certificate for those markings was not found.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for DC-side switching and circuit protection in suitably engineered solar installations, the TOMZN TOB7Z-63 combines a two-pole linked operating handle with polarity-marked terminals in a compact modular enclosure. This listing is for the 32A, 2P, DC 1000V version identified on TOMZN's official product page.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker is suitable for use only where its voltage, current, polarity and system fault-current requirements have been checked by a qualified installer. The supplied reference image carries \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIcu 6kA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e markings; because TOMZN did not provide a downloadable official datasheet or certificate on the identified product page, these details are presented as product-label observations rather than independently certified claims.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficially identified TOMZN TOB7Z-63 series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A current variant confirmed on the official product page\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole (2P) configuration confirmed by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC 1000V product rating confirmed by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended for compatible photovoltaic DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked dual-pole operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity markings visible for correct DC wiring orientation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo status-indicator windows visible on the product face\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA breaking-capacity marking observed on the supplied product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 reference observed on the supplied product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular form suitable for compatible distribution enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual ON\/OFF switching for circuit isolation during servicing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar DC miniature circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page confirms 32A variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operational Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eObserved on supplied product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReferenced Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eObserved on supplied product label; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModular \/ DIN-rail-style enclosure visible\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExact official mounting specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Polarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity-sensitive markings visible\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar PV DC distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial solar PV DC distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV string protection where the design requires a compatible 32A two-pole DC MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar combiner boxes with compatible ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC-side isolation between PV circuits and compatible inverter equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOther engineered DC circuits only after voltage, current, polarity and fault-current coordination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis breaker must not be selected solely by current rating. The complete DC system design, conductor rating, prospective fault current, polarity and isolation requirements must be verified by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB7Z-63 32A 2P DC miniature circuit breaker: expected primary item\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting hardware: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted instructions: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging contents: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOvercurrent protection function typical of an MCB; exact trip curve and time-current characteristics: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit interruption; 6kA marking observed on the product label, official datasheet confirmation: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous linked operation of both poles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual ON\/OFF isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity markings to support correct DC connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndicator windows visible on both modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReverse-polarity protection: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurge protection: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current protection: Not Verified; this product is not presented as an RCCB\/RCBO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarking \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking observed on supplied product image; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking observed on supplied product image; official declaration Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB Scheme\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty period and warranty terms: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52524058280216,"sku":null,"price":1699.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_10_eb9f0d16-96f9-4b8e-bd1f-5a3b08c76d7b.png?v=1786885725"},{"product_id":"cnc-32a-2p-500v-dc-breaker","title":"CNC YCB8-63PV 32A 2P 500V DC Solar MCB","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A, 2 Pole, DC 500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotovoltaic DC Miniature Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ DC Protection Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar PV and compatible DC systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolarized PV version; terminal polarity must be followed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB8-63PV 32A 2P 500V DC Solar MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YCB8-63PV 32A 2-pole DC miniature circuit breaker is designed for compatible photovoltaic and DC distribution systems. This 2P variant is officially rated at DC 500V and provides overload, short-circuit and isolation functions with 6kA ultimate breaking capacity, DIN35 rail mounting and IEC\/EN 60947-2 compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEngineered for photovoltaic DC protection, the CNC YCB8-63PV offers a compact modular design for distribution boards and solar protection enclosures. The 32A, two-pole configuration uses series-connected poles for a rated operating voltage of DC 500V. Its polarized terminal markings must be followed during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker uses thermomagnetic tripping and supports overload, short-circuit and manual isolation functions. CNC officially specifies a 6kA ultimate breaking capacity, 1200V DC rated insulation voltage, 4kV impulse withstand voltage, IP20 protection and installation on a standard DIN35 rail. Selection and installation must be completed by a qualified electrical professional after checking system voltage, current, fault current, conductor size, polarity and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A rated-current option officially listed by CNC Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole polarized DC configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC 500V rated working voltage for the 2P series-connected configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate breaking capacity at the manufacturer's stated test condition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermomagnetic tripping technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual isolation and linked two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEU RoHS environmental compliance stated by the manufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular construction with DIN35 rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide official wiring-capacity range of 2.5–25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotovoltaic DC miniature circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Working Voltage, Ue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 500V for 2P series connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage, Ui\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 1200V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage, Uimp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Breaking Capacity, Icu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA at T=4ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService Breaking Capacity, Ics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% of Icu\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Curve Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB, C and K; exact supplied variant Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermomagnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN35 standard rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Categories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory II and Category III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLevel 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMoisture Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerating required above 2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5–25mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Copper Conductor for 32A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Power Consumption per Pole, 13–32A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer page contains inconsistent series figures; exact value Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer states incoming wiring may be from top or bottom; polarity and approved series wiring must still be followed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial photovoltaic installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar combiner and DC distribution boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC-side protection for compatible inverter circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial DC distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCivil and communication DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual circuit isolation during authorized maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eUse only where the system's rated voltage, operating current, conductor size, prospective fault current, polarity and isolation requirements match the breaker specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB8-63PV 32A 2P DC miniature circuit breaker: expected primary item\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting hardware: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted manual or installation sheet: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional auxiliary, alarm or shunt-release accessories: not confirmed as included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual isolation function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermomagnetic trip mechanism\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity-marked terminals for polarized DC installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional compatible auxiliary contact, alarm contact and shunt-release accessories available at series level; inclusion Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current protection: Not provided \/ this product is not an RCCB or RCBO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurge protection: Not provided \/ use a separately rated DC SPD where required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially stated by CNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEU RoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially stated by CNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product; official declaration\/certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB Scheme\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial product warranty period and warranty conditions: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52525339476248,"sku":null,"price":1850.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_11.png?v=1786943901"},{"product_id":"chint-32a-2p-500v-dc-breaker","title":"CHINT NB1-63DC 32A 2P 500V DC Circuit Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A, 2 Pole, DC 500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ DC Protection Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePV, energy storage, DC distribution, EV charging and telecom DC networks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCHINT NB1-63DC 32A 2P 500V DC Circuit Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NB1-63DC 32A two-pole DC circuit breaker provides overload and short-circuit protection for compatible DC systems. The 2P version is officially rated at DC 500V and features Type-C tripping, 6kA breaking capacity, 4kV impulse withstand voltage, IP20 protection and DIN-rail installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for modern DC power distribution, the CHINT NB1-63DC combines reliable thermomagnetic protection with a compact modular enclosure. This listing is for the 32A, two-pole version rated at DC 500V. It is suitable for properly engineered photovoltaic arrays, battery energy-storage systems, telecommunications power supplies, EV-charging equipment and other compatible DC circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker delivers overload and short-circuit protection with Type-C instantaneous tripping at 7–10 times rated current and a 6kA rated short-circuit breaking capacity. Its dual-connection arrangement supports lead wire or compatible busbar connection, while the contact-position indicators and mechanically linked handle support clear operation and isolation. Installation must follow the official polarity and wiring diagrams and should be completed by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine CHINT NB1-63DC series DC circuit breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32A rated-current variant officially supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole configuration rated at DC 500V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType-C tripping characteristic, 7–10 × In\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA rated short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e4kV rated impulse withstand voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLead-wire and compatible busbar dual connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail mounting with plug-in structure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 compliance with CE, CB, TÜV, CCC and RoHS listings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC circuit breaker \/ DC MCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current, In\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Voltage, Ue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 500V for 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Short-Circuit Breaking Capacity, Icu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage, Uimp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous Trip Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload and short-circuit protection; switching and isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmospheric Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤95%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIII\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2000m; derating required above 2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLead wire and compatible busbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Conductor Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail mounting, plug-in structure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12kg per pole; calculated 2P nominal total approximately 0.24kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Series-Level Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16W per pole at In ≤63A; exact 32A value Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential and commercial photovoltaic arrays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar DC combiner and distribution boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery energy-storage systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible DC-side inverter circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEV-charging equipment DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTelecommunications DC power networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial DC distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual switching and isolation during authorized maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe system voltage, operating current, prospective fault current, conductor size, polarity and installation conditions must be verified before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCHINT NB1-63DC 32A 2P DC circuit breaker: expected primary item\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted installation instructions: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBusbar or wiring accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType-C thermomagnetic tripping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA fault-current interruption capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked two-pole switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual circuit isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact-position indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity-marked DC wiring arrangement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidual-current protection: not provided; this product is not an RCCB or RCBO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurge protection: not provided; use a separately rated DC SPD where required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially stated by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially listed by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially listed; official certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially listed by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially listed; official certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially stated; declaration\/certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial declaration available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUKCA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty period and product-specific warranty conditions: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":52525354025240,"sku":null,"price":2450.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_12.png?v=1786945442"},{"product_id":"mora-63a-2-pole-1000v-dc-breaker","title":"MORA AES-60H-DC C63 63A 2-Pole 1000V DC Circuit Breaker","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A 2-Pole DC Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC C63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker \/ Solar Protection Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIdentification Basis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel and ratings visible on the supplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMORA AES-60H-DC C63 63A 2-Pole 1000V DC Circuit Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-60H-DC C63 is a two-pole DC circuit breaker marked for 63A and 1000V DC operation. Its compact modular body, linked orange handle and polarity markings make it suitable for professional DC distribution installations where compatibility has been confirmed by a qualified installer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eVerification notice:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The current, pole configuration, voltage, model, IEC 60947-2 marking and Icu value below are visible on the supplied product image. An official model-specific MORA datasheet or manual could not be located; therefore, all other specifications are marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for organized DC distribution boards, the MORA AES-60H-DC C63 combines a compact two-pole format with a mechanically linked orange operating handle. The supplied product image identifies the unit as a 63A model and displays a 1000V DC rating, IEC 60947-2 marking and Icu 10kA marking.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker includes clearly numbered terminal positions, directional\/polarity markings and “Cu Only” conductor markings on the enclosure. These visual indicators support correct identification during professional installation. Because no official model-specific datasheet or installation manual was found, cable size, tightening torque, mounting dimensions, environmental limits and system compatibility must be confirmed before purchase and installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis product should only be selected and installed by a qualified electrician or solar technician according to the actual DC system voltage, prospective fault current, cable specification, polarity and applicable local electrical regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A current marking visible on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked switching design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1000V DC marking visible on the front label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIcu 10kA marking visible on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60947-2 marking displayed on the enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMORA AES-60H-DC series identification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC63 model\/current marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-visibility orange linked operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClearly numbered upper and lower terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirectional and polarity markings printed on the casing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e“Cu Only” conductor marking visible on the terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular form for compatible distribution enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-60H-DC C63\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible product identification; official model page Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible physical configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated DC Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10kA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63 marking present; exact curve verification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial datasheet unavailable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Handle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanically linked orange dual-pole handle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCopper only (“Cu Only” marking)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity \/ Direction Markings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePresent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService Breaking Capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhotovoltaic and solar DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery and energy-storage DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRenewable-energy installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible industrial DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplication note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e These are general applications for this product category. Model-specific suitability was not independently verified from an official MORA datasheet. A qualified installer must confirm voltage, current, fault level, polarity and coordination requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMORA AES-60H-DC C63 breaker unit — visible product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation manual — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarranty documentation — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Feature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOvercurrent \/ overload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified from an official MORA document\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified from an official MORA document\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCircuit isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified from an official MORA document\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity-aware DC installation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirection\/polarity markings visible; official wiring instructions Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIcu 10kA marking visible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product image; certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No official model-specific warranty period or warranty document was located.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52525413007640,"sku":null,"price":1799.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_13.png?v=1786947834"},{"product_id":"tomzn-63a-2-pole-1000v-dc-breaker","title":"TOMZN TOB7Z-63 63A 2-Pole 1000V DC Solar Circuit Breaker","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A 2-Pole 1000V DC Miniature Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker \/ Solar Protection Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A, 2P, 1000V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB7Z-63 63A 2-Pole 1000V DC Solar Circuit Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB7Z-63 is a 63A, two-pole miniature circuit breaker designed for DC circuits up to 1000V. TOMZN lists the series for photovoltaic systems, while the supplied product label identifies a 6kA ultimate breaking capacity and IEC\/EN 60947-2 marking.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB7Z-63 provides compact two-pole circuit protection for compatible high-voltage DC installations. TOMZN’s official product page identifies this model as a 2P, 1000V DC solar miniature circuit breaker and lists 63A among the available current ratings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe regional TOMZN product page states that the breaker is intended for overload and short-circuit protection and may also be used for infrequent operation of the line. Listed application areas include photovoltaic systems and communications DC circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied 63A product image shows a mechanically linked blue operating handle, two green status windows, four screw terminals, polarity markings, Icu 6kA, IEC\/EN 60947-2 and CE markings. Correct DC polarity, circuit voltage, prospective fault current, cable size and protection coordination must be confirmed by a qualified installer before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial TOMZN TOB7Z-63 series product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated-current variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole DC switching configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated for DC systems up to 1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficially listed for photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit protection stated by TOMZN Pakistan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for infrequent line operation according to the regional product page\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIcu 6kA marking visible on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 marking visible on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-visibility blue mechanically linked handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo green contact\/status indicator windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClearly printed polarity and terminal diagram\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB7Z-63\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and product label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC miniature circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial available-current list and product label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated DC Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1000V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied label; regional TOMZN page references the standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload and short-circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN Pakistan product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperational Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfrequent line operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN Pakistan product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo green indicator windows\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Handle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanically linked blue dual-pole handle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity Markings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePresent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService Breaking Capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhotovoltaic and solar DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunications DC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible solar combiner-box circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery and energy-storage DC circuits, subject to engineering verification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRenewable-energy DC installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplication note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Photovoltaic and communications applications are stated by TOMZN. Battery and other system suitability must be confirmed against the installation voltage, continuous current, fault level and applicable regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB7Z-63 63A 2P DC breaker unit — expected primary product; exact retail pack verification unavailable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation manual — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarranty documentation — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection — officially stated by TOMZN Pakistan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection — officially stated by TOMZN Pakistan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole linked disconnection — physical design visible; detailed switching specification Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity identification — printed connection diagram visible on the enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUltimate breaking capacity — Icu 6kA marking visible on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard marking visible; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No official model-specific warranty period or warranty document was located.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52525486276888,"sku":null,"price":1950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_14.png?v=1786948837"},{"product_id":"cnc-63a-2-pole-500v-dc-breaker","title":"CNC YCB8-63PV C63 63A 2-Pole 500V DC Solar MCB","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A 2-Pole 500V DC Photovoltaic Miniature Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV C63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker \/ Solar Protection Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePV heteropolarity \/ polarity-sensitive series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A, 2P, C curve, 500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB8-63PV C63 63A 2-Pole 500V DC Solar MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YCB8-63PV C63 is a 63A, two-pole photovoltaic DC miniature circuit breaker rated for 500V DC. It provides isolation, overload and short-circuit protection with 6kA breaking capacity, thermomagnetic tripping, IP20 protection and IEC\/EN 60947-2 compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEngineered for photovoltaic and other compatible DC distribution systems, the CNC YCB8-63PV combines a compact modular design with comprehensive circuit protection. CNC’s official selection table confirms that the two-pole configuration is rated at 500V DC, while the series supports current ratings up to 63A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe C63 variant uses a C tripping characteristic and thermomagnetic release. Its 6kA ultimate breaking capacity and service breaking capacity equal to 100% of Icu support dependable interruption of DC fault currents when the breaker is correctly selected and installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker supports standard DIN-rail installation and includes polarity markings for correct DC wiring. CNC officially lists isolation, overload and short-circuit protection and identifies photovoltaic, industrial, civil and communication systems among the intended applications. A qualified installer must confirm circuit polarity, voltage, continuous current, prospective fault current, cable sizing and protection coordination before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial CNC Electric YCB8-63PV photovoltaic DC MCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated-current C-curve variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole configuration rated for 500V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIcs equal to 100% of Icu\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIsolation, overload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermomagnetic tripping mechanism\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard DIN-rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWorking temperature range from -35°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2 and EU RoHS requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSource Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV C63\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series data and supplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotovoltaic DC miniature circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePV heteropolarity \/ polarity-sensitive\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial selection table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table and BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial selection table and BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V DC for 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial selection table and BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table and BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService Breaking Capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA \/ 100% of Icu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table and BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63 variant marking; C is an official available curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Curves for Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB, C, K\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermomagnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table and BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified — official sources conflict: 1200V product table vs 500V BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer confirmation required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified — official page contains inconsistent 1,500 and 10,000 operation statements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer confirmation required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupply may enter from top or bottom, subject to correct polarity\/wiring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMoisture Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerating required above 2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLevel 3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Contact Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm Contact Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShunt Release Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial technical table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar photovoltaic DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV string and array protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar combiner boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCivil DC installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication and telecom DC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery and energy-storage circuits, subject to engineering verification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB8-63PV C63 63A 2P breaker unit — primary product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation instructions — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary contacts or other accessories — Not Verified; listed as optional accessories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarranty documentation — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCircuit isolation function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate fault-current interruption capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIcs equal to 100% of Icu\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermomagnetic release\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole linked operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity markings for correct DC connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGreen contact\/status indicator windows\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEU RoHS environmental requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBV \/ LCIE Approval BVPMS_7197\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certificate; valid to 27 March 2028\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN 60947-1:2007+A1:2011+A2:2014\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed on official BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN 60947-2:2017+A1:2020\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed on official BV certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on product; model-specific CE certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A model-specific official warranty period and warranty document were not located.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52525575274776,"sku":null,"price":2199.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_15.png?v=1786950382"},{"product_id":"chint-63a-2-pole-500v-dc-breaker","title":"CHINT NB1-63DC C63A 63A 2-Pole 500V DC Solar Breaker","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A 2-Pole 500V DC Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC C63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e182726\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker \/ Solar Protection Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A, 2P, C curve, 500V DC, 6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCHINT NB1-63DC C63A 63A 2-Pole 500V DC Solar Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CHINT NB1-63DC C63A is a 63A, two-pole DC circuit breaker rated for 500V DC systems. It provides overload and short-circuit protection with C-curve tripping, 6kA breaking capacity, IP20 protection and IEC\/EN 60947-2 compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for photovoltaic, energy-storage and other DC distribution applications, the CHINT NB1-63DC combines dependable circuit protection with a compact DIN-rail format. CHINT's official selection table confirms product code 182726 as the 63A, 2-pole, C-curve variant rated at 500V DC with 6kA breaking capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe breaker includes polarity markings for correct DC wiring, linked two-pole operation, visible contact-status indicators and dual connection support for conductors or busbars. Its operating range of -35°C to +70°C, 20,000-operation mechanical life and altitude rating up to 2,000 metres support demanding solar and industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCorrect polarity, cable sizing, operating current, voltage, prospective fault current and protection coordination must be confirmed by a qualified installer before installation. Refer to the official CHINT manual and wiring diagrams.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial CHINT NB1-63DC series DC circuit breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact C63A, 63A two-pole variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated operating voltage of 500V DC for 2P configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA short-circuit breaking capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-type tripping characteristic, 7–10 × In\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible contact-status indicators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity markings for correct DC connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual conductor and busbar connection capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail mounting with plug-in structure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-2, CE, CB, TÜV, CCC and RoHS listed by CHINT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNB1-63DC C63A 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue and supplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e182726\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC circuit breaker \/ DC MCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current (In)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTripping Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType C, 7–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstantaneous Trip Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIi = 8.5 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExact product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Short-Circuit Breaking Capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService Breaking Capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExact product marking; official catalogue does not list it separately\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot stated in the located official product data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmospheric Relative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 95%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2,000m; derating above 2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIII\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Conductor Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 25mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLead wire and busbar compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail mounting, plug-in structure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 0.24kg for 2P, calculated from 0.12kg per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial catalogue basis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExact 63A value Not Verified; official page states series maximum up to 16W per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer confirmation recommended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial 2D drawing is available, but dimensions were not reproduced without direct confirmation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar photovoltaic arrays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar combiner and DC distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery energy-storage systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC power distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEV charging equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTelecom and communication power networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and industrial DC installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCHINT NB1-63DC C63A 63A 2P breaker unit — verified primary product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted installation manual — Not Verified as an in-box item\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail — Not Verified \/ not listed as included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional accessories — Not Verified \/ not listed as included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA fault-current interruption capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eC-curve tripping response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked two-pole switching operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity markings for correct DC circuit connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact ON\/OFF status indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStored-energy operation and fast closing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT; official certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT; official certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed by CHINT; official declaration available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eREACH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial declaration available for NB1-63DC series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUKCA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial certificate available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A model-specific official warranty duration and warranty policy were not located on the official product page, catalogue or manual listing.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"Default Title","offer_id":52525612138776,"sku":null,"price":2850.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_16.png?v=1786951666"},{"product_id":"mora-2-pole-voltage-current-protector","title":"MORA-2PVA\/80A 2-Pole Adjustable Voltage \u0026 Current Protector","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Voltage \u0026amp; Ampere Protection Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA-2PVA\/80A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage \u0026amp; Current Protection Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonitoring and Protection Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole \/ Line and Neutral\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2PVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Adjustable Current Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMORA-2PVA\/80A 2-Pole Adjustable Voltage \u0026amp; Current Protector\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA-2PVA\/80A is a two-pole adjustable voltage and current protection relay with a digital voltage\/ampere display, Line and Neutral terminals, four setting buttons and an adjustable current marking of 1–80A. Exact manufacturer documentation for this model was not located; technical ranges below are transcribed from the supplied product label and clearly identified as such.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for single-phase AC distribution panels, the MORA-2PVA\/80A combines live voltage and current monitoring with adjustable voltage and ampere protection settings. Its front digital panel displays voltage in red and current in green, while four control buttons provide access to the adjustable parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product image identifies separate Line and Neutral terminals, top IN and bottom OUT connections, and a maximum adjustable-current marking of 80A. The side label also shows over-voltage, under-voltage and timing-setting ranges. Because an exact official manufacturer datasheet or manual could not be located, these label values are not presented as independently verified manufacturer specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation and parameter selection should be completed by a qualified electrician. The installer must verify the supply system, conductor size, load current, protection coordination, enclosure requirements and local electrical regulations before energising the device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMORA-2PVA\/80A adjustable voltage and ampere relay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole Line and Neutral configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital voltage display in red\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital current display in green\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour front control and setting buttons\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate top IN and bottom OUT terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable-current label marking from 1A to 80A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-voltage adjustment marking from 230V to 300V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnder-voltage adjustment marking from 140V to 210V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable timing parameters shown on the side label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular distribution-panel design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE and ISO 9001 markings visible on the product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible product branding; official MORA Pakistan website located\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA-2PVA\/80A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Volt \u0026amp; Ampere Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product construction and terminal markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLine and Neutral\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN and L markings visible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop IN \/ Bottom OUT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible product markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eL\/N Voltage Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–450V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; exact parameter definition Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Current (Io)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–80A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-Voltage Setting (Ov)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 230–300V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnder-Voltage Setting (Ud)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 140–210V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; official datasheet Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIt Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–30 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; exact function Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUt Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–400 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; exact function Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOnt Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–400 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product label; exact function Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital LED, red\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible product feature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital LED, green\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible product feature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Buttons\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible product feature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail style modular housing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisual identification; official mounting specification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThis is a relay\/protection device, not confirmed as an MCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Impulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential single-phase distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial shops and offices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAppliance and equipment supply monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAreas affected by unstable AC voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMain or sub-distribution protection arrangements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInverter or backup AC output circuits, subject to compatibility verification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight industrial control panels, subject to engineering approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMORA-2PVA\/80A two-pole protection device — verified primary item\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail packaging — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted user manual — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail — Not Verified \/ not shown as included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional accessories — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-voltage protection parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable under-voltage protection parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-current protection parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage and current monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable timing parameters shown on the product label\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate Line and Neutral connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible IN and OUT connection guidance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic disconnection\/reconnection behaviour — exact sequence and settings Not Verified without an official manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit interruption capability — Not Verified; upstream MCB\/MCCB protection may still be required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product label; model-specific certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eISO 9001\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on supplied product label; this is a quality-management-system reference, not a product-performance certificate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No model-specific official warranty period or warranty document was located.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52525684949272,"sku":null,"price":2399.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_17.png?v=1786953462"},{"product_id":"tomzn-2-pole-adjustable-voltage-current-protection-relay","title":"TOMZN TOVPD1-60-EC 2-Pole Adjustable Voltage \u0026 Current Protection Relay","description":"\u003ch1\u003e\u003cspan\u003eTOMZN TOVPD1-60-EC 2-Pole Protection Device\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOVPD1-60-EC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable over\/under-voltage and over-current protection relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Device \/ Monitoring Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pole, single-phase Line + Neutral\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOVPD1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower system\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 VAC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant: This product is a voltage\/current monitoring protection relay. The official manufacturer page does not specify a short-circuit breaking capacity or earth-leakage function. It should not be presented as a replacement for a correctly rated MCB, fuse, RCCB or RCBO.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOVPD1-60-EC 2-Pole Adjustable Voltage \u0026amp; Current Protection Relay\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOVPD1-60-EC is a 230 VAC DIN-rail protection relay that monitors supply voltage and load current in real time. It provides adjustable over-voltage, under-voltage and over-current protection, automatic recovery, dual digital V\/A displays and configurable protection and recovery delays.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eProtect sensitive AC loads from unstable supply conditions with the TOMZN TOVPD1-60-EC. Designed for single-phase 230 VAC installations, this compact two-pole protection device continuously displays voltage and current while monitoring the circuit against excessive voltage, low voltage and over-current conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen a configured limit is exceeded, the device disconnects the load according to the selected action time. Once the supply returns to the configured recovery range, automatic recovery reconnects the circuit after the programmed delay. Adjustable thresholds and timing parameters help installers adapt the device to residential, light-commercial and solar AC distribution applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe front panel combines separate voltage and current displays, condition indicators and four setting buttons. Its compact 35 mm DIN-rail format supports neat installation inside compatible distribution enclosures. Installation and parameter selection should be completed by a qualified electrician, with suitable upstream short-circuit and residual-current protection selected for the circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable under-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic recovery after supply conditions return to the configured range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate digital voltage and current displays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigurable protection action time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigurable recovery delay time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable power-on delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage calibration function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFactory reset and stored fault inquiry functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFront-panel status LEDs and setting buttons\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 35 mm DIN-rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOVPD1-60-EC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable over\/under-voltage and over-current protective relay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pole Line + Neutral\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified from product configuration\/image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer marketing current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified on official product title\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum\/current-setting variants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial page lists 1–40 A and 1–63 A adjustable variants; exact supplied variant rating is not printed on the provided front image\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for supplied unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage protection threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230–300 V or OFF; default 270 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage recovery threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e225–295 V; default 250 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage action time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–30 s; default 0.5 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage recovery delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–500 s; default 30 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnder-voltage protection threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140–210 V or OFF; default 170 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnder-voltage recovery threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e145–215 V; default 190 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnder-voltage action time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–30 s; default 0.5 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnder-voltage recovery delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–500 s; default 30 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-current adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–40 A variant: default 20 A; 1–63 A variant: default 40 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-current action time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–30 s; default 0.5 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-current recovery delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–500 s; default 30 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower-on delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–500 s; default 10 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately ±10% adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent-limit fault count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–20 times; default OFF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating\/mechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeparate voltage and current digital displays\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEarth-leakage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential single-phase distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight-commercial AC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection of appliances and selected branch circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar inverter AC output\/load-side distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackup power and UPS load circuits operating at 230 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAreas with unstable mains voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl panels requiring adjustable voltage and current supervision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis device is for AC monitoring\/protection. It is not specified for DC PV string use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe official manufacturer page does not publish a complete pack-list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOVPD1-60-EC protection device: product unit shown; exact boxed quantity Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted user manual: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-voltage disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnder-voltage disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-current disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic recovery\/reconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable protection action timing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable recovery delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable power-on delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStored fault inquiry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigurable current-limit fault count\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit interruption, surge suppression, arc-fault protection and residual-current\/earth-leakage protection are not stated on the official product page and must not be assumed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE marking is visible on the product front.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate CE certificate: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN compliance standard: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTÜV\/UL certification: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial manufacturer warranty duration: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52525777322264,"sku":null,"price":2450.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_18.png?v=1786954867"},{"product_id":"cnc-2-pole-adjustable-voltage-current-protection-relay","title":"CNC Electric YC6VA 2-Pole Adjustable Voltage \u0026 Current Protection Relay","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIdentified series\/model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYC6VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage and current protection relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable over\/under-voltage and over-current protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pole, single-phase Line + Neutral\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable rated-current variants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 A or 63 A, subject to product label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact supplied-unit current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified — rating is not visible in the supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant: YC6VA is a voltage\/current monitoring protection relay. The official documents specify a 1NO relay output but do not give it the short-circuit interrupting function of an MCB or the earth-leakage function of an RCCB\/RCBO. Use suitable upstream protection selected by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC Electric YC6VA 2-Pole Adjustable Voltage \u0026amp; Current Protection Relay\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YC6VA is a microprocessor-based protection relay for single-phase AC networks. It monitors and displays voltage and current, provides adjustable over-voltage, under-voltage and over-current protection, and automatically reconnects the load after normal supply conditions return.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YC6VA combines real-time voltage and current monitoring with adjustable protection in a compact two-module DIN-rail enclosure. Designed for single-phase AC distribution, it analyses the incoming supply and disconnects the load through an electromagnetic relay when voltage or current exceeds the programmed limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsers can configure over-voltage, under-voltage, over-current, trip timing, recovery delay and power-on delay settings from the front controls. The dual digital display provides clear voltage and current readings, while dedicated status indicators show over-voltage, under-voltage, over-current and power conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter the fault clears, automatic recovery restores the output following the selected delay. Settings are retained in non-volatile memory. The YC6VA is suitable for residential, commercial and industrial single-phase distribution systems, including the AC side of compatible solar and backup-power installations. Installation and parameter selection should be performed by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable under-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic recovery and reconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate digital voltage and current displays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable voltage\/current protection action time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable recovery and power-on delays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous over-current event-count setting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-volatile parameter memory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFront status LEDs and four setting buttons\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1NO electromagnetic relay output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 35 mm DIN-rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\/model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYC6VA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified by official product design and series documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage and current protector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-phase AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePole arrangement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLine + Neutral, 2-pole terminal arrangement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified from product configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated supply voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 220 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating-voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 80–400 V, single phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated-current variants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 A or 63 A, subject to product label\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact supplied-unit rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot visible on supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-current setting range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–40 A or 1–63 A, depending on variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage setting range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230–300 V; manufacturer notes customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnder-voltage setting range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–220 V; manufacturer notes customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage protection action time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–30 s; factory setting 1 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-current action time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–30 s; factory setting 1 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecovery delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–600 s; factory setting 5 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower-on delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–300 s\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous over-current protection count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA01–A20 or OFF; factory setting OFF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage measurement accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2% of full range maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput contact\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1NO\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1.5 W on official product page\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,000,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2,000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤50% at 40°C, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 36 × 85 × 64 mm from official drawing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial web page and manual present inconsistent ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial web page and manual present inconsistent ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal wire size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\/WiFi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified for YC6VA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eCurrent Variant Reference\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVariant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRated operating current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum current within 10 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum load power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eYC6VA 40 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eYC6VA 63 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.9 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eConfirm the rating printed on the actual supplied product before publishing a current-specific listing or selecting cable and upstream protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential single-phase distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and administrative buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial single-phase control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAppliance and branch-circuit voltage supervision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar inverter AC output\/load-side distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUPS and backup-power AC circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocations affected by mains over-voltage or under-voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCircuits requiring adjustable over-current supervision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe YC6VA is an AC protection relay and is not specified for DC PV strings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe official manufacturer page and manual do not provide a complete retail pack-list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCNC Electric YC6VA protection relay: product unit shown; boxed quantity Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted instruction manual: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-voltage disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnder-voltage disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-current disconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic recovery\/reconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable voltage protection action time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable over-current action time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable recovery delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable power-on delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelectable continuous over-current event count\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit interruption, surge suppression, residual-current\/earth-leakage protection and arc-fault protection are not specified for this model and must not be assumed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE \/ Low Voltage Directive 2014\/35\/EU Attestation of Conformity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCertificate model coverage includes YC6VA-40, YC6VA-63 and YC6VA-80\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCertificate referenced standard: EN 60898-1:2019+A1:2024\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial YC6VA manual states product standard EN 60947-5-1:2004\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL\/TÜV product certification: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC's official policy states \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24 months from the date of manufacture for other low-voltage apparatus\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The manufacturer notes that the warranty period may change according to the signed customer contract. Local seller\/importer terms should be confirmed before publication.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52525866680600,"sku":null,"price":2650.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_19.png?v=1786956368"},{"product_id":"tomzn-63a-2-pole-changeover","title":"TOMZN TO219G 63A 2-Pole Manual Changeover Switch – 400V AC I–0–II Dual Power Transfer","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified result\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTO219G Blue 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact product type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-power manual transfer \/ changeover isolating switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Protection \u0026amp; Switching Accessories \u0026gt; Manual Changeover Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual; not an automatic transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTO219G series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant: This product is a manual changeover\/isolating switch. It is not verified as an MCB, fuse, RCBO, surge protector or automatic transfer switch, and it should not be presented as providing overcurrent or short-circuit protection. Use correctly rated upstream protective devices and installation by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TO219G 63A 2-Pole Manual Changeover Switch – 400V AC I–0–II Dual Power Transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TO219G is a 63A, 2-pole manual changeover switch for controlled selection between two AC power sources. Its linked I–0–II handle provides Source I, centre-off isolation and Source II positions for manual utility, generator, inverter or PV-source transfer applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eManage two independent AC supplies through one compact manual switching device with the TOMZN TO219G. Rated at 63A and 400V AC, the 2-pole changeover switch uses a mechanically linked blue handle to select Source I, disconnect both source paths in the centre 0 position, or select Source II.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN's official product information describes the TO219G as a dual-power manual transfer switch for power-source changeover. The official connection description confirms that position I connects terminals 1–2 and 5–6, position II connects terminals 1–4 and 5–8, and the centre position disconnects both groups. This makes it suitable for professionally designed mains\/generator, mains\/inverter and other two-source AC systems where manual control is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe TO219G is a switching and isolation device—not an automatic transfer system and not a substitute for circuit protection. Selection, cable sizing, enclosure, protective devices and installation must be completed by a qualified electrician in accordance with the applicable electrical code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact TOMZN TO219G Blue model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2-pole linked switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC rated voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz rated frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual three-position I–0–II operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre-off position disconnects both contact groups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual selection between two independent AC sources\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-22A utilization category printed on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUi 690V rated insulation voltage printed on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-3 and GB\/T 14048.3 markings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular form for electrical distribution applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTO219G Blue 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual transfer \/ changeover isolating switch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial function description \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUtilization category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC-22A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional standard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 14048.3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePosition I contact state\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–2 connected; 5–6 connected\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePosition II contact state\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–4 connected; 5–8 connected\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCentre position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBoth groups disconnected\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated operational voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated impulse withstand voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConditional short-circuit current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot applicable as a verified breaker rating \/ Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing material \/ flame rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual utility-to-generator source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual utility-to-inverter source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar\/PV-supported AC power systems with an appropriate upstream design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential backup-power distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial backup-power distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEssential-load source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical control and distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems requiring a centre-off isolation position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TO219G 63A 2-pole manual changeover switch: Not Verified as official package content\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation instructions: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection and Functional Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked 2-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree-position manual selection: I–0–II\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre-off disconnection of both contact groups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual isolation between two selected source paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact state for each position documented by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eNot verified as included: overload protection, short-circuit protection, residual-current\/leakage protection, surge protection, under\/over-voltage protection, automatic source sensing or automatic transfer. Appropriate upstream protection is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-3 marking: visible on product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGB\/T 14048.3 marking: visible on product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE mark: visible on product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThird-party certificate numbers or downloadable conformity certificates: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial manufacturer warranty term for this exact model: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52534176907544,"sku":null,"price":1499.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_20_f218227f-05f2-4b35-a749-6cdc040f3270.png?v=1787036800"},{"product_id":"tomzn-80a-2-pole-changeover","title":"TOMZN TO219G 80A 2-Pole Manual Changeover Switch – 400V AC I–0–II Dual Power Transfer","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified result\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTO219G 2P 80A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact product type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-power manual transfer \/ changeover isolating switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Switching Accessories \u0026gt; Manual Changeover Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual; not an automatic transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTO219G series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant: Although the manufacturer page uses “circuit breaker” wording in its product title\/category, no overload or short-circuit breaking specification was found for this exact 80A model. It should be presented primarily as a manual transfer\/changeover isolating switch, not as a substitute for an MCB, MCCB, fuse, RCBO or automatic transfer switch. Correct upstream protection and professional installation are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TO219G 80A 2-Pole Manual Changeover Switch – 400V AC I–0–II Dual Power Transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TO219G is an 80A, 2-pole manual changeover switch designed for controlled selection between two AC power sources. Its I–0–II mechanism provides Source I, centre-off isolation and Source II positions for utility, generator, inverter and backup-power applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TO219G 80A manual changeover switch offers a straightforward way to select between two independent AC supplies within a professionally designed electrical system. The 2-pole device is rated at 400V AC and uses two adjacent blue operating handles with three selectable states: Source I, centre 0 and Source II.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN's official product information confirms the TO219G 2P 80A model and documents its contact states. In position I, terminals 1–2 and 5–6 are connected. In position II, terminals 1–4 and 5–8 are connected. In the middle position, both contact groups are disconnected. This centre-off arrangement supports deliberate manual isolation before selection of the alternate source.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe product is suitable for professionally engineered mains\/generator, mains\/inverter and other two-source AC arrangements. It does not provide automatic source detection or automatic transfer. Cable sizing, protection, enclosure selection, earthing and installation must be completed by a qualified electrician according to the applicable electrical code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact TOMZN TO219G 80A model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e80A rated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2-pole manual source switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz frequency marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree-position I–0–II operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre-off position disconnects both contact groups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual selection between two independent AC sources\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo adjacent ribbed blue operating handles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-22A utilization category printed on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUi 690V rated insulation voltage printed on the product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-3 and GB\/T 14048.3 markings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTO219G 2P 80A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual transfer \/ changeover isolating switch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial function description \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUtilization category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC-22A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional standard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGB\/T 14048.3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePosition I contact state\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–2 connected; 5–6 connected\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePosition II contact state\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–4 connected; 5–8 connected\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCentre position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBoth groups disconnected\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic transfer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo; manual operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial product type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated operational voltage (Ue)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated impulse withstand voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConditional short-circuit current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal conductor capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing material \/ flame rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual utility-to-generator changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual utility-to-inverter changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar\/PV-supported AC systems with appropriate system design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential backup-power distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial backup-power distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEssential-load source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical distribution and control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems requiring a centre-off isolation position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TO219G 80A 2-pole manual changeover switch: Not Verified as official package content\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation instructions: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection and Functional Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole manual switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree selectable positions: I–0–II\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre position disconnects both contact groups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual isolation between two selected source paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact states for both source positions documented by TOMZN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eNot verified as included: overload protection, short-circuit protection, residual-current\/leakage protection, surge protection, under\/over-voltage protection, automatic source sensing or automatic transfer. Use appropriately rated upstream protective devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-3 marking: visible on product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGB\/T 14048.3 marking: visible on product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE mark: visible on product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDownloadable conformity certificate or certificate number: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial manufacturer warranty term for this exact model: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52534405267736,"sku":null,"price":1950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_21.png?v=1787038208"},{"product_id":"cnc-63a-2-pole-changeover","title":"CNC Electric YCBZ 63A 2-Pole Manual Changeover Switch – 230\/400V AC I–0–II","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified result\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCBZ \/ official YCBZ-125 series page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual changeover switch \/ switch-disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Voltage \u0026gt; Final Distribution \u0026gt; Change-Over Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II \/ 1–0–2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual; not an automatic transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eImportant: This product is a manual changeover switch used as a switch-disconnector under normal circuit conditions. The official YCBZ page does not list overload, short-circuit, residual-current or surge protection for this device. Correct upstream circuit protection and installation by a qualified electrician are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC Electric YCBZ 63A 2-Pole Manual Changeover Switch – 230\/400V AC I–0–II\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC Electric YCBZ 63A 2-pole manual changeover switch provides deliberate I–0–II selection between two AC power sources. The supplied unit is marked 230\/400V AC, 50\/60Hz and AC-22A, with a linked red operating handle and eight numbered terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for controlled manual source selection, the CNC Electric YCBZ 63A changeover switch allows a connected load circuit to be switched between two independent AC supplies. Its three-position I–0–II mechanism provides Source I, centre-off isolation and Source II selection through a linked red two-pole operating handle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCNC Electric's official YCBZ product page classifies the series as a changeover switch used as a switch-disconnector and states compliance with IEC 60947-3. The official series supports 63A, 80A, 100A and 125A ratings, 1P to 4P configurations, 50\/60Hz operation and 1–0–2 contact form. The attached 63A 2P unit is marked 230\/400V AC and AC-22A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe switch is appropriate for professionally designed utility\/generator, utility\/inverter and other dual-source AC systems requiring manual transfer. It does not automatically detect source failure or transfer the load. Enclosure selection, upstream protection, cable sizing, earthing and installation must follow the applicable electrical code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine CNC Electric YCBZ series design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated-current variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2-pole manual source switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree-position I–0–II \/ 1–0–2 operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e230\/400V AC marking on the supplied product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC-22A utilization-category marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked red two-pole operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEight numbered terminal positions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-3 product marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 series protection degree\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e35mm DIN-rail mounting with fast clip\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCBZ; official page titled YCBZ-125\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A, 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series options \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChangeover switch used as switch-disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series option \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series option \/ supplied product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct-marked voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\/400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial series rated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240\/415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page \/ product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact form\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–0–2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHandle positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI–0–II\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUtilization category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC-22A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct standard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,500 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5°C to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal \/ cable size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 60715 35mm DIN rail, fast clip\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage (Ui)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this exact 63A variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated impulse withstand voltage (Uimp)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit breaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified \/ not listed as a protective-breaker rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified from accessible text\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing material \/ flame rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eVoltage Marking Note\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product is marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230\/400V AC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while CNC Electric's current official YCBZ-125 series page lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e240\/415V AC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This may represent a label or market-version difference. Confirm the nameplate on delivered stock before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual utility-to-generator changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual utility-to-inverter changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential backup-power systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial backup-power distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-supported AC systems with appropriate engineering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEssential-load source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistribution boards and control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems requiring centre-off source isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCNC Electric YCBZ 63A 2-pole changeover switch: Not Verified as official package content\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser \/ installation manual: Not Verified as included in the retail box\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection and Functional Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual two-source selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinked two-pole operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentre-off position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitch-disconnector function under normal conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eNot verified as included: overload protection, short-circuit protection, residual-current\/leakage protection, surge protection, voltage protection, automatic source detection or automatic transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60947-3: stated by CNC Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-3 marking: visible on supplied product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE mark: visible on supplied product\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCertificate number \/ downloadable conformity certificate for this exact variant: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty period specifically assigned to this exact YCBZ 63A 2P variant: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52534523887896,"sku":null,"price":1950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_22_fe278bb0-2d0b-404b-b5b8-0484ffdbb724.png?v=1787040391"},{"product_id":"mora-63a-2-pole-changeover","title":"MORA AES-988 63A 2-Pole Manual Changeover Switch – 400V AC","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Result\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-988\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual changeover \/ transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Protection \u0026amp; Switching Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-988 series; generation Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC dual-source manual switching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrimary Evidence\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product nameplate and terminal diagram\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eResearch note: MORA's official Pakistan website was located, but an official product page, datasheet or manual for this exact AES-988 63A 2-pole variant could not be located. Only details visible on the supplied product have therefore been treated as verified. All other fields are marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMORA AES-988 63A 2-Pole Manual Changeover Switch – 400V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-988 is a 63A, 2-pole manual changeover switch designed for controlled selection between two compatible AC power sources. Its mechanically linked orange handle operates both poles together, while the printed terminal diagram supports correct identification during professional installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe MORA AES-988 63A 2-Pole Manual Changeover Switch provides a compact method of manually selecting between two compatible AC supplies in a properly engineered electrical or backup-power system. The product nameplate identifies a 63A current rating, 400V AC rating and 50Hz frequency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts two switching poles are mechanically linked through a single operating handle, enabling coordinated source selection. Clearly numbered terminals and a front-mounted connection diagram assist the installer when planning the circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe device may be suitable for selected mains, generator, inverter or solar-backup changeover arrangements. Final source compatibility, conductor sizing, upstream protection, earthing, neutral treatment and enclosure requirements must be confirmed by a qualified electrician. This product must not be marketed as an automatic transfer switch, circuit breaker, RCCB, surge protector or uninterrupted power supply unless separate official documentation confirms those functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rated current shown on the product nameplate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-pole mechanically linked switching arrangement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual selection between Source I and Source II\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e400V AC rated voltage shown on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50Hz operating frequency shown on the supplied unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProminent orange linked operating handle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFront-printed switching and terminal diagram\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUpper terminals numbered 1 and 5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLower terminals numbered 2, 4, 6 and 8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular electrical-panel form factor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for professionally designed dual-source AC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMORA Electric AES-988 product identification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMORA Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAES-988\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual changeover \/ transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitching Sources\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSource I \/ Source II\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCentre-OFF Position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpper Terminal Markings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1, 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLower Terminal Markings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2, 4, 6, 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUtilization Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Insulation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpulse Withstand Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual selection between two compatible AC supplies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUtility and generator changeover systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUtility and inverter backup arrangements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelected solar-backup distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShops, offices and small commercial systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintenance or source-isolation arrangements designed by a qualified electrician\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × MORA AES-988 63A 2-Pole changeover switch — visible product only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation manual — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProduct packaging — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eVerified switching characteristics:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanically linked operation of two poles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual separation and selection of two source paths according to the printed terminal diagram\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe following protection functions are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and must not be claimed:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEarth-leakage \/ residual-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurge protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver-voltage or under-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic source monitoring or automatic transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eArc-fault protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eSeparate appropriately rated protective devices may be required by the installation design.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNo certification mark or official certificate for this exact variant could be verified from the supplied front image or an official MORA document.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC \/ EN standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty for the MORA AES-988 63A 2-pole variant: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"MORA","offers":[{"title":"Default Title","offer_id":52534655418648,"sku":null,"price":1499.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_e44bbd5f-f897-43b0-9b0a-05e0b47a43ea.png?v=1787041496"},{"product_id":"tomzn-fire-extinguishing-device","title":"TOMZN TOFS-QRR0.01G\/S DIN-Rail Aerosol Fire-Extinguishing Device","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Result\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOFS-QRR0.01G\/S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAerosol fire-extinguishing device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFire Protection Accessory \/ Electrical Panel Safety\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended Installation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistribution boxes and compatible enclosed electrical equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory; not an inverter, battery or circuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOFS series; generation Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOFS-QRR0.01G\/S DIN-Rail Aerosol Fire-Extinguishing Device\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOFS-QRR0.01G\/S is a compact DIN-rail aerosol fire-extinguishing device intended for compatible electrical distribution boxes and enclosed equipment. The manufacturer listing specifies protection for an enclosure volume up to 0.1m³, spray release within 6 seconds and a stated 10-year service life.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOFS-QRR0.01G\/S is designed as a compact fire-suppression accessory for installation inside a compatible electrical distribution box or similarly enclosed electrical space. Its DIN-rail format allows it to be incorporated into a professionally designed panel without requiring a conventional pressurized cylinder.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's published product listing, the device produces a dense fire-extinguishing aerosol following electrical or thermal initiation. The listing specifies a protected enclosure volume of up to 0.1m³, a spray-release time of no more than 6 seconds and an application temperature range from −50°C to +90°C. A 10-year expiration\/service-life period is also stated by the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe device must be selected and installed according to the exact enclosure volume, hazard type, clearances, initiation method and applicable fire\/electrical regulations. It should be treated as a supplementary enclosure-protection product—not as a substitute for required fire alarms, portable extinguishers, building suppression systems, protective circuit devices or professional fire-risk assessment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact aerosol fire-extinguishing device for enclosed electrical equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer model TOFS-QRR0.01G\/S\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail installation format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended for compatible distribution boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed protected space up to 0.1m³\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed spray-release time of 6 seconds or less\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed environmental range from −50°C to +90°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-stated 10-year expiration\/service-life period\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for electrical or thermal initiation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact red molded enclosure with external initiation cord\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer lists electronic and solar-photovoltaic usage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo conventional pressure cylinder indicated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZhejiang Tongzheng Electric Co., Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOFS-QRR0.01G\/S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAerosol fire extinguisher \/ suppression device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible distribution box or enclosed electrical equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtected Space\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1m³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpray Release Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤6 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Environmental Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−50°C to +90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInitiation Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical or thermal initiation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStated Expiration \/ Service Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 years\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStrontium Nitrate Content\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50%–58%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAgent Mass\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25g marking visible in supplied marketing image; exact definition Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCord Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10cm marking visible in supplied marketing image; exact definition Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e170° Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisible in supplied marketing image; exact meaning and unit Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtected Fire Classes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActivation Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage \/ Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry \/ Region of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZhejiang, China\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible electrical distribution boxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnclosed switchgear and control compartments within the stated volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar photovoltaic electrical enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall electrical cabinets requiring professionally designed supplementary aerosol suppression\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential, commercial or industrial panels only where the device is suitable for the specific hazard and local regulations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eVisible in the supplied product image:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × TOMZN aerosol fire-extinguishing device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × TOMZN retail carton\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe following are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail or mounting accessories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional initiation components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCertificates or inspection documentation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocal aerosol discharge inside a compatible enclosed space\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical or thermal initiation stated by the manufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAerosol mechanism described by the manufacturer as cooling and chemically inhibiting combustion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCoverage limited to a manufacturer-listed space of up to 0.1m³\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eImportant limitations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-class suitability is Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eActivation temperature is Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThis device does not replace an MCB, MCCB, RCCB\/RCD, surge protector or arc-fault protective device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThis device does not replace code-required alarms, portable extinguishers or a certified building fire-suppression system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitability for lithium-ion battery fires is Not Verified for this exact model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial certificates for this exact model were not located.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark appears on some product imagery; official certificate Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN \/ IEC fire standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ FM approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLocal Pakistan approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOfficial warranty period and terms for this exact model: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's stated 10-year expiration\/service-life period is not the same as a 10-year product warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52535819272472,"sku":null,"price":1899.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_1_0c3f2568-872f-48dc-80df-55e232571b6d.png?v=1787042816"},{"product_id":"solar-panel-water-drain-clip-for-35mm-frame","title":"Solar Panel Water Drain Clip for 35mm Frame","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact product\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Panel Water Drain Clip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKingwooh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSUS 304\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories \u0026gt; PV Panel Drainage Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar system \/ solar panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation site\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar panel frame\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSuitable specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eIdentification is based on the supplied images and the matching manufacturer-hosted product listing. The listing is a supplier storefront rather than a standalone technical datasheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eKingwooh SUS 304 Stainless Steel Solar Panel Water Drain Clip for 35mm Frame\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Kingwooh SUS 304 solar panel water drain clip is a compact stainless-steel accessory designed for compatible 35 mm photovoltaic module frames. Its shaped channel guides water away from the lower edge of the panel frame, while the silver stamped-metal construction provides a neat, low-profile installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eKeep compatible photovoltaic module frames better prepared for water run-off with the Kingwooh SUS 304 Solar Panel Water Drain Clip. Designed for a 35 mm suitable specification, this silver stainless-steel accessory attaches at the solar-panel frame edge and uses a formed central channel with a lower drainage lip to guide water away from the frame.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied dimensional image shows a compact 53 mm overall width and 37.5 mm overall height. Its stamped-metal profile includes two panel-frame hooks, a 30 mm inner vertical section and a 16 mm lower projection. The clip is intended as a passive mechanical accessory and contains no electrical or powered components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering or installation, confirm that the solar module frame profile, lip geometry and drainage arrangement match the clip. Do not allow the accessory to contact or damage the module glass, backsheet, seals, cables or existing drainage openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKingwooh solar-panel drainage accessory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed model\/designation: SUS 304.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStainless-steel construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSilver finish.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable specification: 35 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for installation on a solar-panel frame.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e53 mm overall width shown in the supplied dimensional image.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e37.5 mm overall height shown in the supplied dimensional image.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFormed central water-guide channel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual upper panel-frame hooks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact lower drainage lip.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePassive mechanical design with no electrical connection required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKingwooh\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Panel Water Drain Clip\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSUS 304\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless steel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilver\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSuitable specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar system\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation site\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar panel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e53 mm \/ 2.09 in\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied dimensional image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall height\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37.5 mm \/ 1.48 in\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied dimensional image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInner vertical height\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mm \/ 1.18 in\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied dimensional image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTop depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm \/ 0.39 in\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied dimensional image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLower projection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 mm \/ 0.62 in\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied dimensional image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLower water-guide tab width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm \/ 0.39 in\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied dimensional image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensional tolerance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible frame-profile geometry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChina\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-hosted product listing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential rooftop photovoltaic arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial rooftop photovoltaic arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGround-mounted solar arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible framed PV modules with a 35 mm suitable specification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-panel frame-edge water guidance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility must be confirmed against the exact module-frame profile before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar panel water drain clip(s): quantity Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation hardware: Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted instructions: Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied image showing multiple clips does not verify the retail pack quantity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis is a passive drainage accessory, not an electrical protection device. No overcurrent, overvoltage, surge, isolation, ingress-protection or other electrical protection rating is applicable or verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/p\u003e","brand":"EX Solar","offers":[{"title":"Default Title","offer_id":52535862067480,"sku":null,"price":149.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_2_b8890854-3d4b-4a96-8d6f-0c0ae1bd7ab9.png?v=1787043865"},{"product_id":"tomzn-mts-changeover-63a","title":"TOMZN TOB1-63H MTS 2P+2P 63A Dual-Power Manual Changeover Breaker","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Information\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Dual-Power Manual Transfer Switch with MCBs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H MTS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A \/ C63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P + 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Protection \u0026gt; Manual Transfer \/ Changeover Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual changeover breaker assembly \/ accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual; not an automatic transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H family; generation Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product image matches TOMZN's official 2P+2P TOB1-63H MTS product family. It combines two 2-pole C-curve miniature circuit-breaker sections with a central manual mechanical transfer mechanism.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB1-63H MTS 2P+2P 63A Dual-Power Manual Changeover Breaker\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB1-63H MTS 2P+2P 63A is a manual dual-power changeover assembly designed to select between two AC supply sources. It combines two 2-pole C63 MCB sections with a central mechanical interlock, 50\/60Hz operation and a manufacturer-listed 6kA breaking capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TOMZN TOB1-63H MTS 2P+2P 63A provides a manually operated method of changing a load between a normal AC source and a reserve supply such as a generator. The assembly shown uses two 2-pole TOB1-63H C63 miniature circuit breakers connected through a central mechanical MTS selector, helping prevent simultaneous manual engagement of both source sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN lists the TOB1-63H MTS family for two-path AC power systems operating at 50\/60Hz, with a rated working-voltage range of 240–400V and available current ratings including 63A. The supplied 63A unit is face-marked 400V~, C63 and 6000A. The MCB sections carry IEC 60898-1 markings, while the central transfer mechanism is marked IEC\/EN 60947-6-1.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is a manual transfer device, not an ATS. Source changeover requires deliberate physical operation. Correct system design, source isolation, conductor sizing, protective coordination and installation must be completed by a qualified electrician in accordance with applicable local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB1-63H MTS product family.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2P + 2P dual-source configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A \/ C63 supplied variant.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual normal-to-reserve source selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo linked 2-pole MCB handle groups.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentral mechanical MTS interlock mechanism.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed 240–400V AC working-voltage range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50\/60Hz operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed 6kA breaking capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail form factor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload and short-circuit protection through the TOB1-63H MCB sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible IEC 60898-1 and IEC\/EN 60947-6-1 standard markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOMZN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking and official manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel \/ family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTOB1-63H MTS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct marking and official manufacturer page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P + 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page and supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUser-specified variant and C63 product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC63 product marking; official TOB1-63H MCB page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated working-voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240–400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial TOMZN MTS page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnit face marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V~\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial TOMZN MTS page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaking capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA \/ 6000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial TOMZN MTS page and product marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransfer method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual mechanical selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturer page and supplied image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of source MCB sections\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles per source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial 2P+2P page and supplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting format\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct design; rail size Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMCB standard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60898-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransfer-device standard marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-6-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupplied product image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure \/ IP rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal conductor capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical endurance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eVoltage Verification Note\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe official 2P+2P MTS page describes a 240–400V AC family range and also contains a separate “230V” line. The supplied 63A unit itself is marked 400V~. Confirm the voltage requirement and exact SKU with TOMZN or the authorized supplier before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUtility-to-generator manual changeover systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormal-source to reserve-source selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential backup-power distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial backup-power panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall industrial or agricultural AC distribution systems where a 63A 2P+2P manual transfer arrangement is appropriate.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems requiring manual rather than automatic source transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFinal suitability depends on system voltage, fault level, earthing arrangement, neutral-switching requirements and local electrical code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTOMZN TOB1-63H MTS 2P+2P 63A assembled changeover device: Not Verified as official retail box content.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation instructions: Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail or mounting hardware: Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection through the TOB1-63H MCB sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection through the TOB1-63H MCB sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanical manual source interlocking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnder-voltage and phase-loss protection are stated on TOMZN's MTS product page, but the implementation and applicability to this exact 2P+2P 63A unit are Not Verified by a model-specific datasheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis product does not provide verified surge protection, residual-current protection, arc-fault protection or automatic transfer control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE marking is visible on the supplied unit; an official declaration or certificate was not found.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60898-1 marking is visible on the MCB sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC\/EN 60947-6-1 marking is visible on the central MTS mechanism.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGB\/T 10963.1 marking is visible on the MCB sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/p\u003e","brand":"TOMZN","offers":[{"title":"Default Title","offer_id":52536024432920,"sku":null,"price":2799.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_3_3ce7d76b-df5c-4991-bcb5-f9bc93770a9f.png?v=1787045353"},{"product_id":"cnc-mts-changeover-63a","title":"CNC YCB8-63PV DC MTS 2P+2P 63A Manual Changeover","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual DC transfer\/changeover assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P + 2P (two mechanically interlocked 2-pole source breakers)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaker series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterlock marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYC88-00M (visible on supplied product image)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A (visible on both YCB8-63PV breakers)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories → DC Protection → Manual Transfer Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ DC protection and manual source-selection device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual; not an automatic transfer switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eImportant: CNC's official YCB8-63PV data verifies the electrical specifications of each 2-pole breaker component. A separate official CNC page or complete datasheet for this exact YC88-00M 2P+2P assembled MTS was not located. Assembly-level claims not confirmed by CNC are marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCNC YCB8-63PV DC MTS 2P+2P 63A Manual Changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CNC DC MTS combines two 63A YCB8-63PV 2-pole photovoltaic DC miniature circuit breakers with a central manual interlock for selecting between two compatible DC sources. Each official 2P YCB8-63PV breaker is rated for DC500V when correctly wired in series and provides overload, short-circuit and isolation protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for controlled manual selection between two compatible DC feeds, this CNC 2P+2P changeover assembly uses two polarity-marked YCB8-63PV breakers and a mechanical interlock to prevent both source handles from being closed together during normal operation. The black and red linked handles provide clear source differentiation, while the modular DIN-rail format is suitable for properly engineered photovoltaic and other DC distribution systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCNC officially specifies the YCB8-63PV series for photovoltaic and other DC applications, with thermomagnetic operation, a breaking capacity of 6kA and protection against overload and short circuit. For the 2-pole configuration, the rated working voltage is DC500V when the poles are connected in the approved series arrangement. Installation must follow the official polarity and wiring diagram.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is a manual changeover device, not an ATS. It must not be used to parallel two sources, and it must not be switched under load unless the complete assembly and installation have been approved for that duty by a qualified electrical engineer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo-source manual DC changeover configuration with 2P + 2P breakers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e63A rating marked on both CNC YCB8-63PV breaker sections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC500V rated working voltage for each official 2-pole YCB8-63PV breaker when wired correctly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentral mechanical interlock assists in preventing simultaneous source closure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6kA ultimate breaking capacity for the official YCB8-63PV breaker component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermomagnetic trip mechanism\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload, short-circuit and isolation protection through the YCB8-63PV breakers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity-marked DC terminals for correct series wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard DIN35 rail mounting for the breaker component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 protection degree for the YCB8-63PV component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2.5–25mm² terminal wiring capacity and 3.5N·m terminal torque for YCB8-63PV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for properly engineered photovoltaic and other compatible DC distribution systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification scope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaker model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct image + official CNC source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterlock model\/marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYC88-00M\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct image only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual DC changeover \/ transfer assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSource configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P + 2P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct image; supported by official YCB8-63PV range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated working voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC500V per 2P YCB8-63PV breaker when correctly wired in series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial CNC source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum series voltage of YCB8-63PV family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to DC1000V with 4 poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial CNC source; not the rating of this 2P+2P assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated insulation voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC1200V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated impulse withstand voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate breaking capacity (Icu)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6kA at T=4ms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eService breaking capacity (Ics)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% of Icu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermomagnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip curve of supplied 63A unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\/C\/K are series options; exact curve not legible\/confirmed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeteropolar \/ polarity-sensitive YCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial source + product markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePV: 1,500; PVn: 300 operations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerating required above 2,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory II \/ III\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN35 standard rail\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5–25mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended copper conductor for 63A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal tightening torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial YCB8-63PV component data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComplete assembly dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo official assembly datasheet located\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComplete assembly weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo official assembly datasheet located\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic transfer function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual mechanical assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual selection between two compatible photovoltaic DC sources\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManual DC source changeover in engineered solar distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC backup-source selection where voltage, current, polarity and earthing are compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial, communication and civil DC systems within verified component ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC isolation and circuit protection as part of a correctly designed system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eNot for AC circuits. Suitability for battery systems, switching under load and any particular earthing arrangement must be confirmed by the system designer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × assembled CNC 2P+2P manual DC changeover device — visible product configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstruction sheet — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail or enclosure — Not Verified \/ not shown\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting accessories — Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload protection through YCB8-63PV breakers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit protection through YCB8-63PV breakers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC circuit isolation through YCB8-63PV breakers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanical source interlocking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolarity-marked terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eNot included or not verified: surge protection (SPD), residual-current protection (RCD\/RCBO), arc-fault protection, remote trip, automatic transfer control or source synchronization.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard \/ mark\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially specified for YCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEU RoHS requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially specified for YCB8-63PV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark visible; CNC provides a YCB8-63PV CE certificate download\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBV \/ CB certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCNC provides YCB8-63PV certificate downloads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGB 14048.11\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarking visible on YC88-00M; complete assembly certification Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified. Confirm the applicable warranty period and terms with ExSolar.pk or the authorized CNC supplier for this exact assembled SKU.\u003c\/span\u003e\u003c\/p\u003e","brand":"CNC","offers":[{"title":"Default Title","offer_id":52536650465560,"sku":null,"price":3150.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_4_54f2d3df-7599-477c-8caf-eafeb50daf88.png?v=1787208564"},{"product_id":"rawl-bolt","title":"8mm Rawl Bolt Sleeve Expansion Anchor","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8mm Rawl Bolt \/ Sleeve Expansion Anchor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Mounting Accessories \/ Fasteners \/ Expansion Anchors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ Mechanical Fastener\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe uploaded reference shows three similar anchors in different sizes. This product record is prepared specifically for the smallest 8mm variant requested by the customer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e8mm Rawl Bolt Sleeve Expansion Anchor\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eAn 8mm sleeve expansion anchor with a hex head, washer, threaded stud and slotted expansion sleeve. Designed for secure mechanical fixing in suitable solid concrete or masonry when selected and installed by a qualified professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe 8mm Rawl Bolt Sleeve Expansion Anchor is a compact mechanical fixing accessory for mounting compatible brackets, supports and structural hardware to an approved solid substrate. Its assembled design combines a hexagonal head, washer, threaded stud, expansion sleeve and expansion end in one convenient unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the anchor is correctly installed and tightened, the sleeve is intended to expand inside the drilled hole and develop mechanical retention. Actual suitability and load performance depend on the substrate, embedment depth, hole preparation, edge distance, spacing, installation torque, material grade and manufacturer approval. These values were not supplied and must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8mm nominal size, as specified by the customer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSleeve expansion anchor design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHexagonal head for tool-operated tightening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated washer visible in the reference design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThreaded stud construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSlotted metal expansion sleeve\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExpansion end for mechanical anchoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePre-assembled, compact fixing format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSilver metallic appearance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for professional mounting work in an approved solid substrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan be considered for compatible solar mounting brackets after structural approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact load capacity and installation torque must be confirmed before use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnchor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSleeve Expansion Anchor \/ Rawl Bolt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHead Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHexagonal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWasher\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded \/ visible in reference design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain Components\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThreaded stud, washer, slotted sleeve and expansion end\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Appearance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilver metallic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSteel Grade\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Coating \/ Plating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Anchor Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Diameter and Pitch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequired Drill Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequired Hole Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Embedment Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensile Load Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShear Load Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproved Substrate Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion Resistance Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePack Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible solar panel mounting brackets, subject to engineering approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar rail and support fixing where the anchor is approved for the substrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBrackets, frames and support hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral residential and commercial mechanical fixing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable solid concrete or masonry applications only after installation parameters are confirmed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDo not use in hollow, cracked, weak or unknown substrates unless the manufacturer or a qualified engineer specifically approves the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × assembled 8mm rawl bolt \/ sleeve expansion anchor: expected from the product format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail pack quantity: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThis is a mechanical fixing accessory and does not provide electrical protection. Any corrosion-protective coating, fire rating or environmental protection classification is Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/p\u003e","brand":"Rawl Bolt","offers":[{"title":"Default Title","offer_id":52552903852312,"sku":null,"price":30.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_6_0c2bca6d-b47d-494f-b54e-e4d88842d5ee.png?v=1787388612"},{"product_id":"rawl-bolt-10mm","title":"10mm Rawl Bolt Sleeve Expansion Anchor","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mm Rawl Bolt \/ Sleeve Expansion Anchor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Mounting Accessories \/ Fasteners \/ Expansion Anchors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ Mechanical Fastener\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe uploaded reference shows three similar anchors in different sizes. This product record is prepared specifically for the middle 10mm variant requested by the customer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e10mm Rawl Bolt Sleeve Expansion Anchor\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eA 10mm sleeve expansion anchor featuring a hexagonal head, washer, threaded stud and slotted expansion sleeve. Intended for secure mechanical fixing in a suitable solid concrete or masonry substrate when selected and installed by a qualified professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe 10mm Rawl Bolt Sleeve Expansion Anchor is a mechanical fixing accessory designed for mounting compatible brackets, supports and structural hardware to an approved solid substrate. Its assembled construction combines a hex head, washer, threaded stud, expansion sleeve and expansion end in one convenient fixing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCorrect tightening is intended to expand the sleeve inside a properly prepared hole and develop mechanical retention. Actual suitability and performance depend on the substrate, embedment depth, hole preparation, spacing, edge distance, installation torque, material grade and manufacturer approval. These technical values were not supplied and must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e10mm nominal size, as specified by the customer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSleeve expansion anchor design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHexagonal head for tool-operated tightening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated washer visible in the reference design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThreaded stud construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSlotted metal expansion sleeve\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExpansion end for mechanical anchoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePre-assembled fixing format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSilver metallic appearance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for professional mounting in an approved solid substrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan be considered for compatible solar mounting brackets after structural approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact load capacity and installation torque must be confirmed before use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnchor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSleeve Expansion Anchor \/ Rawl Bolt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHead Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHexagonal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWasher\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded \/ visible in reference design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain Components\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThreaded stud, washer, slotted sleeve and expansion end\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Appearance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilver metallic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSteel Grade\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Coating \/ Plating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Anchor Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Diameter and Pitch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequired Drill Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequired Hole Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Embedment Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensile Load Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShear Load Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproved Substrate Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion Resistance Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePack Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible solar panel mounting brackets, subject to engineering approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar rail and support fixing where the anchor is approved for the substrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBrackets, frames and support hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral residential and commercial mechanical fixing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable solid concrete or masonry applications only after installation parameters are confirmed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDo not use in hollow, cracked, weak or unknown substrates unless the manufacturer or a qualified engineer specifically approves the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × assembled 10mm rawl bolt \/ sleeve expansion anchor: expected from the product format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail pack quantity: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThis is a mechanical fixing accessory and does not provide electrical protection. Any corrosion-protective coating, fire rating or environmental protection classification is Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/p\u003e","brand":"Rawl Bolt","offers":[{"title":"Default Title","offer_id":52552995635480,"sku":null,"price":50.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_7_9ef95397-c887-4462-b6a2-525771980680.png?v=1787391161"},{"product_id":"12mm-rawl-bolt","title":"12mm Rawl Bolt Sleeve Expansion Anchor","description":"\u003ch1\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12mm Rawl Bolt \/ Sleeve Expansion Anchor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Mounting Accessories \/ Fasteners \/ Expansion Anchors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory \/ Mechanical Fastener\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe uploaded reference shows three similar anchors in different sizes. This product record is prepared specifically for the largest top-left 12mm variant requested by the customer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e12mm Rawl Bolt Sleeve Expansion Anchor\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eA 12mm sleeve expansion anchor featuring a hexagonal head, washer, threaded stud and long slotted expansion sleeve. Intended for secure mechanical fixing in a suitable solid concrete or masonry substrate when selected and installed by a qualified professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe 12mm Rawl Bolt Sleeve Expansion Anchor is a mechanical fixing accessory designed for mounting compatible brackets, supports and structural hardware to an approved solid substrate. Its assembled construction combines a hex head, washer, threaded stud, expansion sleeve and expansion end in one convenient fixing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCorrect tightening is intended to expand the sleeve inside a properly prepared hole and develop mechanical retention. Actual suitability and performance depend on the substrate, embedment depth, hole preparation, spacing, edge distance, installation torque, material grade and manufacturer approval. These technical values were not supplied and must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e12mm nominal size, as specified by the customer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSleeve expansion anchor design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHexagonal head for tool-operated tightening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated washer visible in the reference design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThreaded stud construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLong slotted metal expansion sleeve\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExpansion end for mechanical anchoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePre-assembled fixing format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSilver metallic appearance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for professional mounting in an approved solid substrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan be considered for compatible solar mounting brackets after structural approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact load capacity and installation torque must be confirmed before use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnchor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSleeve Expansion Anchor \/ Rawl Bolt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHead Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHexagonal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWasher\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded \/ visible in reference design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain Components\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThreaded stud, washer, slotted sleeve and expansion end\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Appearance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilver metallic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSteel Grade\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Coating \/ Plating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact Anchor Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Diameter and Pitch\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequired Drill Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRequired Hole Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Embedment Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensile Load Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShear Load Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproved Substrate Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion Resistance Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePack Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible solar panel mounting brackets, subject to engineering approval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar rail and support fixing where the anchor is approved for the substrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBrackets, frames and support hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral residential and commercial mechanical fixing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable solid concrete or masonry applications only after installation parameters are confirmed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDo not use in hollow, cracked, weak or unknown substrates unless the manufacturer or a qualified engineer specifically approves the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × assembled 12mm rawl bolt \/ sleeve expansion anchor: expected from the product format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail pack quantity: Not Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThis is a mechanical fixing accessory and does not provide electrical protection. Any corrosion-protective coating, fire rating or environmental protection classification is Not Verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/p\u003e","brand":"Rawl Bolt","offers":[{"title":"Default Title","offer_id":52553135718680,"sku":null,"price":70.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_8_ebef8c36-9d21-4d02-82b7-776ebfce61ac.png?v=1787393674"},{"product_id":"4mm-joca-xlpo-solar-dc-cable","title":"JOCA 4mm² H1Z2Z2-K XLPO Solar DC Cable","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified Product Data\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJOCA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4mm² single-core photovoltaic solar cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories \/ Solar DC Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH1Z2Z2-K; IEC 62930 \/ EN 50618\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 4.0mm² (12 AWG), Class 5 tinned-copper conductor, XLPO insulation and XLPO outer sheath\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Colors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed \/ Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eNote: The technically correct material abbreviation is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eXLPO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (cross-linked polyolefin), not “XPLO.”\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eJOCA 4mm² H1Z2Z2-K XLPO Solar DC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eJOCA 4mm² single-core photovoltaic cable is designed for 1500V DC solar installations. It uses a flexible Class 5 tinned-copper conductor with halogen-free, electron-beam cross-linked XLPO insulation and outer sheath. The cable is available in red and black and is specified for rooftop, ground-mounted and floating PV applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe JOCA 4mm² solar cable is a purpose-built photovoltaic conductor for dependable DC connections between solar modules, string equipment and inverters. Its 1 × 4.0mm² Class 5 tinned-copper conductor combines flexibility with corrosion resistance, while the double XLPO construction provides robust electrical insulation and environmental protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJOCA specifies this cable for up to 1500V DC and lists compliance with IEC 62930 and EN 50618. The manufacturer also publishes resistance to UV, ozone and hydrolysis, a working-temperature range of -40°C to +90°C, and an expected service life of at least 25 years. Red and black sheath options support clear DC polarity identification during professional solar installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFinal cable sizing, ampacity, connector compatibility, routing and derating must be confirmed by a qualified solar installer according to the project design and applicable electrical codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e4mm² single-core photovoltaic cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eH1Z2Z2-K solar-cable construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated for up to 1500V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible Class 5 tinned-copper conductor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e56 × 0.28mm conductor-strand construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free electron-beam cross-linked XLPO insulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant XLPO outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed and black sheath options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV, ozone and hydrolysis resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWorking-temperature range from -40°C to +90°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with commonly used solar connectors, subject to connector approval and correct crimping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for rooftop, ground-mounted and floating photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially Verified Value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJOCA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-core photovoltaic cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH1Z2Z2-K; IEC 62930 \/ EN 50618\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Cross-Section\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 4.0mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate AWG Equivalent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 AWG (manufacturer table)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass 5 tinned copper, according to EN 60228 and IEC 60228\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e56 × 0.28mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen-free electron-beam cross-linked polyolefin copolymer (XLPO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Nominal Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Sheath\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen-free electron-beam cross-linked XLPO, flame-retardant compound\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSheath Nominal Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSheath Color\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed \/ Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.55mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600\/1000V AC; 1500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5kV AC for 10 minutes or 15kV DC for 10 minutes, at 20 ±0.5°C, without breakdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum DC Conductor Resistance at 20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.09Ω\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-Published Current-Carrying Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55A; final permissible current depends on installation method and derating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Conductor Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120°C for 20,000 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBending Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 × cable diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExpected Service Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥25 years (manufacturer performance claim; not a commercial warranty)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFire Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 60332-1-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSmoke \/ Halogen Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60754-2 \/ EN 60754-2; EN 50525\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWater Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAd8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeather \/ UV Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50289-4-17 \/ EN ISO 4892\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCPR Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCca according to EN 50575\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePack \/ Roll Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified for this ExSolar.pk SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommercial Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential rooftop photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial solar installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial photovoltaic plants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGround-mounted solar arrays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFloating photovoltaic installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-module interconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eString, combiner and inverter-side DC cabling, where approved by the system designer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eJOCA 4mm² solar cable in the selected red or black color\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupplied length \/ roll size: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnectors, lugs, tools and accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified \/ not stated as included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOzone resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHydrolysis resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeather resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAd8 water performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free insulation and sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant outer-sheath compound\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-smoke \/ halogen-performance standards listed by the manufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh- and low-temperature performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62930\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50618\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN \/ IEC 60228 Class 5 conductor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL (listed by manufacturer)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 60332-1-2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50575 CPR Cca\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC \/ EN 60754-2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAd8 water performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e JOCA publishes an expected service life of at least 25 years, but an official commercial warranty term for the specific ExSolar.pk SKU was not verified. Expected service life must not be presented as a warranty.\u003c\/span\u003e\u003c\/p\u003e","brand":"JOCA XLPO","offers":[{"title":"Default Title","offer_id":52559838249240,"sku":null,"price":26999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_9_478cdf35-f6df-4986-859a-4e1d74d983cf.png?v=1787549794"},{"product_id":"joca-6mm-xlpo-solar-cable-90-meter-coil","title":"JOCA 6mm² H1Z2Z2-K XLPO Solar Cable — 90 Meter Coil","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eProduct Data\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJOCA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6mm² single-core photovoltaic solar cable, 90-meter retail coil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories \/ Solar DC Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH1Z2Z2-K; IEC 62930 \/ EN 50618\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 6.0mm² (10 AWG), Class 5 tinned-copper conductor, XLPO insulation and XLPO outer sheath\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed \/ Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRetail Coil Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 meters — supplied SKU detail; not verified on JOCA's official packing table\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003eThe technically correct material abbreviation is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eXLPO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (cross-linked polyolefin), not “XPLO.”\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eJOCA 6mm² H1Z2Z2-K XLPO Solar Cable — 90 Meter Coil\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eJOCA 6mm² single-core photovoltaic cable is designed for 1500V DC solar installations. It features a flexible Class 5 tinned-copper conductor with halogen-free, electron-beam cross-linked XLPO insulation and outer sheath. This ExSolar.pk SKU is offered as a 90-meter red or black coil.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe JOCA 6mm² solar cable provides a robust DC cabling solution for photovoltaic module, string, combiner and inverter connections. Its flexible 1 × 6.0mm² Class 5 tinned-copper conductor supports reliable installation and corrosion resistance, while the double XLPO construction provides durable electrical insulation and environmental protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJOCA specifies the cable for up to 1500V DC and publishes compliance with IEC 62930 and EN 50618. The official manufacturer data lists resistance to UV, ozone and hydrolysis, a working-temperature range from -40°C to +90°C, and an expected service life of at least 25 years. Red and black sheath options assist with polarity identification in professionally designed PV systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis listing identifies the retail package as a 90-meter coil based on the supplied ExSolar.pk SKU information. JOCA's official packing table lists other standard pack lengths, so the 90-meter pack length should be confirmed against local stock before publishing inventory-sensitive content.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCable sizing, ampacity, connector selection, routing and derating must be confirmed by a qualified solar installer according to the project design and applicable electrical codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6mm² single-core photovoltaic cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-meter retail coil supplied for this SKU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eH1Z2Z2-K solar-cable construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated for up to 1500V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible Class 5 tinned-copper conductor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e78 × 0.29mm conductor-strand construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free electron-beam cross-linked XLPO insulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant XLPO outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed and black color variants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV, ozone and hydrolysis resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWorking-temperature range from -40°C to +90°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for rooftop, ground-mounted and floating photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficially Verified Value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJOCA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-core photovoltaic cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard \/ Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH1Z2Z2-K; IEC 62930 \/ EN 50618\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Cross-Section\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 6.0mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate AWG Equivalent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 AWG (manufacturer table)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass 5 tinned copper according to EN 60228 and IEC 60228\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e78 × 0.29mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen-free electron-beam cross-linked polyolefin copolymer (XLPO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Nominal Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Sheath\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen-free electron-beam cross-linked XLPO, flame-retardant compound\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSheath Nominal Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSheath Color\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed \/ Black\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.15mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600\/1000V AC; 1500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5kV AC for 10 minutes or 15kV DC for 10 minutes at 20 ±0.5°C, without breakdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum DC Conductor Resistance at 20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.39Ω\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer-Published Current-Carrying Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70A; final permissible current depends on installation method and derating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Conductor Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120°C for 20,000 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBending Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 × cable diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExpected Service Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥25 years (manufacturer performance claim; not a commercial warranty)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFire Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 60332-1-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSmoke \/ Halogen Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60754-2 \/ EN 60754-2; EN 50525\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWater Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAd8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeather \/ UV Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50289-4-17 \/ EN ISO 4892\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCPR Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCca according to EN 50575\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRetail Coil Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 meters — supplied SKU detail; official manufacturer verification not found\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommercial Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential rooftop photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial solar installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial photovoltaic plants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGround-mounted solar arrays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFloating photovoltaic systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-module interconnection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eString, combiner and inverter-side DC wiring where approved by the system designer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAgricultural solar and pumping systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × JOCA 6mm² solar cable coil in the selected red or black color\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail length: 90 meters, based on supplied SKU information\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnectors, lugs, crimp tools and accessories: Not Verified \/ not stated as included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOzone resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHydrolysis resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeather resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAd8 water performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free insulation and sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant outer-sheath compound\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-smoke \/ halogen-performance standards listed by JOCA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh- and low-temperature performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62930\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50618\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN \/ IEC 60228 Class 5 conductor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL (listed by manufacturer)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 60332-1-2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 50575 CPR Cca\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC \/ EN 60754-2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAd8 water performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e JOCA publishes an expected service life of at least 25 years, but an official commercial warranty applicable to this 90-meter Pakistan retail SKU was not verified. Expected service life must not be presented as a warranty.\u003c\/span\u003e\u003c\/p\u003e","brand":"JOCA XLPO","offers":[{"title":"Default Title","offer_id":52559886975256,"sku":null,"price":35999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/04-transparent-black-reel.png?v=1787553974"},{"product_id":"fast-cables-4mm-dc-solar-cable-90m-seller-coil","title":"Fast Cables FastGreen 4mm² 1500V DC Solar Cable — 90m Seller Coil","description":"\u003cp\u003e\u003cspan\u003ePrepared for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eExSolar.pk\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eResearch date: 24 August 2026\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePack-size disclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e “90 Meter Coil” is the seller-supplied SKU description provided by the user. Fast Cables’ official 4mm² technical data sheet specifies a manufacturing cable length of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000 m ±5%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and does not confirm a factory-packed 90 m coil. The 90 m pack size is therefore \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified by the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFast Cables Limited\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFastGreen H1Z2Z2-K Photovoltaic Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 4mm² Flexible TCU \/ XLPO \/ XLPO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories → PV DC Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-grid, hybrid and off-grid photovoltaic systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFastGreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer model\/code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo separate commercial model number published; cable marking is H1Z2Z2-K 1×4mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeller pack\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e90-meter coil — manufacturer verification: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eIdentification is based on the official \u003c\/span\u003e\u003ca href=\"https:\/\/fast-cables.com\/wp-content\/uploads\/2026\/06\/Solar-Cable-1x4mm%C2%B2-Flexible-TCU-XLPO-XLPO-1500V-DC-BS-EN-50618.pdf\"\u003e\u003cspan\u003eFast Cables 1×4mm² technical data sheet\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/fast-cables.com\/wp-content\/uploads\/2023\/12\/Solar-Cables_compressed.pdf\"\u003e\u003cspan\u003eFastGreen Solar Cables catalogue\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFast Cables FastGreen 4mm² 1500V DC Solar Cable — 90m Seller Coil\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFast Cables FastGreen 1×4mm² H1Z2Z2-K photovoltaic cable uses a flexible Class 5 tinned-copper conductor with double XLPO insulation for 1500V DC solar installations. This ExSolar.pk SKU is supplied as a 90-meter seller coil; the 90m packing length is not confirmed as a Fast Cables factory pack.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for photovoltaic power connections, the FastGreen 4mm² solar cable combines a flexible Class 5 tinned-copper conductor with XLPO insulation and an XLPO outer sheath. The official Fast Cables data sheet rates the cable at 1500\/1500V DC and 1000\/1000V AC, with a maximum continuous conductor temperature of 90°C and short-circuit conductor temperature of 250°C for five seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts single-core, double-insulated construction is intended for module interconnections, module-to-inverter wiring and other fixed solar DC cable routes. The official FastGreen catalogue identifies UV resistance, weather resistance, flame retardance, halogen-free construction and low-smoke performance. The cable complies with BS EN 50618 and IEC 60228, while the published cable marking is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFAST CABLES LTD. H1Z2Z2-K 1X4mm² PHOTOVOLTAIC CABLE 1500 V (DC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis listing is for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e90-meter seller-supplied coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Fast Cables’ official TDS lists 1000 m ±5% as the manufacturing cable length, so buyers requiring original factory packing should confirm packaging and traceability with ExSolar.pk before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × 4mm² single-core photovoltaic cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eH1Z2Z2-K solar cable designation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible Class 5 tinned-copper conductor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDouble XLPO construction: XLPO insulation and XLPO outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated 1500\/1500V DC and 1000\/1000V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum continuous conductor temperature: 90°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum short-circuit conductor temperature: 250°C for 5 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV- and weather-resistant outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant, halogen-free construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMinimum bending radius: 6 × overall cable diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBS EN 50618 and IEC 60228 compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeller-supplied 90-meter coil; factory pack status \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial value \/ status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFastGreen H1Z2Z2-K photovoltaic cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of conductors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal conductor area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTinned copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexible Class 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum individual wire size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXLPO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal insulation thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.70 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation colour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter-sheath material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXLPO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal sheath thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial TDS sheath colour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalogue sheath colour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage, DC Uo\/U\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500\/1500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage, AC Uo\/U\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000\/1000V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum continuous conductor temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum short-circuit conductor temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250°C for 5 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePublished operating-temperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-temperature endurance claim\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 120°C for 20,000 hours maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpper-limit overall diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate cable weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 kg\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum DC conductor resistance at 20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.09 Ω\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum insulation resistance at 20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e580 MΩ·km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent capacity: single cable in free air at 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent capacity: single cable on surface at 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e52 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent capacity: two loaded cables touching on surface at 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e44 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum bending radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC high-voltage test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5kV AC for 5 minutes; no breakdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC high-voltage test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15kV DC for 5 minutes; no breakdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturing cable length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 m ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThis SKU’s coil length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e90 m — user\/seller supplied; manufacturer verification \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFinished 90m-coil dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFinished 90m-coil gross\/net weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of manufacture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePakistan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eCurrent capacities are published test\/reference values and are not a substitute for installation design. Actual allowable current depends on ambient temperature, grouping, routing, connectors, system voltage drop and applicable electrical codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-module interconnections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV module junction box connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar array to combiner-box wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombiner box to inverter DC wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential on-grid solar systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential and commercial hybrid systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff-grid PV systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and industrial rooftop PV installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAgricultural solar and pumping installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFixed outdoor DC cable routes designed for H1Z2Z2-K cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Fast Cables 4mm² solar cable, seller-supplied 90m coil\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCable colour: red or black, subject to the selected variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMC4 connectors, lugs, glands, labels and installation accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified \/ not included unless separately stated by ExSolar.pk\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFast Cables factory-original 90m retail packaging: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV-resistant outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeather-resistant construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant XLPO insulation and sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-smoke performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTinned-copper conductor for improved corrosion resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDouble-insulated photovoltaic cable construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-temperature resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCold flexibility down to the published −40°C operating limit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBS EN 50618\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified on official TDS and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60228\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified on official TDS and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60332-1 flame performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61034 \/ EN 61034-2 smoke emission\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50395 and EN 50396\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV Austria certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClaimed in official Fast Cables catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE marking for this exact SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS for this exact SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFast Cables publishes a limited warranty covering defects in material and workmanship, subject to correct handling, storage, transport, installation, operation, maintenance, purchase through an authorised distributor\/dealer and proof of purchase. The official policy does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot state a numeric warranty duration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this exact solar cable; therefore the warranty period is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. See the \u003c\/span\u003e\u003ca href=\"https:\/\/fast-cables.com\/wp-content\/uploads\/2025\/03\/Warranty-Policy-Fast-Cables.pdf\"\u003e\u003cspan\u003eofficial Fast Cables warranty policy\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fast Cable","offers":[{"title":"Default Title","offer_id":52560087417112,"sku":null,"price":29500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_11_4a9c2b3d-be16-4633-bfa0-732a87fed866.png?v=1787555591"},{"product_id":"fast-cables-6mm-dc-solar-cable-90m-seller-coil","title":"Fast Cables FastGreen 6mm² 1500V DC Solar Cable — 90m Seller Coil","description":"\u003cp\u003e\u003cspan\u003ePrepared for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eExSolar.pk\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eResearch date: 24 August 2026\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePack-size disclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e “90 Meter Coil” is the seller-supplied SKU description provided by the user. Fast Cables’ official 6mm² technical data sheet specifies a manufacturing cable length of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000 m ±5%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and does not confirm a factory-packed 90 m coil. The 90 m pack size is therefore \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified by the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eColour disclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The exact official 1×6mm² TDS specifies a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eblack outer sheath\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A red coil is shown as a seller-variant visual; manufacturer confirmation of the red 6mm² variant is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eVerified identification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFast Cables Limited\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFastGreen H1Z2Z2-K Photovoltaic Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExact construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 6mm² Flexible TCU \/ XLPO \/ XLPO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories → PV DC Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-grid, hybrid and off-grid photovoltaic systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFastGreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer model\/code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo separate commercial model number published; cable marking is H1Z2Z2-K 1×6mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeller pack\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e90-meter coil — manufacturer verification: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eIdentification is based on the official \u003c\/span\u003e\u003ca href=\"https:\/\/fast-cables.com\/wp-content\/uploads\/2026\/06\/Solar-Cable-1x6mm%C2%B2-Flexible-TCU-XLPO-XLPO-1500V-DC-BS-EN-50618.pdf\"\u003e\u003cspan\u003eFast Cables 1×6mm² technical data sheet\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/fast-cables.com\/wp-content\/uploads\/2023\/12\/Solar-Cables_compressed.pdf\"\u003e\u003cspan\u003eFastGreen Solar Cables catalogue\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFast Cables FastGreen 6mm² 1500V DC Solar Cable — 90m Seller Coil\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFast Cables FastGreen 1×6mm² H1Z2Z2-K photovoltaic cable uses a flexible Class 5 tinned-copper conductor with double XLPO insulation for 1500V DC solar installations. This ExSolar.pk SKU is supplied as a 90-meter seller coil; the 90m packing length is not confirmed as a Fast Cables factory pack.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for photovoltaic power connections, the FastGreen 6mm² solar cable combines a flexible Class 5 tinned-copper conductor with XLPO insulation and an XLPO outer sheath. The official Fast Cables data sheet rates the cable at 1500\/1500V DC and 1000\/1000V AC, with a maximum continuous conductor temperature of 90°C and short-circuit conductor temperature of 250°C for five seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts single-core, double-insulated construction is intended for module interconnections, module-to-inverter wiring and other fixed solar DC cable routes. The official FastGreen catalogue identifies UV resistance, weather resistance, flame retardance, halogen-free construction and low-smoke performance. The cable complies with BS EN 50618 and IEC 60228, while the published cable marking is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFAST CABLES LTD. H1Z2Z2-K 1X6mm² PHOTOVOLTAIC CABLE 1500 V (DC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis listing is for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e90-meter seller-supplied coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Fast Cables’ official TDS lists 1000 m ±5% as the manufacturing cable length, so buyers requiring original factory packing should confirm packaging and traceability with ExSolar.pk before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × 6mm² single-core photovoltaic cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eH1Z2Z2-K solar cable designation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible Class 5 tinned-copper conductor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDouble XLPO construction: XLPO insulation and XLPO outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRated 1500\/1500V DC and 1000\/1000V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum continuous conductor temperature: 90°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum short-circuit conductor temperature: 250°C for 5 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV- and weather-resistant outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant, halogen-free construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMinimum bending radius: 6 × overall cable diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBS EN 50618 and IEC 60228 compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeller-supplied 90-meter coil; factory pack status \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial value \/ status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFastGreen H1Z2Z2-K photovoltaic cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of conductors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal conductor area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTinned copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexible Class 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum individual wire size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXLPO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal insulation thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.70 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation colour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter-sheath material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXLPO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal sheath thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial TDS sheath colour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalogue sheath colour\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage, DC Uo\/U\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500\/1500V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated voltage, AC Uo\/U\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000\/1000V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum continuous conductor temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum short-circuit conductor temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250°C for 5 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePublished operating-temperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−40°C to +90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-temperature endurance claim\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 120°C for 20,000 hours maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpper-limit overall diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate cable weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e86 kg\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum DC conductor resistance at 20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.39 Ω\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum insulation resistance at 20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 MΩ·km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent capacity: single cable in free air at 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent capacity: single cable on surface at 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e67 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent capacity: two loaded cables touching on surface at 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e57 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum bending radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC high-voltage test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5kV AC for 5 minutes; no breakdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC high-voltage test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15kV DC for 5 minutes; no breakdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOfficial manufacturing cable length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 m ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThis SKU’s coil length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e90 m — user\/seller supplied; manufacturer verification \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFinished 90m-coil dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFinished 90m-coil gross\/net weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of manufacture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePakistan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eCurrent capacities are published test\/reference values and are not a substitute for installation design. Actual allowable current depends on ambient temperature, grouping, routing, connectors, system voltage drop and applicable electrical codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-module interconnections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV module junction box connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar array to combiner-box wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombiner box to inverter DC wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential on-grid solar systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential and commercial hybrid systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff-grid PV systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and industrial rooftop PV installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAgricultural solar and pumping installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFixed outdoor DC cable routes designed for H1Z2Z2-K cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Fast Cables 6mm² solar cable, seller-supplied 90m coil\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCable colour: black is verified on the exact official TDS; red seller variant is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified by the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMC4 connectors, lugs, glands, labels and installation accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified \/ not included unless separately stated by ExSolar.pk\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFast Cables factory-original 90m retail packaging: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV-resistant outer sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeather-resistant construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame-retardant XLPO insulation and sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-smoke performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTinned-copper conductor for improved corrosion resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDouble-insulated photovoltaic cable construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-temperature resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCold flexibility down to the published −40°C operating limit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications and Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBS EN 50618\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified on official TDS and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60228\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified on official TDS and catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 62930\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eListed on the official Fast Cables Solar Cables product page\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60332-1 flame performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61034 \/ EN 61034-2 smoke emission\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50395 and EN 50396\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified in official catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV Austria certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClaimed in official Fast Cables catalogue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE marking for this exact SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS for this exact SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFast Cables publishes a limited warranty covering defects in material and workmanship, subject to correct handling, storage, transport, installation, operation, maintenance, purchase through an authorised distributor\/dealer and proof of purchase. The official policy does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot state a numeric warranty duration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this exact solar cable; therefore the warranty period is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. See the \u003c\/span\u003e\u003ca href=\"https:\/\/fast-cables.com\/wp-content\/uploads\/2025\/03\/Warranty-Policy-Fast-Cables.pdf\"\u003e\u003cspan\u003eofficial Fast Cables warranty policy\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fast Cable","offers":[{"title":"Default Title","offer_id":52560273178904,"sku":null,"price":38999.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_12_5d73baf5-1ea3-4b59-8187-2d886ec5f221.png?v=1787556552"},{"product_id":"premium-cable-4mm-dc-solar-wire-90m-coil","title":"Premium Cable 4mm DC Solar Wire — 90m Coil","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eResult\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4mm DC Solar Wire, 90-Meter Seller Coil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Cable — user provided; official manufacturer identity Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories \/ PV \u0026amp; DC Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed or black cable coil shown; exact sales configuration Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied primary image visibly shows red and black coils labelled \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“4mm DC SOLAR WIRE.”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 90-meter length and “Premium Cable” name were provided by the seller\/user. No matching official manufacturer product page, datasheet, manual, or catalogue could be verified. The third supplied reference carries an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eELECKTOR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e logo and was therefore excluded as technical evidence for this product.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePremium Cable 4mm DC Solar Wire — 90m Coil\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSeller-described 4mm DC solar wire supplied as a 90-meter coil, with red and black colour options shown for organised solar-system wiring. Manufacturer identity and all electrical, material, environmental, certification and warranty ratings remain \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Premium Cable 4mm DC Solar Wire is presented as a coiled wiring solution for photovoltaic and other low-voltage DC solar connections. Its red and black colour options can support clear cable-route and polarity planning when assigned correctly by a qualified installer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe seller describes this product as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4mm², 90-meter coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. However, an exact official manufacturer match was not found. Important selection data—including conductor material, insulation construction, voltage rating, current-carrying capacity, temperature range, UV and weather resistance, flame performance, standards, certifications and warranty—must be verified from the actual coil printing, packaging, batch documentation or supplier certificate before purchase or installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor safe system design, cable sizing must be based on system voltage, operating current, installation method, ambient temperature, grouping, route length and allowable voltage drop. Installation and termination should be completed by a qualified solar electrician using compatible connectors, tools and external circuit protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeller-described \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4mm²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e DC solar wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeller-described \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e90-meter coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed and black cable colours are shown in the supplied images.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCoil format supports organised storage, transport and measured cutting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended product category: PV \/ DC solar wiring accessory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed and black options can support installer-assigned polarity identification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupplied imagery visibly carries a “4mm DC SOLAR WIRE” label.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact manufacturer and model number: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConductor material and strand construction: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInsulation, voltage rating, current capacity and standards: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarranty and certified service life: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Cable — user provided; official identity Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Solar Wire \/ PV Cable Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Conductor Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4mm² — seller provided \/ visible label\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoil Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 meters — seller provided\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Colours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed and black shown; exact option or pair configuration Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Cores\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Class \/ Strand Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Sheath Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated AC Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated DC Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum System Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent-Carrying Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-Circuit Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bending Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUV Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOzone \/ Weather Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWater \/ Moisture Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlame \/ Fire Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen \/ Smoke Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar panel string wiring, subject to verified cable ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV array to combiner-box routing, subject to system design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombiner box to inverter DC routing, subject to verified voltage and current limits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial solar installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAgricultural solar systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral low-voltage DC solar cabling where the verified specification is suitable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Application suitability is not established by the images alone. A qualified installer must verify the actual cable marking and technical documentation before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × 90-meter cable coil in the selected colour — seller provided\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed\/black pair inclusion: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnectors, lugs, glands and installation accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified \/ not shown\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis is a passive cable product and does not provide active electrical protection. The following cable-protection properties are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOzone resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWater or moisture resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame retardance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDouble insulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAbrasion resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOil or chemical resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit temperature capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe completed circuit requires correctly selected external DC isolation, overcurrent protection, surge protection, earthing and compatible connectors according to the system design and applicable local requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 62930\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50618 \/ H1Z2Z2-K\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60332\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eISO 9001 Manufacturer Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No official manufacturer warranty document or product warranty page was located for the exact item.\u003c\/span\u003e\u003c\/p\u003e","brand":"Premium Cable","offers":[{"title":"Default Title","offer_id":52560297754904,"sku":null,"price":22500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_13_159f84ec-46a9-4c9e-a100-832a72309217.png?v=1787557590"},{"product_id":"premium-cable-6mm-dc-solar-wire-90m-coil","title":"Premium Cable 6mm DC Solar Wire — 90m Coil","description":"\u003ch2\u003e\u003cspan\u003eProduct Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eField\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eResult\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6mm DC Solar Wire, 90-Meter Seller Coil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Cable — user provided; official manufacturer identity Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolar Accessories \/ PV \u0026amp; DC Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed or black cable coil shown; exact sales configuration Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries \/ Generation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe product name, 6mm size and 90-meter length were provided by the seller\/user. The supplied images show generic red and black cable coils, but no matching official manufacturer identity, model number, product page, datasheet, manual or catalogue could be verified. The exposed strands visible in one reference image are not accepted as manufacturer evidence for conductor material.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePremium Cable 6mm DC Solar Wire — 90m Coil\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eShort Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSeller-described 6mm DC solar wire supplied as a 90-meter coil, with red and black colour options shown for organised solar-system wiring. Manufacturer identity and all electrical, material, environmental, certification and warranty ratings remain \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and must be confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLong Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Premium Cable 6mm DC Solar Wire is presented as a coiled wiring solution for photovoltaic and other low-voltage DC solar connections. Its red and black colour options can support clear cable-route and polarity planning when assigned correctly by a qualified installer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe seller describes this product as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6mm², 90-meter coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. However, an exact official manufacturer match was not found. Important selection data—including conductor material, insulation construction, voltage rating, current-carrying capacity, temperature range, UV and weather resistance, flame performance, standards, certifications and warranty—must be verified from the actual coil printing, packaging, batch documentation or supplier certificate before purchase or installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor safe system design, cable sizing must be based on system voltage, operating current, installation method, ambient temperature, grouping, route length and allowable voltage drop. Installation and termination should be completed by a qualified solar electrician using compatible connectors, tools and external circuit protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeller-described \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6mm²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e DC solar wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeller-described \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e90-meter coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed and black cable colours are shown in the supplied images.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCoil format supports organised storage, transport and measured cutting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended product category: PV \/ DC solar wiring accessory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed and black options can support installer-assigned polarity identification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact manufacturer and model number: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConductor material and strand construction: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInsulation, voltage rating and current capacity: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplicable standards and certifications: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarranty and certified service life: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Cable — user provided; official identity Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Solar Wire \/ PV Cable Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Conductor Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6mm² — seller provided\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoil Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 meters — seller provided\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Colours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed and black shown; exact option or pair configuration Not Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Cores\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Class \/ Strand Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Sheath Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated AC Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated DC Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum System Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent-Carrying Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-Circuit Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bending Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUV Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOzone \/ Weather Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWater \/ Moisture Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlame \/ Fire Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen \/ Smoke Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar panel string wiring, subject to verified cable ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePV array to combiner-box routing, subject to system design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombiner box to inverter DC routing, subject to verified voltage and current limits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential solar installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial solar installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAgricultural solar systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGeneral low-voltage DC solar cabling where the verified specification is suitable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Application suitability is not established by the images alone. A qualified installer must verify the actual cable marking and technical documentation before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBox Contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × 90-meter cable coil in the selected colour — seller provided\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRed\/black pair inclusion: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnectors, lugs, glands and installation accessories: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified \/ not shown\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProtection Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis is a passive cable product and does not provide active electrical protection. The following cable-protection properties are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOzone resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWater or moisture resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame retardance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHalogen-free construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDouble insulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAbrasion resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOil or chemical resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit temperature capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe completed circuit requires correctly selected external DC isolation, overcurrent protection, surge protection, earthing and compatible connectors according to the system design and applicable local requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 62930\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50618 \/ H1Z2Z2-K\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60332\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eISO 9001 Manufacturer Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot Verified.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No official manufacturer warranty document or product warranty page was located for the exact item.\u003c\/span\u003e\u003c\/p\u003e","brand":"Premium Cable","offers":[{"title":"Default Title","offer_id":52560423616792,"sku":null,"price":28500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/files\/01-premium-marketing-banner_14_29473560-d85c-4bce-871d-9bff50961485.png?v=1787559022"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/3368\/5016\/collections\/ChatGPT_Image_Aug_5_2026_02_56_49_PM.png?v=1785924111","url":"https:\/\/exsolar.pk\/collections\/solar-accessories.oembed","provider":"EXSOLAR.PK","version":"1.0","type":"link"}